WMR-300 Operation Manual
Operation
Wiligear Deliberant Group WMR-300 is a high power miniPCI card to be used in
outdoor wireless systems. Please use the following instructions when using this
card. This card is meant to be operated (and used) by system integrators who
are aware of the regulatory requirements in the area it is being used. The
following instructions need to be followed while using the card
1) Before inserting the card in a host PC board, please power down the host
PC board first
2) The antenna port (MMCX connector) should be connected to the
appropriate load or antenna before powering up the host board. Lack of
Antenna (or load) while the WMR-300 is powered up will cause severe
damage to the card
3) Please make sure any person handling the card with bare hands follows
proper ESD precautions. Improper handling could cause ESD damage.
4) The card should not be tampered or modified in any way. Tampering or
modification could cause the card to fail standard tests
FCC Information
Electronic Emission Notices
This device complies with CFR 47 Part 15 of the FCC rules.
Operation is subject to the following two conditions:
· This device may not cause harmful interference.
·
This device must accept any interference received, including interference that may cause
undesired operation.
FCC Frequency Interference Statement
This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to CFR47 Part 15. These limits are designed to provide
reasonable protection against harmful interference when the equipment is
operated in a residential environment, not withstanding use in commercial,
business and industrial environment.
This equipment generates, uses, and can radiate radio frequency energy and, if
not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. There is no guarantee that interference
will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning
the equipment off and on, the user is encouraged to try to correct the interference
by one or more of the following measures:
· Reorient or relocate the receiving antenna.
Increase the separation between the equi pment and receiver.
·
·
Connect the equipment into an outlet on a circuit different from where the receiver is connected.
Wilibox Deliberant Group, 1440 Dutch Valley Place STE 1155, Atlanta GA 30324 USA Ph:
800.742.9865
· Consult the dealer or an experienced radio/T V technician for help.
Changes or modifications to this equipment not expressly approved by the party
responsible for compliance could void the user’s authority to operate the
equipment.
FCC Radiation Exposure Statement
To comply with FCC RF exposure requirements in section 1.1307, a minimum
separation distance of 3.9 feet is required between the antenna and all
occupational persons, and a minimum separation distance of 8.7 feet is required
between the antenna and all public persons.
Antenna Installation
WARNING: It is installer’s responsibility to ensure that when using the authorized
antennas in the United States (or where FCC rules apply), only those antennas
certified with the product are used. The use of any antenna other than those
certified with the product is expressly forbidden in accordance to FCC rules
CFR47 part 15.204. The installer should configure the output power level of
antennas, according to country regulations and per antenna type. Professional
installation is required of equipment with connectors to ensure compliance with
health and safety issues.
Antenna Compliance
Note to professional installer:
Total EIRP for the WMR-300 module + antenna less cable losses must not
exceed 36dBm. If the sum of WMR-300 output power and antenna gain less the
cable loss exceeds 36dBm WMR-300, the output power must be reduced in the
software to comply with the 36 dBm requirements.
The WMR-300 radio module has been tested and certified with the following
antennas:
• Omni (8dBi) – HyperGain HG908U-PRO
• Grid (18dBi) – HyperGain HG918G
• Yagi (13dBi) – HyperGain HG913Y
• Panel (12.5dBi) – ARC-IA0913b01
Any antenna of same make and lower gain than those listed above may be used
in compliance with certification.