Wilkerson F00 User Manual

INSTALLATION AND
MAINTENANCE SHEET
Filter Model F00 With
Variations and Accessories
83-210-000 REV A 1/97
EN# 970017 Printed in the U.S.A.
WARNING
SOME OF THE MATERIALS THAT WILL ATTACK
POLYCARBONATE PLASTIC BOWLS.
Acetaldehyde Chlorobenzene Methylene chloride Acetic acid (conc.) Chloroform Methylene salicylate Acetone Cresol Milk of lime (CaOH) Acrylonitrile Cyclohexanol Nitric acid (conc.) Ammonia Cyclohexanone Nitrobenzene Ammonium flouride Cyclohexene Nitrocellulose lacquer Ammonium hydroxide Dimethyl formamide Phenol Ammonium sulfide Diozane Phosphorous hydroxy Anaerobic adhesives Ethane tetrachloride chloride
and sealants Ethyl acetate Phosphorous trichloride Antifreeze Ethyl ether Propionic acid Benzene Ethylamine Pyridine Benzoic acid Ethylene chlorohydrin Sodium hydroxide Benzyl alcohol Ethylene dichloride Sodium sulfide Brake fluids Ethylene glycol Styrene Bromobenzene Formic acid (conc.) Sulfuric acid (conc.) Butyric acid Freon (refrig. & propell.) Sulphural chloride Carbolic acid Gasoline (high aromatic) Tetrahydronaphthalene Carbon disulfide Hydrazine Tiophene Carbon tetrachloride Hydrochloric acid (conc.) Toluene Caustic potash solution Lacquer thinner Turpentine Caustic soda solution Methyl alcohol Xylene
Perchlorethylene
and others
TRADE NAMES OF SOME COMPRESSOR OILS, RUBBER COMPOUNDS AND
OTHER MATERIALS THAT WILL ATTACK POLYCARBONATE PLASTIC BOWLS.
Atlas "Perma-Guard" National Compound #N11 Buna N "Nylock" VC-3 Cellulube #150 and #220 Parco #1306 Neoprene Crylex #5 cement *Permabond #910 *Eastman 910 Petron PD287 Garlock #98403 (polyurethane) Prestone Haskel #568-023 Pydraul AC Hilgard Co.'s hil phene Sears Regular Motor Oil Houghton & Co. oil #1120. #1130 & #1055 Sinclair oil "Lily White" Houtosafe 1000 Stauffer Chemical FYRQUEL #150 Kano Kroil Stillman #SR 269-75 (polyurethane) Keystone penetrating oil #2 Stillman #SR 513-70 (neoprene) *Loctite 271 Tannergas *Locite 290 Telar *Loctite 601 Tenneco anderol #495 & #500 oils Loctite Teflon-Sealant Titon Marvel Mystery Oil *Vibra-tite Minn. Rubber 366Y Zerex
*When in raw liquid form.
WE CANNOT POSSIBLY LIST ALL HARMFUL SUBSTANCES, SO CHECK WITH MOBAY
CHEMICAL OR THE GENERAL ELECTRIC OFFICE FOR FURTHER INFORMATION ON POLY-
CARBONATE PLASTIC.
CAUTION
EXCEPT as otherwise specified by the manufacturer, this product is specifically designed for com-
pressed air service, and use with any other fluid (liquid or gas) is a misapplication. For example, use with or injection of certain hazardous liquids or gases in the system (such as alcohol or liquid petro­leum gas) could be harmful to the unit or result in a combustible condition or hazardous external leakage. Manufacturer's warranties are void in the event of misapplication, and manufacturer assumes no responsibility for any resulting loss. Before using with fluids other than air, or for non­industrial applications, or for life support systems consult manufacturer for written approval.
See reverse side for Installation and
Maintenance Instructions.
O-RING
BAFFLE
KIT
TRANSPARENT
PLASTIC
BOWL
BODY
FILTER ELEMENT
AUTOMATIC PISTON DRAIN (optional)
METAL BOWL
CHECK VALVE
METAL BOWL GUARD (optional)
CHECK VALVE
®
OPERATIONS
INSTALLATION
1.Refer to the warning.
2.Install as close as possible to point where air is being used.
3.Install the unit with the air flowing through the body in the direction indicated by arrow.
4.Install the same pipe-size unit as the pipeline in use. Avoid using fittings, couplings, etc., that restrict air flow.
5.Do not install this unit on any application where the pressure drop will exceed 20 psi. Downstream from a quick-opening valve, for example, could cause a momentary drop in excess of 20 psi (1,4 bar).
6.Maximum inlet pressure and operating temperature ratings are: transparent plastic bowls, 150 psig (10 bar) and 125°F (52°C); metal bowls, 250 psig (17 bar) and 175°F (79°C).
MAINTENANCE
1. EACH TIME THE BOWL IS CLEANED OR THE FILTER ELEMENT REPLACED
A. Depressurize unit. B. Inspect and replace crazed, cracked, damaged or deteriorated
seals and bowls with original manufacturer's approved seals only.
C. Inspect bowl and replace crazed, damaged or deteriorated bowl with a
new bowl.
2. Remove element and clean periodically by tapping on a hard surface,
and blowing off with a blow gun.
3. IF UNIT IS EQUIPPED WITH A MANUAL DRAIN, drain sump whenever
water can be seen in bowl by pushing up on the valve stem.
4. Before placing the unit in service, make sure that the bowl and bowl
guard are securely locked in place.
REPAIR KITS AND REPLACEMENT PARTS
O-Ring Kit.............................................................................GRP-95-264
Filter Element Kit ..................................................................FRP-95-235
Baffle Kit ...............................................................................FRP-95-069
Automatic Piston Drain.........................................................GRP-95-584
Plastic Bowl with check valve...............................................GRP-96-310
Plastic Bowl ..........................................................................GRP-95-856
Metal Bowl with check valve.................................................GRP-96-506
Check Valve (for units w/o automatic
piston drain)..........................................................................GRP-96-102
Metal Bowl Guard.................................................................GRP-96-309
ACCESSORIES
Wall Mounting Bracket..........................................................GRP-95-754
Pipe Mounting Bracket .........................................................GRP-95-734