Williams Sound WIR SYS 1 User Manual

SoundPlus
®
Basic Courtroom System • Model WIR SYS 1
SoundPlus®Basic Courtroom System • Model WIR SYS 1
D
D
NOTE: SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE!
Description:
The Basic Courtroom System, model WIR SYS 1, is the complete hearing assistance solution for the courtroom. Listeners wear wireless RX22-4 receivers to hear the proceeding anywhere in a 28,000 ft
2
area**. For the severely hard of hearing, the RX22-4 can be equipped with a neckloop (included) to amplify their telecoil equipped hear­ing aid. SoundPlus infrared technology ensures privacy and security: the message of the proceeding doesn’t travel outside the walls of the courtroom.
Each WIR SYS 1 package includes: one (1) TX9 emitter, one (1) MOD 232 modulator, four (4) body-pack style RX22-4 receivers, four (4) HED 021 Headphones, one (1) neckloop and one (1) RPK 005 rack panel kit. The WIR SYS 1 meets and exceeds government ADA regulations for public hearing assistance, and is backed by a five-year warranty.*
Size, Weight: 8.5" W x 8.2" D x 1.7" H (21.5 cm x 20.8 cm x 4.4 cm), 3.1 lbs (1.5 kg) Color: Black epoxy paint with white legends Rack Mount: 1/2 rack space wide, 1 rack space high, one or two modulators may be mounted in a
single IEC rack space with RPK 005 (single) or RPK 006 (double) Rack Mount Kits
Power Supply: Wall Transformer, 24VAC, 50-60 Hz, 15VA
North America: TFP 016, UL/CSA Europe: TFP 027-01, 2-pin Schuko plug, CE
UK: TFP 027-02, 3-pin UK plug, CE Modulation: FM Wideband, +50kHz deviation, 50uS pre-emphasis Carrier Frequency: Channel A: Selectable, 2.3/2.8/3.3/3.8 MHz,
Channel B: Selectable, 2.3/2.8/3.3/3.8 MHz Signal-to-Noise Ratio: More than 60dB Frequency Response: 30 to 16,000 Hz, +1 dB, -3 dB, electrical response Total Harmonic Distortion: Less than 2%, electrical response Audio Processing: Compression (slope) adjustable from 1:1 to 4:1
Switchable compression gain: Moderate: 16 dB. Max: 33 dB Auto Carrier Shut-Off: 15-minute timer shuts off carrier when no audio is present (can be disabled)
MOD 232 Modulator:
Two Channel Infrared System Modulator
Williams Sound
Power
Phones
+9 +6 +3 0
-3
-6
-9
-12
-15
-18
+9 +6 +3 0
-3
-6
-9
-12
-15
-18
3.8
3.3
2.8
2.3
Level
5
0
1
2
3
46
7
8
9
10
Level
5
0
1
2
3
46
7
8
9
10
Compress
3.8
3.3
2.8
2.3
Compress
Inputs Mixed
Stereo
IR
CH A
CH B
Frequency
(MHz)
Frequency
(MHz)
Channel A Channel B
Microprocessor Controlled
Frequency Synthesized
Fig. 1: MOD 232 Front Panel
Power Switch: Two-position push button, ON/OFF Power Indicator: Green LED Audio Level Controls: CHA and CHB Input Level, rotary knobs Audio Indicators: CHA and CHB Audio Level, 10-segment LED’s Carrier LEDs: 4 green LED carrier “on” indicators per channel (indicates frequency, malfunctions) Compress Control: 1:1 to 4:1 Input Mix LED: Indicates inputs A and B audio are mixed and transmitted by CHA, CHB off Stereo LED: Indicates stereo mode Phones Switch: Selects CH1 or CH2 for phones when not in stereo mode Phones Output: 1/4" TRS headphone jack. Accepts stereo, mono, and any impedance phones. Infrared Test LED: IR LED for receiver testing, monitoring, and audio signal testing.
ADA COURTROOM ASSISTIVE LISTENING SYSTEM
©2006, Williams Sound Corp. MCAT 027D
1
**In single channel mode with TX9 emitter * 90 days on accessories.
SoundPlus
®
Basic Courtroom System • Model WIR SYS 1
SoundPlus®Basic Courtroom System • Model WIR SYS 1
D
D
NOTE: SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE!
Dimensions, Weight: 11.25" W x 6.25" H x 2.125" D (28.6 cm x 15.9 cm x 5.4 cm), 1.9 lbs (0.9 kg) Color: Black with white legends, red acrylic lens Power Supply: Wall Transformer, 24 VAC, 50-60 Hz, 35 VA, 3-pin MOLEX Connector
North America: TFP 010, UL/CSA
Europe: TFP 027-01, 2-pin Schuko plug, CE
UK: TFP 027-02, 3-pin UK plug, CE
Note: Each WIR TX9 requires its own power supply Power Cable: NEC Class 2 wiring, two-conductor, 18 ga, 200’ (61 m) max. length Indicators: Green LED power indicator, red LED baseband indicator Carrier Frequency: 50 kHz to 8 MHz Emitter IR Power: 3.5 watts Coverage Area: 28,000 ft2(2,600 m2) in single-channel mode when using the RX12-4 or RX22-4 Receiver
18,000 ft2(1,700 m2) in two-channel mode when using the RX12-4 or RX22-4 Receiver
3,500 ft2(325 m2) in single-channel mode when using the RX14-2 Receiver
3,063 ft2(285 m2) in single-channel mode when using the RX16 Receiver
(See coverage area diagrams) Baseband Input: BNC, 100 mV per carrier, 50 Ω, for use with WIR TX9 or MOD 232 only Baseband Output: BNC, 50 Ω, for use with TX9 only Baseband Cable: RG 58 Coax, BNC connectors, maximum 1000' (300 m) length Operating Requirements: 0-50º C ambient temperature, non-condensing, non-corrosive atmosphere Mounting Kits: Wall or Ceiling Mount: BKT 024 Omnidirectional mount, Mic Stand Kit: SS-11 or SS-6 Warranty: 5 years on Emitter, 90 days on accessories Approvals: CE, FCC, RoHS, WEEE Compatible Receivers: WIR RX22-4 Four-Channel Receivers, RX14-2 Two-Channel Receiver,
RX16 Two-Channel Receiver
Configuration
Switches
Input CH A Input CH B
Audio Line
Output
CH A
CH A
CH B
CH B
50 Ohms
100 Ohms
Made in USA
24V
24 VAC, 15 VA, 50-60 Hz
Power In
Baseband
Input Output Output
MOD 232 Infrared System Modulator
Plug
Williams Sound
12345678
12345678
Fig. 2: MOD 232 Rear Panel
Power Input: 3-Pin Molex, 24 VAC, 50-60 Hz, 15 VA Audio Input Jack: CHA and CHB combination XLR/TRS jack Mic Level: Balanced, Lo-Z, 100 µV min. to 90 mV max., 1mV nominal, 3 kΩ input impedance, sup-
plies switchable simplex power per DIN 45596 for condenser mics Line Level: Balanced or unbalanced, 21 mV min. to 10 V max., 212 mV nominal, 100 kΩ Audio Line Output Jacks: RCA Jack, CHA and CHB, 500 mV, unbalanced, 100 Ω source impedance, load imped-
ance must be greater than 1kΩ Configuration Switches: CHA and CHB 8-position DIP switch, selects Mic/Line input, compressor gain, simplex
power, discrete or mixed inputs, carrier frequency, channel disable, auto shut-off timer Baseband Input Jack: BNC, allows mixing with additional MOD 232 Modulator (4CH operation), 100mV, 50Ω
input impedance, use with MOD 232, BNC, RG-58 Cable Baseband Output Jack: Two BNC jacks carry baseband signal, 100 mV/channel, 50 Ω source impedance, for use
with WIR TX9 or MOD 232 only Approvals: CE, FCC, RoHS, WEEE Operating Requirements: 0-50º C ambient temperature, non-condensing, non-corrosive atmosphere Warranty: 5 years on modulator, 90 days on accessories
WIR TX9 Emitter:
©2006, Williams Sound Corp. MCAT 027D
2
SoundPlus
®
Basic Courtroom System • Model WIR SYS 1
SoundPlus®Basic Courtroom System • Model WIR SYS 1
D
D
NOTE: SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE!
Fig. 3: WIR TX9 Rear Panel
Fig. 4: Receiver Coverage Area with TX9 Emitter in Single Channel Mode
The coverage area for the TX9 will vary depending on the receiver being used. The diagram above demonstrates the receiver coverage when operating a single TX9 emitter in single channel mode. Patterns are direct radiation patterns.
Note: Reflections of the infrared light from walls, ceilings and floors may change these patterns.
RX22-4
RX14-2
RX16
©2006, Williams Sound Corp. MCAT 027D
3
90
Feet
80
70
60
50
40
30
20
10
0
-10
-20
-30
-40
-50
-60
-70
-80
-90 0
Feet
10
20
30
Multi-Channel Infrared Transmitter
WARNING: TO REDUCE THE RISK OF FIRE OR
Class 1
ELECTRIC SHOCK DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE.
LED Product
Note: It is normal for this unit to feel warm while it is in operation.
Power Supply Wiring:
Use NEC, Class 2 Wiring, 18 ga. minimum, 200 ft. (70m) maximum length (18 ga.)
Baseband Signal Wiring:
Use RG58 Coax,1000 ft. (350m) max. length
Williams Sound Corp., Minneapolis, Minnesota, USA Patent Pending
24 VACNC
Power In:
24VAC
~
50-60Hz
35VA
50
40
RoHS
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
Made in U.S.A.
Plug
Power On Baseband On
90 100 110 120 130 140 150 160
80
70
60
Mounting
Bracket
www.williamssound.com
Baseband Signal Wiring:
Use 50 Ohm Coaxial Cable (RG58)
Baseband (Modulation)
InOut Out
50 Ohms
Receiver Coverage Area with TX9 Transmitter in Single Channel Mode
RX22-4 Receiver
RX14-2 Receiver
RX16 Receiver
Loading...
+ 7 hidden pages