Wilkerson R16 User Manual

Richland, MI 49083 Tel: (269) 629-5000
Installation & Service Instructions 83-059-000
Regulator Model R16 With Variations and Accessories
ISSUED: April, 2006 Supersedes: September, 1995
Doc.# 83059000, ECN# 060135, Rev. 1
WARNING
!
To avoid unpredictable system behavior that can cause personal injury and property damage:
• Disconnect electrical supply (when necessary) before installation, servicing, or conversion.
• Disconnect air supply and depressurize all air lines connected to this product before installation, servicing, or conversion.
• Operate within the manufacturer’s specified pressure, temperature, and other conditions listed in these instructions.
• Medium must be moisture-free if ambient temperature is below freezing.
• Service according to procedures listed in these instructions.
• Installation, service, and conversion of these products must be performed by knowledgeable personnel who understand how pneumatic products are to be applied.
• After installation, servicing, or conversion, air and electrical supplies (when necessary) should be connected and the product tested for proper function and leakage. If audible leakage is present, or the product does not operate properly, do not put into use.
• Warnings and specifications on the product should not be covered by paint, etc. If masking is not possible, contact your local representative for replacement labels.
INSTALLATION
1. Install as close as possible to where regulated air is needed.
2. Install the unit with the air flowing in the direction indicated by the arrow.
3. Install the same pipe size unit as the pipe line in use. Avoid using fittings, couplings etc., that restrict airflow, unless maximum flow is not needed.
4. Regulator may be installed with the adjusting knob in any position. Attach gauge to one 1/4" female gauge port and plug the other 1/4" female port or use it as a regulated outlet port.
5. Turning the adjusting screw clockwise increases the regulated pressure and turning it counterclockwise decreases the regulated pressure.
6. Panel mount regulators require a 15/16" diameter hole and are mountable on panels from 1/8" to 1/2" thick.
7. Maximum inlet pressure and operating temperature ratings are 300 psig (21 bar) and 175°F (79°C).
MAINTENANCE
1. The regulator can be disassembled for servicing without removal from line.
2. Occasionally remove bottom plug and clean plug, body and valve seat (vent air line on both sides of regulator).
3. TO DISASSEMBLE - shut off air to regulator and vent air line on both sides of regulator. Turn adjusting knob counterclockwise to relieve compression on spring. Remove screw, lock knob, adjusting knob (panel mount nut, if used), tamper-resistant kit (on tamper-resistant models) and cover cap. Remove the four screws, cover and regulating spring. Diaphragm assembly can now be removed. By removing bottom plug and spring the valve stem can be removed from the bottom of the regulator.
4. IF UNIT WILL NOT REGULATE TO PRESSURE NEEDED OR IF PRESSURE BECOMES EXCESSIVE-remove bottom plug, spring, and valve assembly. Clean and check o-ring, valve stem and valve seat for water damaged parts. Install Repair Kit No. RRP-95-130 for self-relieving models and Repair Kit RRP-95-129 for non-relieving models for complete overhaul.
5. IF UNIT LEAKS AT RELIEF PORT, install proper repair kit as listed under Repair Kits and Replacement Parts.
6. WHEN REPLACING DIAPHRAGM ASSEMBLY - Diaphragm assembly RRP-96-213 includes disk seal (not shown) installed. Seal not required on nonrelieving models.
7. TO REPLACE O-RING-This o-ring is above a metal washer which cannot be removed. Using a pointed probe of some kind, pull o-ring out. Force new o-ring through washer hole into o-ring cavity.
REPAIR KITS AND REPLACEMENT PARTS
SELF-RELIEVING REPAIR KIT
(includes self-relieving diaphragm assembly,
valve assembly and o-rings) ........................................... RRP-95-130
NON-RELIEVING REPAIR KIT
(includes nonrelieving diaphragm assembly,
valve assembly and o-rings) ........................................... RRP-95-129
Self-Relieving Diaphragm Kit ............................................ RRP-96-213
Non-Relieving Diaphragm Kit ........................................... RRP-96-216
Valve Assembly (valve stem, valve spring) ...................... RRP-96-215
Regulating Springs:
0-50 psi ............................................................................ RRP-95-222
0-125 psi .......................................................................... GRP-95-224
0-250 psi .......................................................................... RRP-95-218
Adjusting Knob Assembly ................................................. RRP-95-023
ACCESSORIES
Gauges:
0-60 psig ....................................................................... K4520N14060
0-160 psig ..................................................................... K4520N14160
0-300 psig ..................................................................... K4520N14300
Panel Mount Nut ................................................................ GPA-95-032
Wall Mounting Bracket ...................................................... GPA-95-012
Wall Mounting with Panel Nut ........................................... GPA-95-011
Wall Mounting Bracket (Combo’s) .................................... RRP-95-090
Tamper Resistant Kit ......................................................... RRP-95-006
! WARNING
Product rupture can cause serious injury.
Do not connect regulator to bottled gas.
Do not exceed maximum primary pressure rating.
WARNING
!
FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE.
This document and other information from The Company, its subsidiaries and authorized distributors provide product and/or system options for further investigation by users having technical expertise. It is important that you analyze all aspects of your application, including consequences of any failure and review the information concerning the product or systems in the current product catalog. Due to the variety of operating conditions and applications for these products or systems, the user, through its own analysis and testing, is solely responsible for making the final selection of the products and systems and assuring that all performance, safety and warning requirements of the application are met.
The products described herein, including without limitation, product features, specifications, designs, availability and pricing, are subject to change by The Company and its subsidiaries at any time without notice.
EXTRA COPIES OF THESE INSTRUCTIONS ARE AVAILABLE FOR INCLUSION IN EQUIPMENT / MAINTENANCE MANUALS THAT UTILIZE THESE PRODUCTS. CONTACT YOUR LOCAL REPRESENTATIVE.
LOCK
KNOB
PANEL
MOUNT
NUT
BONNET
NNR
83-059-000
SCREW
ADJUSTING KNOB
TAMPER­RESISTANT KIT (Optional)
SCREW (4 Required) NNR
REGULATING
SPRING
BODY
NNR
CAP
NNR
O-RING
ADJUSTING SCREW ASSEMBLY
DIAPHRAGM ASSEMBLY
PIPE PORT PLUG NNR
VALVE ASSEMBLY
NNR=NOT NORMALLY REPLACED
VALVE
SPRING
O-RING
BOTTOM PLUG NNR