Willoughby WODF-1-PET Operation Manual

WODF-1-PET
Installation &
Operation Manual
WODF-1-PET Series
Outdoor Pet Drinking Fountain
Table of Contents
Pre-Installation Information .....................................3
Physical Dimensions ..............................................4
Rough-In Dimensions .............................................5
Required Installation Supplies ................................6
Hardware Identifi cation Chart .................................7
Installation Instructions .............................................
Step 1: Fixture Installation .................................8
Step 2: Adjusting Drinking Spout Flow ...............9
Care and Maintenance .........................................10
Troubleshooting ....................................................11
Detail Drawings ........................................................
General Dimensions .........................................12
Exploded View w/BOM .....................................13
Rough-in Dimensions .......................................14
Freeze Resistant Valve Installation Detail ........15
Warranty ...............................................................16
Willoughby Industries, Inc.
5105 West 78th Street Indianapolis, IN 46268 Toll Free: (800) 428-4065 Local: (317) 875-0830 Fax: (317) 875-0837 www.willoughby-ind.com
Rev. 10/2016
MADE IN THE U.S.A.
Outdoor Pet Drinking Fountain WODF-1-PET Series
(Page intentionally left blank)
Installation & Operation Manual
Willoughby Industries, Inc. TOLL FREE (800) 428-4065 LOCAL (317) 875-0830 FAX (317) 875-0837
Page 2Rev. 10/2016 www.willoughby-ind.com
Outdoor Pet Drinking Fountain WODF-1-PET Series
Installation & Operation Manual
Pre-Installation Information
Installation notice!
Check Rough-In location PRIOR to installation
Flush lines thoroughly PRIOR to hook-up
When installing the Willoughby Industries' WODF-1-PET Series fountain system: Before Step 1 of the installation instructions, ensure that rough-ins are in the correct location. The valve assembly, including the spray head, MUST NOT BE connected until after all lines have
been fl ushed to remove the small particles of debris that are inherent with new construction projects and all chemicals that are used in fl ushing are purged from the system.
Chemicals used in fl ushing plumbing systems can attack the internal components of the valve and spray head and severely damage them, so any fl ushing of the system must be followed by a full ushing with pure water to clear any harsh chemicals remaining in the system. Debris in the system if allowed to enter the valve assembly and spray head can cause poor performance or outright failure.
Again DO NOT attempt to connect the valve assembly and spray head until after all fl ushing is complete and pure water is the only media that will be passing through the system. Damage to the valve assembly or spray head caused by harsh chemicals or debris will not be covered by the manufacturer's warranty.
Any fi ttings provided by the installer should be made of plastic to electrically isolate the unit from the building or connected plumbing system.
The grounding of electric equipment such as telephones, computers, etc, to water lines is a common procedure. This grounding can cause electrical feedback into a water fountain or similar fi xture, causing electrolysis, which results in a metallic taste or an increase in the metal content of the water. This can easily be avoided by using the proper materials as indicated.
Installation notice!
Check Rough-In location PRIOR to installation
Flush lines thoroughly
Willoughby Industries, Inc. TOLL FREE (800) 428-4065 LOCAL (317) 875-0830 FAX (317) 875-0837
PRIOR to hook-up
Page 3Rev. 10/2016 www.willoughby-ind.com
Outdoor Pet Drinking Fountain WODF-1-PET Series
Installation & Operation Manual
Physical Dimensions- WODF-1-PET
12-1/2"
BOLT CIRCLE
9/16" THRU ALL4X
14-1/2" 4-1/4"
15-7/8"
3-13/16"
9-1/2"
7"
4-3/8"
10-3/4"
Willoughby Industries, Inc. TOLL FREE (800) 428-4065 LOCAL (317) 875-0830 FAX (317) 875-0837
Page 4Rev. 10/2016 www.willoughby-ind.com
Outdoor Pet Drinking Fountain WODF-1-PET Series
Installation & Operation Manual
Rough-In Dimensions WODF-1-PET
14-1/2"
4X 9/16" THRU ALL
12-1/2"
BOLT CIRCLE
NOTE: UNIT MUST BE DISCONNECTED AND DRAINED DURING WINTERIZATION, PER THE FOLLOWING RECOMMENDED PRACTICES:
SHUT OFF WATER SUPPLY TO FIXTURE (SUPPLY • STOP AND WATER LINES BY OTHERS) DISCONNECT AND REMOVE IN-LINE FILTER• PRESS AND HOLD PUSHBUTTON FOR 10 SECONDS • TO ALLOW WATER LINES TO DRAIN
VALVE ASSEMBLY DETAIL
#600285 VALVE CARTRIDGE
1/4" TUBE
CONCRETE ANCHORS
4X 1/2"-13 UNC X 4"
(BY OTHERS)
CONCRETE PAD
(BY OTHERS)
1-1/2" PVC COUPLING
(BY OTHERS)
OPEN HUB DRAIN TO BE 1-1/2" IPS
MINIMUM TO A POROUS GRAVEL FILL OR
MAIN SEWER LINE LOCATED BELOW
FROST LINE (BY OTHERS)
NOTE: 3/8" O.D. SUPPLY CONNECTION
SERVICE SHUT-OFF VALVE (BY OTHERS)
WATER SUPPLY LINE (BY OTHERS)
#980632 INLINE STRAINER 1/4" TO 3/8" PRESS LOCK
Willoughby Industries, Inc. TOLL FREE (800) 428-4065 LOCAL (317) 875-0830 FAX (317) 875-0837
Page 5Rev. 10/2016 www.willoughby-ind.com