Wilden P8, PX8 Engineering, Operation & Maintenance

P8/PX8
Original™ Series PLASTIC Pumps
Engineering Operation & Maintenance
Simplify your process
WIL-10131-E-01
TABLE OF CONTENTS
SECTION 1 CAUTIONS—READ FIRST! . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
SECTION 2 WILDEN PUMP DESIGNATION SYSTEM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
SECTION 3 HOW IT WORKS—PUMP & AIR DISTRIBUTION SYSTEM . . . . . . . . . . . . . . . . 3
SECTION 4 DIMENSIONAL DRAWINGS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
SECTION 5 PERFORMANCE
A. P8 PLASTIC Performance Curves
Rubber-Fitted . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
TPE-Fitted . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
PTFE-Fitted . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Ultra-Flex™-Fitted . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Suction Lift Curve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
B. PX8 PLASTIC Performance
Operating Principal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
How to Use this EMS Curve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Performance Curves
Rubber-Fitted . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
TPE-Fitted . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
PTFE-Fitted . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
Ultra-Flex™-Fitted . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Suction Lift Curve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
SECTION 6 SUGGESTED INSTALLATION, OPERATION & TROUBLESHOOTING . . . . . . . 20
SECTION 7 DISASSEMBLY/REASSEMBLY
A. Pump Disassembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
B. Pro-Flo® Air Valve / Center Section Disassembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
C. Pro-Flo X
TM
Air Valve / Center Section Disassembly . . . . . . . . . . . . . . . . . . . . . . . . . .28
D. Reassembly Hints & Tips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30
E. PTFE Gasket Kit Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31
SECTION 8 EXPLODED VIEW & PARTS LISTING
P8 Rubber/TPE-Fitted . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32
P8 PTFE/Ultra-Flex™-Fitted . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34
PX8 Rubber/TPE-Fitted . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36
PX8 PTFE/Ultra-Flex™-Fitted . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38
SECTION 9 ELASTOMER OPTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40
O
z
o
I
I
n
e
&
I
s
s
a
l
C
NON
U.S. Clean Air Act
Amendments of 1990
D
e
p
l
e
USE
u
S
t
i
n
g
s
e
c
n
a
t
s
b
Section 1
CAUTIONS – READ FIRST
CAUTION: Do not apply compressed air to the exhaust port — pump will not function.
CAUTION: Do not over lubricate air supply — excess lubrication will reduce pump performance.
TEMPERATURE LIMITS:
Polypropylene 0°C to 79°C 32°F to 175°F PVDF –12°C to 107°C 10°F to 225°F Neoprene –17.7°C to 93.3°C 0°F to 200°F Buna-N –12.2°C to 82.2°C 10°F to 180°F EPDM –51.1°C to 137.8°C –60°F to 280°F Viton Wil-Flex™ –40°C to 107.2°C –40°F to 225°F Saniflex™ –28.9°C to 104.4°C –20°F to 220°F Polyurethane –12.2°C to 65.6°C 10°F to 150°F Tetra-Flex™ 4.4°C to 107.2°C 40°F to 225°F PTFE 4.4°C to 104.4°C 40°F to 220°F
®
–40°C to 176.7°C –40°F to 350°F
CAUTION: When choosing pump materials, be sure to check the temperature limits for all wetted compo­nents. Example: Viton (350°F) but polypropylene has a maximum limit of only 79°C (175°F).
CAUTION: Maximum temperature limits are based upon mechanical stress only. Certain chemicals will significantly reduce maximum safe operating tempera­tures. Consult engineering guide for chemical compat­ibility and temperature limits.
CAUTION: Always wear safety glasses when operat­ing pump. If diaphragm rupture occurs, material being pumped may be forced out air exhaust.
Plastic series pumps are made of virgin plastic and are not UV stabilized. Direct sunlight for prolonged periods can cause deterioration of plastics.
WARNING: Prevention of static sparking — If static sparking occurs, fire or explosion could result. Pump, valves, and containers must be grounded when handling flammable fluids and whenever discharge of static electricity is a hazard. To ground the Wilden “Champ,” all clamp bands must be grounded to a proper grounding point.
®
has a maximum limit of 176.7°C
CAUTION: Do not exceed 8.6 bar (125 psig) air supply pressure.
CAUTION: Before any maintenance or repair is attempted, the compressed air line to the pump should be disconnected and all air pressure allowed to bleed from pump. Disconnect all intake, discharge and air lines. Drain the pump by turning it upside down and allowing any fluid to flow into a suitable container.
CAUTION: Blow out air line for 10 to 20 seconds before attaching to pump to make sure all pipeline debris is clear. Use an in-line air filter. A 5µ micron air filter is recommended.
NOTE: When installing PTFE diaphragms, it is impor­tant to tighten outer pistons simultaneously (turning in opposite directions) to ensure tight fit.
NOTE: P8 and PX8 PVDF pumps come standard from the factory with expanded PTFE gaskets installed in the diaphragm bead of the liquid chamber, in the T-section and in the ball and seat area. PTFE gaskets cannot be re-used. Consult PS-TG for installation instructions during reassembly.
NOTE: Before starting disassembly, mark a line from each liquid chamber to its corresponding air cham­ber. This line will assist in proper alignment during reassembly.
CAUTION: The P8 Plastic pump is not submersible. If your application requires your pump to be submersed, the PX8 model can be used with the submersible option.
CAUTION: Pumps should be flushed thoroughly with water before installation into process line.
CAUTION: Tighten all hardware prior to installation.
WIL-10131-E-01 1 WILDEN PUMP & ENGINEERING, LLC
Section 2

WILDEN PUMP DESIGNATION SYSTEM

P8/PX8 ORIGINAL™ PLASTIC
51 mm (2") Pump Maximum Flow Rate: 587 lpm (155 gpm)
MATERIAL CODES
MODEL
P8 = PRO-FLO PX8 = PRO-FLO X
WETTED PARTS & OUTER PISTON
KK = PVDF / PVDF PK = POLYPROPYLENE /
AIR CHAMBERS
A = ALUMINUM C = S = STAINLESS STEEL
CENTER BLOCK
P = POLYPROPYLENE
AIR VALVE
P = POLYPROPYLENE L = ACETAL (P8 only)
LEGEND
P8 /XXXXX / XXX / XX /XXX / XXXX
MODEL
®
TM
PVDF
PTFE COATED ALUMINUM
DIAPHRAGMS
VALVE BALLS
AIR VALVE
CENTER BLOCK
AIR CHAMBERS
WETTED PARTS & OUTER PISTON
DIAPHRAGMS
BNS = BUNA-N (Red Dot) BNU = BUNA-N, ULTRA­ FLEX™ EPS = EPDM (Blue Dot) EPU = EPDM, ULTRA­ FLEX™ FSS = SANIFLEX™
[Hytrel® (Cream)] NES = NEOPRENE (Green Dot) NEU = NEOPRENE, ULTRA­ FLEX™ PUS = POLYURETHANE (Clear) TEU = PTFE W/EPDM BACK-UP (White) TNU = PTFE W/NEOPRENE BACK-UP (White) VTS = VITON® (White Dot) VTU = VITON®, ULTRA­ FLEX™ WFS = WIL-FLEX™
[Santoprene®
(Orange Dot)]
O-RINGS
VALVE SEAT
VALVE BALL
SPECIALTY CODE
(if applicable)
BN = BUNA-N (Red Dot) EP = EPDM (Blue Dot) NE = NEOPRENE (Green Dot) PU = POLYURETHANE (Brown) TF = PTFE (White) VT = VITON® (White Dot) WF = WIL-FLEX™
[Santoprene® (Orange Dot)]
VALVE SEAT
K = PVDF P = POLYPROPYLENE
VALVE SEAT O-RING
BN = BUNA-N (Red Dot) PU = POLYURETHANE
(Brown) TV = PTFE ENCAP. VITON WF = WIL-FLEX™
[Santoprene® (Orange
Dot)]
®
SPECIALTY CODES
0100 Wil-Gard II™ 110V 0102 Wil-Gard II™, sensor wires ONLY 0103 Wil-Gard II™ 220V 0206 PFA coated hardware, Wil-Gard II™ sensor wires only 0502 PFA coated hardware
NOTE: MOST ELASTOMERIC MATERIALS USE COLORED DOTS FOR INDENTIFICATION.
®
is a registered trademark of Solvay.
Halar Viton® is a registered trademark of DuPont Dow Elastomers.
WILDEN PUMP & ENGINEERING, LLC 2 WIL-10131-E-01
0513 SS outer pistons 0560 Split manifold 0561 Split manifold, PFA coated hardware 0563 Split manifold, discharge only 0564 Split manifold, inlet only
0608 PFA coated hardware, Wil-
Gard II™ 220V 0660 Split manifold, Wil-Gard II™ 110V 0661 Split manifold, PFA coated
hardware, Wil-Gard II™ 110V
Section 3
HOW IT WORKS
The Wilden diaphragm pump is an air-operated, positive displacement, self-priming pump. These drawings show flow pattern through the pump upon its initial stroke. It is assumed the pump has no fluid in it prior to its initial stroke.
RIGHT STROKE MID STROKE LEFT STROKE
FIGURE 1 The air valve directs pressurized air to the back side of diaphragm A. The compressed air is applied directly to the liquid column separated by elastomeric diaphragms. The diaphragm acts as a separation membrane between the compressed air and liquid, balancing the load and removing mechanical stress from the diaphragm. The compressed air moves the diaphragm away from the center block of the pump. The opposite diaphragm is pulled in by the shaft connected to the pressurized diaphragm. Diaphragm B is on its suction stroke; air behind the diaphragm has been forced out to the atmosphere through the exhaust port of the pump. The movement of diaphragm B toward the center block of the pump creates a vacuum within chamber B. Atmospheric pressure forces fluid into the inlet manifold forcing the inlet valve ball off its seat. Liquid is free to move past the inlet valve ball and fill the liquid chamber (see shaded area).
FIGURE 2 When the pressurized diaphragm, diaphragm A, reaches the limit of its discharge stroke, the air valve redirects pressurized air to the back side of diaphragm B. The pressurized air forces diaphragm B away from the center block while pulling diaphragm A to the center block. Diaphragm B is now on its discharge stroke. Diaphragm B forces the inlet valve ball onto its seat due to the hydraulic forces developed in the liquid chamber and manifold of the pump. These same hydraulic forces lift the discharge valve ball off its seat, while the opposite discharge valve ball is forced onto its seat, forcing fluid to flow through the pump discharge. The movement of diaphragm A toward the center block of the pump creates a vacuum within liquid chamber A. Atmospheric pressure forces fluid into the inlet manifold of the pump. The inlet valve ball is forced off its seat allowing the fluid being pumped to fill the liquid chamber.
FIGURE 3 At completion of the stroke, the air valve again redirects air to the back side of diaphragm A, which starts diaphragm B on its exhaust stroke. As the pump reaches its original starting point, each diaphragm has gone through one exhaust and one discharge stroke. This constitutes one complete pumping cycle. The pump may take several cycles to completely prime depending on the conditions of the application.
HOW IT WORKS—AIR DISTRIBUTION SYSTEM
The Pro-Flo® patented air distribution system incorporates three moving parts: the air valve spool, the pilot spool, and the main shaft/diaphragm assembly. The heart of the system is the air valve spool and air valve. As shown in Figure 1, this valve design incorporates an unbalanced spool. The smaller end of the spool is pressur­ized continuously, while the large end is alternately pressurized and exhausted to move the spool. The spool directs pressur­ized air to one chamber while exhausting the other. The air causes the main shaft/ diaphragm assembly to shift to one side — discharging liquid on one side and pulling liquid in on the other side. When the shaft reaches the end of its stroke, it
Figure 1
WIL-10131-E-01 3 WILDEN PUMP & ENGINEERING, LLC
actuates the pilot spool, which pressur­izes and exhausts the large end of the air valve spool. The pump then changes direction and the same process occurs in the opposite direction, thus reciprocating the pump.
Section 4

DIMENSIONAL DRAWINGS

P8 Plastic
DIMENSIONS
ITEM METRIC (mm) STANDARD (inch)
A 490 19.3 B 76 3.0 C 414 16.3 D 693 27.3 E 770 30.3 F 89 3.5 G 417 16.4 H 333 13.1 J 381 15.0 K 307 12.1
L 227 8.9 M 254 10.0 N 15 0.6
METRIC (mm) STANDARD (inch) P 122 DIA. 4.8 DIA. R 152 DIA. 6.0 DIA. S 20 DIA.
0.8 DIA.
PX8 Plastic
DIMENSIONS
ITEM METRIC (mm) STANDARD (inch)
A 490 19.3 B 76 3.0 C 414 16.3 D 693 27.3 E 770 30.3 F 89 3.5 G 422 16.6 H 173 6.8 J 356 14.0 K 447 17.6 L 381 15.0
M 307 12.1
N 227 8.9 P 254 10.0 R15 .6
DIN/ANSI COMBO
S 122 DIA. 4.8 DIA. T 155 DIA. 6.1 DIA. U 20 DIA. .8 DIA.
WILDEN PUMP & ENGINEERING, LLC 4 WIL-10131-E-01
Section 5A

PERFORMANCE

P8 PLASTIC

RUBBER-FITTED

Height .................................. 770 mm (30.3")
Width ................................... 490 mm (19.3")
Depth ..................................333 mm (13.1")
Est. Ship Weight ......
Air Inlet .................................... 13 mm (1/2")
Inlet ............................................ 51 mm (2")
Outlet .........................................51 mm (2")
Suction Lift ........................... 7.0 m Dry (23')
Displacement per
Stroke ......................... 2.91 l (0.77 gal.)
Max. Flow Rate ............... 587 lpm (155 gpm)
Max. Size Solids .....................6.4 mm (1/4")
1
Displacement per stroke was calculated at 4.8 bar (70 psig) air inlet pressure against a 2 bar (30 psig) head pressure.
Example: To pump 291.5 lpm (77 gpm) against a discharge pressure head of 2.0 bar (30 psig) requires 4.1 bar (60 psig) and 68
3
Nm
/h (40 scfm ) air consumption. (See dot
on chart.)
Caution: Do not exceed 8.6 bar (125 psig) air supply pressure.
Polypropylene
34 kg (75 lbs)
PVDF
43 kg (95 lbs)
9.45 m Wet (31')
1
Flow rates indicated on chart were determined by pumping water.
For optimum life and performance, pumps should be specified so that daily operation parameters will fall in the center of the pump performance curve.
P8 PLASTIC

TPE-FITTED

Height .................................. 770 mm (30.3")
Width ................................... 490 mm (19.3")
Depth ..................................333 mm (13.1")
Est. Ship Weight ......
Air Inlet .................................... 13 mm (1/2")
Inlet ............................................ 51 mm (2")
Outlet .........................................51 mm (2")
Suction Lift ......................... 5.18 m Dry (17')
Displacement per
Stroke .......................... 2.91 l (0.77 gal.)
Max. Flow Rate ............... 575 lpm (152 gpm)
Max. Size Solids .....................6.4 mm (1/4")
1
Displacement per stroke was calculated at 4.8 bar (70 psig) air inlet pressure against a 2 bar (30 psig) head pressure.
Example: To pump 283.9 lpm (75 gpm) against a discharge pressure head of 2.1 bar (30 psig) requires 4.1 bar (60 psig) and
3
76.5 Nm
/h (45 scfm) air consumption. (See
dot on chart.)
Caution: Do not exceed 8.6 bar (125 psig ) air supply pressure.
Polypropylene
34 kg (75 lbs)
PVDF
43 kg (95 lbs)
9.45 m Wet (31')
1
Flow rates indicated on chart were determined by pumping water.
For optimum life and performance, pumps should be specified so that daily operation parameters will fall in the center of the pump performance curve.
WIL-10131-E-01 5 WILDEN PUMP & ENGINEERING, LLC
PERFORMANCE
P8 PLASTIC

PTFE-FITTED

Height .................................. 770 mm (30.3")
Width ................................... 490 mm (19.3")
Depth ..................................333 mm (13.1")
Est. Ship Weight ......
Air Inlet .................................... 13 mm (1/2")
Inlet ............................................ 51 mm (2")
Outlet .........................................51 mm (2")
Suction Lift ......................... 4.27 m Dry (14')
Displacement per
Stroke ...........................0.53 l (0.47 gal.)
Max. Flow Rate ............... 481 lpm (127 gpm)
Max. Size Solids .....................6.4 mm (1/4")
1
Displacement per stroke was calculated at 4.8 bar (70 psig) air inlet pressure against a 2 bar (30 psig) head pressure.
Example: To pump 238.5 lpm (63 gpm) against a discharge pressure head of 2.0 bar (30 psig) requires 4.1 bar (60 psig) and 45
3
Nm
/h (55 scfm) air consumption. (See dot
on chart.)
Caution: Do not exceed 8.6 bar (125 psig) air supply pressure.
Polypropylene
34 kg (75 lbs)
PVDF
43 kg (95 lbs)
9.45 m Wet (31')
1
Flow rates indicated on chart were determined by pumping water.
For optimum life and performance, pumps should be specified so that daily operation parameters will fall in the center of the pump performance curve.
P8 PLASTIC
ULTRA-FLEX
Height .................................. 770 mm (30.3")
Width ................................... 490 mm (19.3")
Depth ..................................333 mm (13.1")
Est. Ship Weight ......
Air Inlet .................................... 13 mm (1/2")
Inlet ............................................ 51 mm (2")
Outlet .........................................51 mm (2")
Suction Lift ......................... 4.88 m Dry (16')
Displacement per
Stroke ......................... 2.12 l (0.56 gal.)
Max. Flow Rate ............... 560 lpm (148 gpm)
Max. Size Solids .....................6.4 mm (1/4")
1
Displacement per stroke was calculated at 4.8 bar (70 psig) air inlet pressure against a 2 bar (30 psig) head pressure.
Example: To pump 257.4 lpm (68 gpm) against a discharge pressure head of 2.0 bar (30 psig) requires 4.1 bar (60 psig) and
3
76.5 Nm dot on chart.)
Caution: Do not exceed 8.6 bar (125 psig) air supply pressure.
/h (45 scfm) air consumption. (See
TM
-FITTED
Polypropylene
34 kg (75 lbs)
PVDF
43 kg (95 lbs)
8.84 m Wet (29')
1
[LPM]
Water Discharge Flow Rates
Flow rates indicated on chart were determined by pumping water.
For optimum life and performance, pumps should be specified so that daily operation parameters will fall in the center of the pump performance curve.
WILDEN PUMP & ENGINEERING, LLC 6 WIL-10131-E-01
Section 5B
SUCTION LIFT CURVES
P8 PLASTIC SUCTION LIFT CAPABILITY
PTFE Diaphragms
WIL-10131-E-01 7 WILDEN PUMP & ENGINEERING, LLC
NOTES
WILDEN PUMP & ENGINEERING, LLC 8 WIL-10131-E-01
PX8
P L A S T I C

PX8 PLASTIC PERFORMANCE

Section 5B
Pro-Flo X
The Pro-Flo X™ air distribution system with the
revolutionary Effi ciency Management System (EMS)
offers fl exibility never before seen in the world of
AODD pumps. The
patent-pending EMS
is simple and easy
to use. With the
turn of an integrated
TM

Operating Principal

control dial, the operator can select the optimal
balance of fl ow and effi ciency that best meets the
application needs. Pro-Flo X™ provides higher
performance, lower
operational costs
and fl exibility that
exceeds previous
industry standards.
AIR CONSUMPTION
$
$
$
Turning the dial changes the relationship between air inlet and exhaust porting.
WILDEN PUMP & ENGINEERING, LLC 10 PX8 Plastic Performance
Each dial setting represents an entirely different fl ow curve
Pro-Flo X™ pumps are shipped from the factory on setting 4, which is the highest fl ow rate setting possible
Moving the dial from setting 4 causes a decrease in fl ow and an even greater decrease in air consumption.
When the air consumption decreases more than the fl ow rate, effi ciency is improved and operating costs are reduced.
Example 1
HOW TO USE THIS EMS CURVE
SETTING 4 PERFORMANCE CURVE
Figure 1 Figure 2
Example data point = Example data point =
This is an example showing how to determine fl ow rate and air consumption for your Pro-Flo X™ pump using the Effi cien­cy Management System (EMS) curve and the performance curve. For this example we will be using 4.1 bar (60 psig) inlet air pressure and 2.8 bar (40 psig) discharge pressure and EMS setting 2.
Step 1:
Identifying performance at setting 4. Locate
the curve that represents the fl ow rate of the pump with 4.1 bar (60 psig) air inlet pressure. Mark the point where this curve crosses the horizontal line representing 2.8 bar (40 psig) discharge pressure. (Figure 1). After locating your performance point on the fl ow curve, draw a vertical line downward until reaching the bottom scale on the chart. Identify the fl ow rate (in this case, 8.2 gpm). Observe location of performance point relative to air consump­tion curves and approximate air consumption value (in this case, 9.8 scfm).
8.2
GPM
curve, draw vertical lines downward until reaching the bottom scale on the chart. This identifi es the fl ow X Factor (in this case, 0.58) and air X Factor (in this case, 0.48).
Step 3:
Calculating performance for specific EMS
setting. Multiply the fl ow rate (8.2 gpm)
obtained in Step 1 by the fl ow X Factor multi­plier (0.58) in Step 2 to determine the fl ow rate at EMS setting 2. Multiply the air consump­tion (9.8 scfm) obtained in Step 1 by the air X Factor multiplier (0.48) in Step 2 to deter­mine the air consumption at EMS setting 2 (Figure 3).
gpm
8.2 .58
gpm
4.8
0.58
0.48
(fl ow rate for Setting 4)
(Flow X Factor setting 2)
(Flow rate for setting 2)
EMS CURVE
fl ow multiplier
air multiplier
Step 2:
Determining flow and air X Factors. Locate your discharge pressure (40 psig) on the verti­cal axis of the EMS curve (Figure 2). Follow along the 2.8 bar (40 psig) horizontal line until intersecting both fl ow and air curves for your desired EMS setting (in this case, setting 2). Mark the points where the EMS curves inter­sect the horizontal discharge pressure line. After locating your EMS points on the EMS
PX8 Plastic Performance 11 WILDEN PUMP & ENGINEERING, LLC
Figure 3
The fl ow rate and air consumption at Setting 2 are found to be 18.2 lpm (4.8 gpm) and 7.9 Nm3/h (4.7 scfm) respectively.
9.8 .48
4.7
scfm
(air consumption for setting 4) (Air X Factor setting 2)
scfm
(air consumption for setting 2)
Loading...
+ 30 hidden pages