Willis Electric ZW1102 User Manual

ZW1102 PIR Sensor
FCC/IC
Fede ra l Co mmunicati on s Co mmission (FCC ) St atement FCC Ca ut io n: Any changes o r mo di fications not ex pr essly approve d by t he p arty respon si bl e for comp li an ce could void t he u se r ’s aut ho ri ty to operate t hi s eq uipment. This d ev ic e complies wi th P ar t 15 of the FCC Rules . Op er ation is subj ec t to t he followin g tw o cond it io ns: (1) This device may n ot c au se harmful in te rf erence, and ( 2) t hi s device must acc ep t any inte rf er ence receiv ed , in cluding inter fe rence that may ca us e un desired ope ra ti on. NOTE : This equ ip ment has been tes te d an d found to comp ly w it h the limits fo r a Cl as s B digital devic e, purs ua nt t o Part 15 of the FCC Ru le s. The se l imits are des ig ne d to provide re as on able protec ti on agai ns t ha rmful inter fe re nce in a resident ia l installatio n. Thi s eq ui pment gener at es , uses and can radi at e ra dio frequen cy e ne rgy and, if not ins ta lled and used in ac co rd ance with the i ns tr uctions, may ca us h ar mful interfer en ce to radio commu ni ca tions.How ev er, t here is no guar an te e that inte rf er ence will not o cc ur i n a particular in st allation. If th is e qu ipment does c au se h armful inte rf er ence to rad io o r te levision re ce pt ion, which can be d et ermined by turn in g th e equipment o ff and o n, the us er i s en couraged to try t o co rrect the inter fe re nce by one or mor e of t he f ollowing me as ur es: Reor ie nt o r relocate th e re ce iving antenna .I ncrease the sep ar at ion between t he e qu ipment and rece iv er. Connect the e qu ip ment into an outl et o n a circuit different f ro m th at to which the rec ei ver is con ne ct ed.Consul t th e de aler or an experi en ced radio/TV te ch ni cian for help .T hi s equipment shou ld b e in stalled and o pe ra ted with minimu m di stance 20cm bet we en t he radiator a nd y ou r body.
IC Cau ti on : This d ev ic e complies wi th I nd ustry Canada li ce nce-exempt RS S st an dard(s). Op er at ion is subjec t to the f ol lo wing two cond it io ns: (1) this devi ce m ay n ot cause inte rf er ence, and (2) t hi s de vice must acce pt a ny i nterferen ce , in cluding inter fe rence that may ca us e un desired oper at io n of the device .
DECL AR ATION D E CO NF ORMITE D'IN DU ST RIE CANADA Ce pér ip hé rique a été tes té e t re connu conform e au x limites spéci fié es d ans RSS-210 . Son ut il is ation est sou mi se a ux deux conditi on s suivantes : (1) il n e do it p as provoque r d' in terférences g ên antes et (2) il d oi t to lérer les inter fé rences re.ues , no ta mment celle ss us ceptibles d 'e n pe rturber le fo nc ti onnement.
WARRANTY
Show H om e Pr oducts warr an ts t his product to be f re e fr om manufact ur in g defects for a peri od o f tw o years from the or ig inal date of cons um er purchase. This war ra nt y is limited to the r ep ai r or replacem en t of t his product onl y an d do es not extend t o co ns equential o r inci de nt al damage to ot he r pr oducts that may b e us ed w ith this prod uc t.
This w ar ra nty is in lieu of all o th er warranties , ex pr essed or impl ie d. S ome states do n ot allo w li mi tations on ho w lo ng a n implied war ra nt y lasts or permit t he e xc lusion or lim it at ion of inc id en tal or conseq ue nt ial damage, so th e ab ove limitatio ns m ay n ot apply to you .
This w ar ra nty gives you spe ci fic rights, and yo u ma y al so have other r ig ht s which vary fr om stat e to s ta te. if the unit sho ul d prove defecti ve w it hin the warra nt y pe riod.
WARNING
RISK O F FI RE
SPECIFICATIONS
Model:ZW1102 Power supply: battery CR123A , 3V. Signal (Frequency): 9 08.42 M Hz. Operating Range: Up to 50 M outdo or,up to 3 0M indo or Operating Tem p.: 0°C ~40°C Recommended install ation h eight : 2.4M Wireless Controller a nd the cl osest Z -Wav e receiver module. Specifications subje ct to cha nge wit hout no tice due to continuing produ ct impr oveme nt
Website www.ishowlight s.com
RISK O F EL EC TRICAL SHO CK RISK O F BU RN S CONT RO LL ING APPLIANCES : EXER CI SE E XTREME CAUTIO N WH EN USING Z-WAVE DEVI CE S TO CONTROL APP LIANCES. OP ER ATI ON OF THE Z-WAVE DEVI CE M AY BE IN A DIFF ER EN T ROOM THAN THE CONTRO LL ED AP PLIANCE, ALS O AN UNIN TE NT IONAL ACT IVATION MAY OC CU R IF T HE W RO NG BUTTON ON THE REMOTE I S PR ES SED. Z-WAVE DEVIC ES MAY AUTOM ATICALLY BE POWERED ON DUE TO TIM ED EVEN T PROGRA MM IN G. DEPENDIN G UP ON T HE AP PL I­ANCE , THESE UN ATTEN DE D OR U NINTENTIO NA L OP­ERATIONS COUL D PO SS IBLY RESU LT IN A HAZARDOUS COND IT IO N. FOR THE SE REASONS, W E RE CO MMEND DO NOT RETURN THIS PRO DU CT TO T HE S TORE THE FO LL OW ING: DO NOT USE Z-WAVE DE VI CE S TO CONTR OL ELECTRIC HEATERS OR ANY OTHER APPL IA NC ES WHICH MAY PR ES ­ENT A HAZARD OU S CO NDITION DUE TO U NATTE NDED OR UNIN TE NT IONAL OR AU TOMATIC POWER O N CO NT ROL.
Important safeguards
1.Do not attempt to disassembl e the PIR S ensor, u nless d escri bed in th e user’s manual. Th ere are n o user se rvice able pa rts.
2.Handle with Care – Avoid str iking o r shaki ng. Imp roper u se or sto rage could damage the PTR Se nsor. Mo difyi ng or tam perin g the device or its internal compo nents c an caus e a malfu nctio n and voi d the PIR Sensor’s warra nty.
3.If you feel the PIR Sensor or any pa rt of the C hoice Al ert sys tem is no t opera ting correctly or as described, p lease c ontac t
Instruction
The PIR Sensor is designe d to be use d indoo rs or out . When mo unted p roperly it can monitor large or ope n areas s uch as entrances, living roo ms, fam ily roo ms, dri veway s, back yards , walkways, workshops, e tc. Whe n the Sen sor det ects mo tion, i t will transmit a signal to the Cont rol Cen ter. The Zon e selec tion an d settings on the Control Ce nter de termi ne if an al arm or an alert sounds.
Preparing the PIR Senso r for I nst all ati on
1.The PIR Sensor consists of 2 par ts – The Sens or(Transm itter ) and the w all mount. Before installing, r emove t he the ba ttery of the S ensor. You’ll need to at tach th e batte ry lead s to CR12 3A 3V batt ery; Take care to note the polarit y marki ngs. Re place the battery cover and secure scr ew. batt ery in th e PIR Sen sor can l ast up to 9 m onths.
2.Use the ball-head mou nt to mou nt the Se nsor. The mi nimum s pacin g recommended is 5-6 ft, dep endin g on wher e you wan t to mount the PIR Sensor. Once the loca tion is s elect ed, bef ore mou nting y ou should perform a manual t est to co nfirm th e PIR Se nsor is within range of Cont rol Cen ter. Ref er to the Testi ng a Sens or section on pg 7. Mount the ba ll-he ad join t to the location with screws provi ded. On ce the ba ll-he ad join t is mounted to the wall, slide the bac k of the se nsor on to the ball-head joint. The moun ting an gle can b e adjus ted.
3.Erasing the Sensor from a Zone
If you n eed to remove the Sensor fro m a Zone, t he syst em will e rase th e entir e Zone, so any other Sensors will nee d to be put
back into that particular Zone .Step 1 - To eras e a Zone, p ress an d hold th e Learn button on the Control Cente r. Th e unit wi ll beep once.Step 2 - While holding t he Lear n butto n, pres s and hol d the Zone button to be erased. After fiv e secon ds the Co ntrol Center will sound two bee ps and th e Zone LE D indic ator wi ll flash t wice.Step 3 - Release all bu ttons . Th e Zone ha s been er ased. and delay time for next Trigger : 35 se c.
Note: T he Zone /PIR Se nsor ca nnot be e rased i f:
The Zone has been triggered f or an Aler t or alar m. The Sens or/Zo ne must b e reset. There is loss of signal f rom the S ensor t o the Control Center (such as low ba ttery, or Se nsor is o ut of ran ge).T he syst em is armed. The Control Cente r will so und thr ee beeps to indicate it could not era se the Zo ne.
Low Battery Indicator
The Control Center cont inuou sly mon itors a ll the Se nsors . If the Co ntrol Center does not receive a signal from any S ensor i t will be gin rap idly fla shing t he Zone LED indicator . This indicates one or more Sen sors in t he Zone m ay have l ow batt ery pow er and are unable to transmit a signal the necessa ry dist ance. I f all bat terie s and/o r Sensors are installed at the same time into a Zone, it is reco mmend ed to rep lace th e batte ries in a ll Sensors in the Zone. However, you can che ck the PI R Senso r statu s indep enden tly by placing the Control Center in Test mode (see Testi ng a Sens or on pag e 7) and tr igger t he Sens or separately. If mounted, wave hand in front of Se nsor, or p ress ac tivat ion but ton for t wo seconds inside battery compartment. If the Se nsor do es not tr igger a n alert t hen rep lace the battery with a new one.
Note: T he Sens or dete ction s ystem i s ‘rang e dependant’, which mean s Senso rs loca ted
closer to the Control Cen ter may s eem to ha ve batt eries t hat las t longe r than those Sensors at a greater distance. Als o, keep i n mind, b ecaus e the Mot ion Sen sor is continually checking for activity the battery life is l ess tha n the lit hium ce ll batt eries i n the other Sensors.
Package content
PIR Sensor - 1pcs Magnet bracket - 1pcs Battery CR123A - 1pcs Screw - 2pcs
Detection pattern:
100degree 5 x5 M at 25°C Top view
Side View
.
Loading...