Wilkerson M28 User Manual [en, es, fr]

!
!
!
Pneumatic Division
!
Richland, Michigan 49083 269-629-5000
Installation & Service Instructions 84-010-000
Coalescing Filter Models M18 and M28
ISSUED: September, 2007 Supersedes: September, 2006
Doc. #84010000, EN# 070757, Rev. 5
WARNING
To avoid unpredictable system behavior that can cause personal injury and property damage:
Disconnect electrical supply (when necessary) before installation,
servicing, or conversion.
Disconnect air supply and depressurize all air lines connected to this
• product before installation, servicing, or conversion.
Operate within the manufacturer’s specified pressure, temperature,
• and other conditions listed in these instructions.
Medium must be moisture-free if ambient temperature is below
• freezing.
Service according to procedures listed in these instructions.
• Installation, service, and conversion of these products must be performed by knowledgeable personnel who understand how pneumatic products are to be applied.
After installation, servicing, or conversion, air and electrical supplies
(when necessary) should be connected and the product tested for proper function and leakage. If audible leakage is present, or the product does not operate properly, do not put into use.
Warnings and specifications on the product should not be covered by
• paint, etc. If masking is not possible, contact your local representative for replacement labels.
CAUTION
Polycarbonate bowls and sight domes, being transparent and tough, are ideal for use with Filters and Lubricators. They are suitable for use in normal industrial environments, but should not be located in areas where they could be subjected to direct sunlight, an impact blow, nor temperatures outside of the rated range. As with most plastics, some chemicals can cause damage. Polycarbonate bowls and sight domes should not be exposed to chlorinated hydro-carbons, ketones, esters and certain alcohols. They should not be used in air systems where compressors are lubricated with fire-resistant fluids such as phosphate ester and di-ester types.
Metal bowls are recommended where ambient and/or media conditions are not compatible with polycarbonate bowls. Metal bowls resist the action of most such solvents, but should not be used where strong acids or bases are present or in salt laden atmospheres. Consult the factory for specific recommendations where these conditions exist.
TO CLEAN POLYCARBONATE BOWLS USE MILD SOAP AND WATER ONLY! DO NOT use cleansing agents such as acetone, benzene, carbon
tetrachloride, gasoline, toluene, etc., which are damaging to this plastic.
Bowl guards are recommended for added protection of polycarbonate bowls where chemical attack may occasionally occur.
3. Unit must be installed with the flow in the direction of the flow arrow on the body cover and with bowl down.
void using reducing bushings, couplings, etc., whenever possible
4. A to install this product. These devices restrict air flow and can affect performance.
5. Do
not install this product in any application where the pressure drop across the unit will exceed 7 psig (0.5 bar). This will cause the Differential Pressure Indicator to shift to RED indicating element replacement is required.
6. Maximum pressure rating is 150 psig (10.3 bar) for plastic bowl/bowl guard assembly, and 250 psig (17.2 bar) for metal bowl with sight gauge. Temperature range is 32°F to 125°F (0°C to 52°C) for plastic bowl/bowl guard assembly, and 32°F to 150°F (0°C to 65.5°C) for metal bowl with sight gauge.
o install a drain line, use the following procedure:
7. T
a. On units with the MANUAL DRAIN, attach flexible tubing having an
I.D. of 3/16” (4.8 mm) to drain stem.
b. On units with AUTOMATIC FLOAT DRAIN, install using a 3/8
or 10mm ID instant tube fitting or 3/8" ID fle
xibile tubing.
NOTE: CONTAMINATES REMOVED FROM THE COMPRESSED AIR SYSTEM MUST BE DISPOSED OF IN ACCORDANCE WITH LOCAL, STATE AND FEDERAL STANDARDS.
MAINTENANCE THIS UNIT MAY BE SERVICED WITHOUT REMOVING THE
UNIT FROM THE COMPRESSED AIR LINE.
1. Filter element replacement:
a. Differential Pressure Indicator is RED indicating that the filter element
requires ser
b. Depressurize unit. c. Remove bowl/bowl guard assembly by pushing up on bowl assembly
and turning counter clockwise. Clean inside of bowl using a clean cloth.
d. Remove filter element by turning element clockwise. e. Install a new filter element / O-ring seal and reassemble unit in reverse
order.
vicing.
Inspect plastic bowl for damage and replace if necessary.
WARNING
WARNING
To avoid polycarbonate bowl rupture that can cause personal injury or property damage, do not exceed bowl pressure or temperature ratings. Polycarbonate bowls have a 150 PSIG pressure rating and a maximum temperature rating of 125°F.
Safety Guide
For more complete information on recommended application guidelines, see the Safety Guide section of Pneumatic Division catalogs or you can download the Pneumatic Division Safety Guide at: www.wilkersoncorp.com
INSTALLATION
1. Refer to WARNINGS and CAUTIONS prior to installation.
2. Install as close to the point of use as possible.
FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE.
This document and other information from The Company, its subsidiaries and authorized distributors provide product and/or system options for further investigation by users having technical expertise. It is important that you analyze all aspects of your application, including consequences of any failure and review the information concerning the product or systems in the current product catalog. Due to the variety of operating conditions and applications for these products or systems, the user, through its own analysis and testing, is solely responsible for making the final selection of the products and systems and assuring that all performance, safety and warning requirements of the application are met.
The products described herein, including without limitation, product features, specifications, designs, availability and pricing, are subject to change by The Company and its subsidiaries at any time without notice.
EXTRA COPIES OF THESE INSTRUCTIONS ARE AVAILABLE FOR INCLUSION IN EQUIPMENT / MAINTENANCE MANUALS THAT UTILIZE THESE PRODUCTS. CONTACT YOUR LOCAL REPRESENTATIVE.
NOTE: DO NOT TOUCH THE EXTERIOR FOAM COVER OF THE ELEMENT. USE THE PLASTIC BAG THE ELEMENT IS SHIPPED IN TO HOLD THE ELEMENT AND INSTALL INTO THE BODY.
2. Liquid level in the bowl must be kept below the level indicator line as marked. It is recommended practice to drain a unit equipped with the manual drain at least once during an eight (8) hour period. To do so,
rotate the drain knob to the left one or two turns.*
3. Before returning unit to service, insure that all seals have been reinstalled or replaced and bowl is locked into position with drain properly secured.
4. If the Differential Pressure Indicator no longer functions, it must be replaced.
*NOTE: In the event that the drain knob is over-rotated it may become disengaged from the drain stem. In such a case, pull down on both the knob and the stem while rotating to the right to re-engage.
DRAINS
Manual Drain ....................................................................... GRP-96-685
Automatic Mechanical Drain (Nitrile) ................................... GRP-95-973
Automatic Mechanical Drain (Fluorocarbon) ....................... GRP-95-981
ACCESSORIES
Joiner set ..............................................................................GPA-96-601
T-Bracket ...............................................................................GPA-96-602
T-Bracket with Joiner set .......................................................GPA-96-603
C-Bracket (18 Series) ...........................................................GPA-96-604
C-Bracket (28 Series) ...........................................................GPA-96-605
Differential Pressure Indicator
Nitrile ................................................................................DP8-01-000
Fluorocarbon ....................................................................DP8-02-000
!
!
!
!
Pneumatic Division
Richland, Michigan 49083 269-629-5000
AVERTISSEMENT
Afin d’éviter un fonctionnement imprévu du système pouvant occasion­ner des blessures aux personnes et des dommages matériels :
Débrancher l’alimentation électrique (si nécessaire) avant toute ins-
tallation, entretien ou conversion.
• Débrancher l’alimentation en air et dépressuriser toutes les canalisa­tions d’air connectées à cet appareil avant installation, entretien ou conversion.
Utiliser l’appareil conformément aux normes de pression, tempé-
rature, et autres conditions spécifiées par le fabricant dans ces instructions.
Le médium doit être exempt d’humidité si la température descend en
dessous de 0°C.
• L’entretien doit se faire conformément aux procédures décrites ici.
• L’installation, l’entretien, et la conversion de ces appareils doivent être effectués par des personnels qualifiés, au fait des techniques pneumatiques.
• Après installation, entretien, ou conversion, les alimentations en air et en électricité (si nécessaire) seront connectées et l’appareil testé pour vérifier son fonctionnement correct et l’absence de fuites. Si l’appareil présente une fuite audible ou ne fonctionne pas correcte­ment, ne pas l’utiliser.
Les inscriptions concernant les avertissements et spécifications
sur l’appareil ne devront pas être recouvertes de peinture, etc. Si le masquage est impossible, contactez votre représentant local pour des étiquettes de remplacement.
ATTENTION
Les bols en polycarbonates et apercevoir des dômes, étant durs et trans­parents, sont idéaux pour l’utilisation dans les filtres et lubrificateurs. Ils conviennent aux environnements industriels normaux, mais ne devront pas être placés dans des endroits où ils pourraient être soumis à une exposition à la lumière directe du soleil, aux chocs, ou aux températures en-dehors de la plage normale d’utilisation. Ce plastique est, comme tout autre, susceptible d’être endommagé par l’action de certains produits chimiques. Les bols en polycarbonate et apercevoir des dômes ne doivent pas être exposés aux hydrocarbures chlorés, cétones, éthers, et certains alcools. Ils ne doivent pas être utilisés dans des systèmes pneumatiques dont les compresseurs sont lubrifiés par des fluides résistant au feu, tels que les esters et diesters de phosphate.
Les bols métalliques sont recommandés quand les conditions ambiantes et/ou celles du médium sont incompatibles avec les bols en polycarbonates. Les bols métalliques sont résistants à la plupart de ces solvants mais ne doivent pas être utilisés en milieu fortement acide ou basique, ou dans une atmosphère salée. Si de telles conditions existent, contactez le fabricant pour des recommandations spécifiques.
NETTOYEZ LES BOLS EN POLYCARBONATE UNIQUEMENT A L’EAU ET AU SAVON DOUX ! NE PAS utiliser d’agents nettoyants tels que l’acétone,
le benzène, le tétrachlorure de carbone, l’essence, le toluène, etc., qui en­dommageraient ce plastique.
De plus, il est recommandé d’équiper les bols en polycarbonates de carters de protection, là où une agression chimique est possible.
Pour éviter le rupture de bol de polycarbonate qui peut causer la blessure personnels ou les dommages de propriété, ne pas dépasser la pression de bol ou les classements de température. Les bols de Polycarbonate ont une 150 pression de PSIG évaluant et une température maximum évaluant de 125°F.
Pour obtenir de plus amples informations sur les directives à appliquer recommandées, prière de vous reporter à la section Guide de sécurité des catalogues de la Pneumatic Division ou de télécharger le Guide de sécurité de la Pneumatic Division sur le site:
INSTALLATION
1. Lire l’avertissement ci-haut avant l’installation.
2. Installer le dispositif aussi près du point d’utilisation que possible.
AVERTISSEMENT
Guide de sécurité
www.wilkersoncorp.com
Instructions d'installation et Service 84-010-000 (French)
Le Filtre fusionnant Modèle M18,
M28
DISTRIBUE: Septembre, 2007 Supplantent: Septembre, 2006
Doc.# 84010000, EN# 070757, Rev. 5
3. Ce dispositif doit être monté de manière à ce que le débit soit orienté dans la direction de la flèche placée sur l’enveloppe du corps, le bol étant vers le bas.
4.
Éviter dans toute la mesure du possible d’utiliser des bagues,
raccords ou autres dispositifs de réduction pour installer ce produit. Ils diminuent le débit d’air et risquent d’affecter le fonctionnement.
pas installer ce dispositif sur les systèmes où la différence de
5. Ne pression entre l’entrée et la sortie du dispositif est appelée à dépasser
0.55 bar (8 psig). Dans ce cas, l’indicateur de pression différentielle devient ROUGE, ce qui indique qu’il faut remplacer l’élément filtrant.
6. La pression maximale d’utilisation est de 10.3 bar (150 psig) pour bol/protège-bol en plastique, et 17.2 bar (250 psig) pour bol en métal avec jauge visuelle. La température d’utilisation se situe entre 0°C et 52°C (de 32°F à 125°F) pour bol/protège-bol en plastique, et 0°C et
65.5°C (de 32°F à 150°F) pour bol en métal avec jauge visuelle.
7. P
our mettre en place une conduite de vidange, procéder comme suit:
les modèles à VIDANGE MANUELLE, raccorder un tuyau
a. Sur fle
xible de 4.8 mm (3/16”) de diamètre intérieur au raccord de
vidange.
b. Sur les modèles à VIDANGE AUTOMATIQUE À FLOTTEUR,
installer ou 3/8”
utilisant un 3/8 ou 10 mm ID installation de tube immédiate
tuyaux de flexibile d’ID.
NOTE : LES CONTAMINANTS ÔTÉS DU SYSTÈME À AIR COMPRI­MÉ DOIVENT ÊTRE MIS AU REBUT CONFORMÉMENT AUX RÈGLE­MENTS LOCAUX, PROVINCIAUX ET FÉDÉRAUX.
ENTRETIEN L’ENTRETIEN DE CE DISPOSITIF PEUT S’EFFECTUER
SANS LE DÉMONTER DE LA CONDUITE D’AIR COMPRIMÉ.
1. Remplacement de l’élément filtrant:
a. Remplacer l’élément quand l’indicateur de pression différentielle
est ROUGE.
b. Mettre le dispositif hors pression. c. Ôter l’ensemble de bol/protège-bol en poussant l’ensemble vers le
haut et en le tournant dans le sens horaire. Nettoyer l’intérieur du
avec un chiffon sec et propre. Examiner le bol pour s’assurer
bol qu’il n’est pas endommagé et le remplacer si nécessaire.
AVERTISSEMENT
LA DEFAILLANCE, LE CHOIX ERRONE OU L’USAGE NON CONFORME DES PRODUITS ET/OU SYSTEMES ICI DECRITS, OU PRODUITS Y AFFERANT, PEUVENT ENTRAINER LA MORT, DES BLESSURES AUX PERSONNES ET DES DOMMAGES MATERIELS.
Ce document et autres informations de « The Company », ses filiales et distributeurs autorisés offre des options complémentaires d’utilisation du produit et/ou système pour des utilisateurs ayant l’expertise technique requise. Il est important que vous analysiez tous les aspects de l’usage prévu, y compris les conséquences de toute défaillance, et que vous passiez en revue les informations concernant les produits et systèmes dans le catalogue actuel des produits. En raison de la diversité des conditions de fonctionnement et d’utilisation de ces produits ou systèmes, l’utilisateur, et lui seul, selon ses propres analyses et tests, porte la responsabilité du choix final des produits et systèmes. Il est aussi de sa responsabilité pleine et entière de s’assurer que les produits soient utilisés conformément aux normes de sécurité et avertissements d’usage.
Les produits décrits ici, y compris, mais non exclusivement, les caractéristiques des produits, spécifications, aspects, disponibilité et prix, sont susceptibles de modification à tout moment et sans préavis par « The Company » et ses filiales.
DES EXEMPLAIRES SUPPLEMENTAIRES DE CES INSTRUCTIONS SONT DISPONIBLES POUR ACCOMPAGNER LES APPAREILS/MANUELS D’ ENTRETIEN CORRESPONDANT A CES PRODUITS. CONTACTEZ VOTRE REPRESENTANT LOCAL.
Loading...
+ 4 hidden pages