Wilkerson DE5 User Manual

INSTRUCTION MANUAL FOR
WILKERSON MODELS DE3, DE4 AND DE5
COMPACT HEATLESS AIR DRYERS
®
OPERATIONS
DE3 - DE5
This instruction manual covers the installation, operation, maintenance and troubleshooting guide for the Wilkerson compact heatless air dryers, models DE3, DE4 and DE5. These dryers are designed to be installed into a compressed air system, providing ultra-dry compressed air to moisture sensitive applications.
Instruction Manual / DE3, DE4 and DE5
Wilkerson Compact Heatless Air Dryers
C
D
A
H
K
L
J
F
E
G
MUFFLERS (OPTIONAL)
B
Model
Number
DE3 DE4
DE5
A
35.50
35.50
41.00
B
34.50
34.50
39.50
C
16.00
16.00
18.62
D
8.00
8.00
9.31
E
6.50
6.50
6.50
F
1.50
1.50
1.50
G
17.00
17.00
20.13
H
8.50
8.50
10.06
J
3.63
3.63
6.75
K
4.13
4.13
4.75
L
5.63
5.63
6.38
Outline Dimensions
Figure 1
DESCRIPTION OF OPERATION
Wilkerson DE series compact heatless air dryers employ the principles of pressure swing adsorption (PSA). The operation is fully automatic and relatively little maintenance is required.
The dryers utilize two identical desiccant towers, a metering orifice, two shuttle valves, and two 2-way AC operated solenoid valves controlled by a solid state electronic timer. Wet air at line pressure enters and flows through one of the towers where nearly all the water vapor is adsorbed while the other tower is being regenerated. Arepressurization period follows the regeneration period. Every 60 seconds, the process is reversed, providing a continuous flow of dry air.
In the flow schematic shown below, Valve A (closed, de-energized) and Valve B (open, energized) allow the inlet shuttle valve to direct the inlet air to flow into Tower A (drying). A portion of the dry outlet air is allowed to flow through the outlet shuttle valve purge orifice into Tower B. This dry purge air expands to nearly atmospheric pressure, sweeping the water out of the desiccant as it flows through Tower B (regenerating) and out of the Valve B (energized) exhaust port. The timer controls the cycling of normally closed solenoid valves.
The orifices are fixed and are sized by the factory based on flow, pressure and dew point required.
Flow Schematic
Figure 2
Instruction Manual / DE3, DE4 and DE5
Wilkerson Compact Heatless Air Dryers
EXHAUST
SOLENOID
VALVE A
INLET
SHUTTLE
VALVE
DESICCANT
TOWER A
OUTLET SHUTTLE
VALVE WITH
PURGE ORIFICE
DESICCANT
TOWER B
DRY AIR
TO APPLICA TION
EXHAUST
SOLENOID
VALVE B
PURGE AIR EXHAUST
WET AIR IN
DE3, DE4 and DE5
DESICCANT
TOWER A
EXHAUST
SOLENOID
V ALVE A
EXHAUST
SOLENOID
VALVE B
PURGE AIR EXHAUST
DESICCANT
TOWER B
DRY AIR
TO APPLICA TION
OUTLET SHUTTLE
VALVE WITH
PURGE ORIFICE
INLET
SHUTTLE
VALVE
WET AIR IN
INSTALLATION AND OPERATION
NOTE:
Wilkerson DE series compact heatless dryers have been thoroughly inspected and tested at the factory and are in proper working condition.
A. Initial Inspection – Remove the air dryer from the shipping carton. Inspect the exterior and
remove the electrical cover and inspect the interior components for any shipping damage.
NOTE:
Any damage noticed at this time must be brought to the immediate attention of the carrier and a freight claim must be filed.
B. Warranty – Please read this instruction manual carefully before installing the air dryer.
Failure to follow proper instructions could result in damage to the equipment and may void the product warranty.
EXCEPT as otherwise specified by the manufacturer, this product is specifically designed for compressed air service and use with any other gas or liquid is a misapplication. Use with or injection of certain hazardous liquids or gases in the system (i.e., alcohol or liquid petroleum gas) could be harmful to the unit and result in a combustible condition or cause hazardous external leakage. Manufacturers' warranties are void in the event of a misapplication and manufacturer assumes NO RESPONSIBILITY for any resulting loss. Before using equipment with fluids or gases other than air, or for non-industrial applications, consult Wilkerson Corporation for written approval.
C. Installation/Mounting – Four mounting holes are provided for wall mounting of Models DE3,
DE4 and DE5. All dryers require a clean ambient environment for proper operation. Normally, most locations where ambient temperatures range between 40˚F and 125˚F are suitable for installation since drying efficiency is more dependent on the temperature of the compressed air flowing through the unit. Operating a unit at temperatures which could result in freezing may cause damage to the dryer. Do not operate at temperatures so low that freezing is a possibility.
1. Install dryer where ambient temperatures are between 40°F (4.4°C) and 125°F (52°C).
2. Mount dryer in a vertical position.
3. Piping connections: For maximum flow, INLET and OUTLET piping should be schedule 40 pipe or equivalent I.D. tubing. DE3, DE4 and DE5 inlet and outlet ports are 1/2" female, NPT, purge porting is 1/2" female, NPT.
Instruction Manual / DE3, DE4 and DE5
Wilkerson Compact Heatless Air Dryers
CAUTION:
!
!
NOTE
If purge air is required to be piped to a remote location, it is necessary to use oversized tubing to prevent back-pressure. Restricting the purge flow can cause the dryer to malfunction.
4. Use Teflon tape or pipe sealant on threads. Check all air connections for leakage, using soap solution prior to putting dryer into permanent service.
5. It is recommended that a bypass line with shut-off valves be installed to provide constant air flow to the system, should the dryer require servicing.
6. Always install a 5-micron particulate prefilter and a coalescing filter upstream to remove entrained particulates, moisture and oil. A0.5-micron afterfilter should be installed down­stream to remove any desiccant dust that may migrate from the desiccant towers.
Factory Recommended Dryer Installation
Figure 3
D. Operating Specifications – The DE3, DE4 and DE5 series compact heatless dryers can
be sized to operate from 40 to 150 PSIG (2,7 to 10,3 bar).
1. The dryers must be operated in accordance with the factory sizing charts and original cus­tomer requirements in order to achieve desired dewpoints. Inlet pressure, inlet tempera­ture, and outlet flow conditions are always specified when purchased.
2. Maximum inlet air temperature is 125°F (52°C).
3. Do not operate dryers in temperatures so low that freezing is a possibility.
E. Electrical Connections – Before wiring, check the dryer nameplate for electrical characteris-
tics. Standard electrical characteristics are 115 Volt, 50/60Hz operation. Models operating on 230 Volt, 50/60Hz operation are available.
1. IMPORTANT! No overload protection is provided in the dryer and unit should be wired into a protected circuit. Aknockout hole with romex connector is provided for electrical connection.
Instruction Manual / DE3, DE4 and DE5
Wilkerson Compact Heatless Air Dryers
5-MICRON PREFILTER WITH AUTO
DRAIN
MICROALESCER
OPTIONAL
REGULATOR
SHUT-OFF
VALVE
AIR DRYER
WITH MOISTURE
INDICATOR
BYPASS LINE
BYPASS SHUT-OFF VALVE
SHUT-OFF
VALVE
MOISTURE INDICATOR
0.5-MICRON
POSTFILTER
OPTIONAL
REGULATOR
!