Willoughby WICS-2222 Installation & Operation Manual

WICS-2222
Installation &
Operation Manual
WICS-2222 Series
Infection Control Sink
Table of Contents
Pre-Installation Information .....................................2
Physical Dimensions ..............................................3
Rough-In Dimensions .............................................4
Mounting Dimensions .............................................5
Checking Contents .................................................6
Required Installation Supplies ................................7
Parts List ................................................................8
Exploded-view Drawing ..........................................9
Hardware Identifi cation ........................................10
Installation Instructions .............................................
Step 1: Pedestal Mounting ...............................11
Step 2: Drain Assembly #320013 ....................12
Step 3: Basin and Pedestal Assembly .............13
Step 4: Final Assembly ....................................14
Adjustable Mixing Valve Installation..................15
Care and Maintenance .........................................16
Warranty ...............................................................17
Willoughby Industries, Inc.
5105 West 78th Street Indianapolis, IN 46268 Toll Free: (800) 428-4065 Local: (317) 875-0830 Fax: (317) 875-0837 www.willoughby-ind.com
Rev. 9/2016
MADE IN THE U.S.A.
Infection Control Sink WICS-2222 Series
Installation & Operation Manual
Pre-Installation Information
Installation notice!
Check Rough-In location PRIOR to installation
Flush lines thoroughly PRIOR to hook-up When installing the Willoughby Industries' WICS-2222 Series lavatory system: Before step 1 of the installation instructions, ensure that rough-ins are in the correct location. The valve assembly, including the spray head, MUST NOT BE connected until after
all lines have been fl ushed to remove the small particles of debris that are inherent with new construction projects and all chemicals that are used in fl ushing are purged from the system.
Chemicals used in fl ushing plumbing systems can attack the internal components of the valve and spray head and severely damage them, so any fl ushing of the system must be followed by a full fl ushing with pure water to clear any harsh chemicals remaining in the system. Debris in the system if allowed to enter the valve assembly and spray head can cause poor performance or outright failure.
Again DO NOT attempt to connect the valve assembly and spray head until after all ushing is complete and pure water is the only media that will be passing through the system. Damage to the valve assembly or spray head caused by harsh chemicals or debris will not be covered by the manufacturer's warranty.
Installation notice!
Check Rough-In location PRIOR to installation
Flush lines thoroughly PRIOR to hook-up
Willoughby Industries, Inc. TOLL FREE (800) 428-4065 LOCAL (317) 875-0830 FAX (317) 875-0837
Page 2Rev. 9/2016 www.willoughby-ind.com
Infection Control Sink WICS-2222 Series
Installation & Operation Manual
Physical Dimensions- WICS-2222
Willoughby Industries, Inc. TOLL FREE (800) 428-4065 LOCAL (317) 875-0830 FAX (317) 875-0837
Page 3Rev. 9/2016 www.willoughby-ind.com
Infection Control Sink WICS-2222 Series
Installation & Operation Manual
Rough-In Dimensions- WICS-2222
NOTE:
FOR INFRARED UNITS ONLY 110V GFCI REQ'D (BY OTHERS) CONSULT LOCAL ELEC. CODES PROVIDE 1" SPACE BETWEEN PERIMETEROF GFCI AND FIXTURE BACKPLATE
33 3/4" AFF
(34 MAX ADA)
1/2" HOT & COLD
WATER SUPPLIES
(BY OTHERS)
1 1/2" WASTE
(TRAP BY OTHERS)
FINISHED FLOOR
3"
C
L
1 1/2"
28 5/8"
29 1/2"
C
L
1"
"Z" CLIP
20.375
Willoughby Industries, Inc. TOLL FREE (800) 428-4065 LOCAL (317) 875-0830 FAX (317) 875-0837
Page 4Rev. 9/2016 www.willoughby-ind.com
Infection Control Sink WICS-2222 Series
Installation & Operation Manual
Mounting Dimensions- WICS-2222
18-1/4"
13-1/4"
9-1/4"
4"
3-1/2" 6-15/16"
4-9/16"
2-1/2"
15-1/16"
12-9/16"
9-13/16"
Willoughby Industries, Inc. TOLL FREE (800) 428-4065 LOCAL (317) 875-0830 FAX (317) 875-0837
C
L
Page 5Rev. 9/2016 www.willoughby-ind.com
Infection Control Sink WICS-2222 Series
Installation & Operation Manual
Check Contents
Separate all parts from packaging and make sure all parts are accounted for before discarding
any packaging material. If any parts are missing, do not attempt to install the WICS-2222 Infection Control Sink until you obtain the missing parts.
NOTE: Before beginning installation, all supply, drain and waste piping for the WICS-2222 must be completed according to specifi ed rough-ins. If you have not received rough-in details, please contact Willoughby Industries, Inc. (800) 428-4065
 IMPORTANT: These installation instructions cover all of the Willoughby Industries Inc. WICS-2222 Series. Simply omit the steps which do not apply to the model you are installing.
 IMPORTANT: Flush all the water supply lines before making connections.
Willoughby Industries, Inc. TOLL FREE (800) 428-4065 LOCAL (317) 875-0830 FAX (317) 875-0837