Willhi WH7016C User Manual

WH7016C
Thermostat Product
Manual
 Installation opening size:
 Wiring diagram
Option
Power
321
switch
5 6874
NT C
12V
Load
12V
Terminals 1 and 2: Normally opened contact of relay Terminals 3 and 4: Connect the power 12V Terminals 5 and 6: The factory parameter settings of thermostat can be
locked after a short circuit, the user can not modify.
Terminals 7 and 8: Temperature connection sensor
Note: The load refers to the heating or cooling equipment on control.
 Electrical performance: Temperature measurement range: -50  ~ 110  Temperature control range: -50  ~ 110  Temperature measurement error: ± 0.5  Sensor Type: NTC (10K/3435) Control accuracy: 1  Working voltage: AC/DC12V Working current: <2W Relay contact point current: AC 7A/220V Data storage : Yes Working temperature: 0  ~ 50  Storage temperature: -10  ~ 60 