ZW30 Smart Switch Manual
FCC/IC
Federal Communications Commission (FCC) Statement
FCC Caution: Any changes or modifications not expressly approved by the party responsible for
compliance could void the user ’s authority to operate this equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is encouraged to
try to correct the interference by one or more of the followingmeasures:
-- Reorient or relocate the receiving antenna.
-- Increase the separation between the equipment and receiver.
-- Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
-- Consult the dealer or an experienced radio/TV technician for help.
IC Caution:
This device complies with Indust ry Canada licence-exempt RSS standard(s). Operation is subject
to the following two conditions: (1) this device may not cause interference, and (2) this device must
accept any interference, including interference that may cause undesired
operation of the device.
Le présent appareil est conforme aux CNR d’Industrie Cana da applica bles aux appareils rad io exempts de licence. L’e xploitation est autoris ée aux
deux conditions suivantes : (1) l’appareil ne doit pas p roduire de brouillage;
(2) l’utilisateur de l’appareil doit accepter tout brouillage radi oélectrique subi, même si le brouillage est susceptible d’en compromett re le fonctionn
ement.
In-wall smart switch
WARRANTY
Show Home Products warrants this product to be free from manufacturing defects for
a period of two years from the original date of consumer purchase. This warranty is limited
to the repair or replacement of this product only and does not extend to consequential or
incidental damage to other products that may be used with this product.
This warranty is in lieu of all other warranties, expressed or implied. Some states do not
allow limitations on how long an implied warranty lasts or permit the exclusion or limitation
of incidental or consequential damage, so the above limitations may not apply to you.
This warrant y gives you specific rights, and you may also have other rights which va ry from
state to state. if the unit should prove defective within the warranty period.
WARNING
RISK OF FIRE
SPECIFICATIONS
Model:ZW30
Power: 120 VAC, 60 Hz.
Signal (Frequency): 908.42 MHz.
Maximum Loads: 600W, incandescent,
½ HP Motor or 1800W (15A) Resistive
Range: Up to 100 feet line of sight between the
Wireless Controller and the closest Z-Wave
receiver module.
Operating Temperature Range: 32-104° F (0-40° C)
For indoor use only.
Specifications subject to change without notice
due to continuing product improvement
Website www.ishowlights.com
RISK OF ELECTRICAL SHOCK
RISK OF BURNS
CONTROLLING APPLIANCES:
EXERCISE EXTREME CAUTION WHEN USING Z-WAVE
DEVICES TO CONTROL APPLIANCES. OPERATION
OF THE Z-WAVE DEVICE MAY BE IN A DIFFERENT
ROOM THAN THE CONTROLLED APPLIANCE, ALSO AN
UNINTENTIONAL ACTIVATION MAY OCCUR IF THE WRONG
BUTTON ON THE REMOTE IS PRESSED. Z-WAVE DEVICES
MAY AUTOMATICALLY BE POWERED ON DUE TO TIMED
EVENT PROGRAMMING. DEPENDING UPON THE APPLIANCE, THESE UNATTENDED OR UNINTENTIONAL OPERATIONS COULD POSSIBLY RESULT IN A HAZARDOUS
CONDITION. FOR THESE REASONS, WE RECOMMEND
DO NOT RETURN THIS PRODUCT TO THE STORE
THE FOLLOWING:
DO NOT USE Z-WAVE DEVICES TO CONTROL ELECTRIC
HEATERS OR ANY OTHER APPLIANCES WHICH MAY PRESENT A HAZARDOUS CONDITION DUE TO UNATTENDED OR
UNINTENTIONAL OR AUTOMATIC POWER ON CONTROL.
Getti ng To Know Your New Z- Wave De vice
Turn ON/OFF manually or remotely via the Z-Wave controller
• Can be Included in multiple Groups and Scenes
• May be used in single pole installation or with up to two GE Add-on switches in
3-way or 4-way wiring configurat ions
• Compatible with all incandescent and CFL/LED bulbs
• Interchangeable Paddle switch — White & light almond paddle in package
• Uses a standard, decorat ive-size wall plate for single gang installations
( wall plate not included)
• Blue LED indicates switch location in a dark room
• Z-Wave Certified for simple pairing and integrated home automation
• Screw Terminal Installation — requires wiring connections for Line (Hot), Load,
Neutral, and Ground. Traveler wire required for 3-way or 4-way installation
A.
Top Rocker — (Press &release to turn
Dimmer on,press & hold
increases brightness)
B.
Bottom Rocker — (Press& release
to to turn s witch of f)
C.
Ground (Green/Bare)
D.
Load (Black) E. Line (Black)
F. Traveler (Red/Oth er)
G.Neutral (White)
Single, Dual And Triple Gang Boxes
When instal ling the In-wall Sma rt Dimmer in multi ple gang boxes it may be nece ssary to break off one or both sides of the score d
tabs on the front yoke.This will affect the electrical rating of the switch (see specifications for details)
WARNING — SHOCK HAZARD
Turn OFF the power to the branch circuit for the switch and lighting fixture at
the service panel. A l l wi ring connections must be mad e wit h th e POWER OFF
to avoid personal injury and/or damage to the switch.
This device is intended for installation in accordance with the National Electric
Code and local regulations i n t he U nited States, or t he Canadian Electrical
Code and local regulations in Canada. If you are unsure or
Multi-switch wiri n g
For 3-way installations, please refer to Add-on Switch manual
Single switch wiring
Before you start; you may wish to change the paddle to match
your wall plate or decore. Please proceed to section 5.
1. Shut off power to the circuit at circuit breaker or fuse box.
IMPORTANT! Verify power is OFF to switch box before continuing.
2. Remove wall plate.
3. Remove the switch mounting screws.
4. There are up to five screw terminal s on the switch; t hese are marked
A. LINE (Hot) — Black (connected to power)
B. Neutral — White
C. LOAD — Black (connected to lighting)
D. GROUND — Green/Bare
E. TRAVELER — Red/Other (only in 3-way installations)
Match these screw terminals to the wires connected to the existing switch.
5. Observe Important Wir ing Information
IMPORTANT!: This Dimmer is rated for and intended to
only be used with copper wire.
Wire Gauge Requirements
Use 14 AWG or larger wires suitable for at least 80° C for supplying
Line (HOT), Load,Neutral, Ground and Traveler connections.
Wire strip length:
For attachment to screw terminals: Strip insulation 1" (25mm)
For attachment using the enclosure’s holes: Strip insulation 5/8"(16mm)
UL specifies that the tightening torque for the screws is 12 Kgf-cm.
To Change Color Of The Paddle
This step is optional. Before you start you may want to change the color of the paddle to match your wallplate or decor.
1. Lift the Air Gap tab at the base of the paddle.
2. Push side tabs in on one side and then the other to rele ase paddle. Lift the cover up and off.
3. Simply put the new paddle onto the switch by inserting the air gap and side t abs and snapping s ecurely into place.
Once this step has been completed please return to section 3.
uncomfortable about performing this installation consult a qualified electrician.
6. Connect the green copper ground wire to the GROUND terminal.
7. Connect the black wire that goes to the light to the terminal marked LOAD.
8. Connect the black wire that comes from the electrical service panel (Hot)
to the terminal marked LINE.
9. Connect the white wire to the neutral terminal (use jumper wire if needed).
Note: The Traveler terminal is only used for 3-way or 4-way wiring and should
remain insulated if the switch installed in a 2-way system (one switch & one load).
10. Inser t Switch into the switch box being careful not to pinch or crush wire s.
11. Secure the Switch to the box using the supplied screws.
12. Mount the wall plate.
13. Reapply power to the circuit at fuse box or circuit breaker and test the system.
Basic Operation
The connected light can be turned ON/OFF in two ways,
1. Manually from the front panel o f the In-wall Switch
2. Remotely with a Z-Wave Controller
Manual Control
The Front Panel Rocker Switch allows the user to:
Turn ON/OFF the connected fixture.
To turn the connected fixture ON: Press and release the top of the rocker.
To turn the connected fixture OFF: Press and release the bottom of the rocker.
Linking your device
1. Follow the instructions for your Z-wave certified controller to include a device to
the Z-wave network.
2. Once the controller is ready to include your device, press and release the Program
Button to include it in the network.
Note: Your co ntroller may need to be within 10 feet of the device to be included.
3. Once your controller has confirm ed that the device has been included, refresh
the Z-wave network to optimize performance.Please reference the controller,
gateway’s manual for instructions.Now you have complete con trol to turn your
fixture ON/OFF according to groups, scenes, schedules and interactive auto mations
programmed by your controller.If your Z-wave certified controller features Remote
Access , you can now control your fixture from your mobile devi ces.
Note: To exclude and reset the devi ce, follow the instructions provided
by your Z-Wave controller.