Floor
Very quietly heat large
areas with this easily-
installed, space and
energy-saving furnace!
Williams’ floor furnaces use no abovethe-floor room space as it unobtrusively
and efficiently circulates warm air . . . and
does it without the aid of a blower.
Our models are fitted with an automatic
floor-register grille temperature control
and nonelectric pilot to ensure
continuous heat – even during power
outages.
Floor Furnace
Furnace
Floor furnaces are designed to give you
maximum efficiency, low-fuel
consumption and quiet operation.
These models offer affordable
solutions for limited-space floor
plans, remodels, remote cabin
locations and new construction.
45,000 and 60,000
Design Features
No electricity required
“Matchless” pilot igniter
Easy installation
Combustion chamber lifts out for easy servicing
Long-life and quiet heavy-duty burner
Wall-mounted thermostat included
Natural and propane gas models
(Conversion kit available)
Automatic temperature and safety controls
Resettable vent-limit safety switch
Floor Furnace
Model Number
PropaneNatural
4505622
6005622
4505621
6005621
Easy Installation
NOTE: If two joists
are cut, use a
double header
Headers
Btu/hr
Input
Btu/hr
Output
Efficiency Percentages
Thermal AFUE Length Height Width Length
45,000 31,500 70.0 57.0 32" 28½" 24¼" 32⅜" 147
60,000 42,000 70.0 58.0 42" 28½" 24¼" 42⅜" 174
Width
24"
24"
Dimensions
Floor Opening
Shipping
Weight (lbs.)
All units have ½" gas connection.
Features
Floor Register Temperature Control
Williams' floor furnaces are equipped with automatic floor
register grille temperature control. This meets the latest
American National Standards Institute Requirements. In
extreme weather conditions, this control can be overridden to
allow increased heat output.
Floor
Joist
This space must be the same
size as the opening cut in the
floor
NOTE: The headers must not
be a smaller size lumber than
the joists
Temperature Control
A self-generating millivolt electrical system powers a wallmounted heating thermostat. This provides maximum room
comfort while allowing economical automatic operation.
Furnace
JOIST HEADERS
DEPTH OF
FURNACE
18" MINIMUM ON
CONTROL END OF FURNACE
VENTILATION
OPENING
FIRST FLOOR
4" VENT PIPE
(¼" RISE PER FOOT)
GROUND LEVEL
DRAIN FROM
FURNACE PIT
12"
12" MINIMUM
12" MINIMUM ON ALL SIDES
EXCEPT CONTROL END OF FURNACE
All units have 4" flue pipe diameter and 18" floor-to-center of flue connection.
Recommended Minimum Clearances
12" between the floor furnace and doors, draperies or other combustible materials
6" between the floor furnace and adjacent walls
15" walk space along two sides of the furnace
250 West Laurel Street · Colton, California 92324 USA
(909) 825-0993 · Fax: (909) 370-0581 or (909) 824-8009
Consumer Line: (888) 256-6465
Homeowner Assistance: (909) 426-0978
www.e-wfc.com
Accessories
High-Altitude Units
Conversion Kits
Requires
No Electricity
Great During
Power Outages
18" MINIMUM
WORK SPACE
Important
· Read owner's manual before using/installing.
· Photographs are representative only.
· Specify propane or natural gas when ordering.
· Check local codes and ordinances for permitted uses.
· Consult installation manual for clearances prior to installation.
· We reserve the right to amend product specifications without notice.
· Installation and servicing recommended by a qualified service person.
· Please read the warranty, for any limitations or disclaimers. Combustion
chamber carries a ten-year limited warranty. All other parts carry a one-year
li.llimited warranty.
· Venting must comply with the "Venting and Chimney Requirements" section of the
...installation manual.
· Replacement floor furnaces of the same or lesser Btu/hr input rating may
be installed in the same location as the replaced furnace when
replacement does not create an unsafe condition.
© 2008 Williams Furnace Co. Printed in U.S.A. All Rights Reserved Subject to Change without Notice L1026 5/08