WODF-1WM
Installation &
Operation Manual
WODF-1WM Series
CWBF-1WM Series
Outdoor Drinking Fountain
Outdoor Bottle Filler
Wall Mounted units
Table of Contents
Pre-Installation Information .....................................3
Physical / Rough-in Dimensions .............................4
Required Installation Supplies ................................6
Parts List and Exploded-view Drawings .................7
Hardware Identifi cation ..........................................9
Installation Instructions .............................................
Step 1: Fixture Installation ...............................10
Step 2A: Adjusting Drinking Spout Flow ..........11
Step 2B: Battery Operated Infrared Sensor
Startup ...............................................11
Care and Maintenance .........................................12
Troubleshooting ........................................................
Fixture Plumbing ...............................................13
Infrared Sensor .................................................14
Drawings ...................................................................
Pushbutton Details ...........................................15
Warranty ...............................................................16
CWBF-1WM
Willoughby Industries, Inc.
5105 West 78th Street
Indianapolis, IN 46268
Toll Free: (800) 428-4065
Local: (317) 875-0830
Fax: (317) 875-0837
www.willoughby-ind.com
Rev. 6/2015
MADE IN THE U.S.A.

Wall Mounted- Outdoor Drinking Fountain / Bottle Filler
WODF-1WM Series / CWBF-1WM Series
(Page intentionally left blank)
Installation & Operation Manual
Willoughby Industries, Inc. TOLL FREE (800) 428-4065 ● LOCAL (317) 875-0830 ● FAX (317) 875-0837
Page 2Rev. 6/2015 www.willoughby-ind.com

Wall Mounted- Outdoor Drinking Fountain / Bottle Filler
WODF-1WM Series / CWBF-1WM Series
Installation & Operation Manual
Pre-Installation Information
Installation notice!
Check Rough-In location PRIOR to installation
Flush lines thoroughly PRIOR to hook-up
When installing the Willoughby Industries' WODF-1WM Series drinking fountain system or
CWBF-1WM Series bottle fi ller system:
Before Step 1 of the installation instructions, ensure that rough-ins are in the correct location.
The valve assembly, including the spray head, MUST NOT BE connected until after all lines have
been fl ushed to remove the small particles of debris that are inherent with new construction projects
and all chemicals that are used in fl ushing are purged from the system.
Chemicals used in fl ushing plumbing systems can attack the internal components of the valve and
spray head and severely damage them, so any fl ushing of the system must be followed by a full
fl ushing with pure water to clear any harsh chemicals remaining in the system. Debris in the system if
allowed to enter the valve assembly and spray head can cause poor performance or outright failure.
Again DO NOT attempt to connect the valve assembly and spray head until after all fl ushing is
complete and pure water is the only media that will be passing through the system. Damage to the
valve assembly or spray head caused by harsh chemicals or debris will not be covered by the
manufacturer's warranty.
Any fi ttings provided by the installer should be made of plastic to electrically isolate the unit from the
building or connected plumbing system.
The grounding of electric equipment such as telephones, computers, etc, to water lines is a common
procedure. This grounding can cause electrical feedback into a water fountain or similar fi xture,
causing electrolysis, which results in a metallic taste or an increase in the metal content of the water.
This can easily be avoided by using the proper materials as indicated.
Installation notice!
Check Rough-In location PRIOR to installation
Flush lines thoroughly
Willoughby Industries, Inc. TOLL FREE (800) 428-4065 ● LOCAL (317) 875-0830 ● FAX (317) 875-0837
PRIOR to hook-up
Page 3Rev. 6/2015 www.willoughby-ind.com

Wall Mounted- Outdoor Drinking Fountain / Bottle Filler
WODF-1WM Series / CWBF-1WM Series
Installation & Operation Manual
Physical / Rough-in Dimensions- WODF-1WM
Willoughby Industries, Inc. TOLL FREE (800) 428-4065 ● LOCAL (317) 875-0830 ● FAX (317) 875-0837
Page 4Rev. 6/2015 www.willoughby-ind.com

Wall Mounted- Outdoor Drinking Fountain / Bottle Filler
WODF-1WM Series / CWBF-1WM Series
Installation & Operation Manual
Physical / Rough-in Dimensions- CWBF-1WM
Willoughby Industries, Inc. TOLL FREE (800) 428-4065 ● LOCAL (317) 875-0830 ● FAX (317) 875-0837
Page 5Rev. 6/2015 www.willoughby-ind.com