91397 Rev B 09/17 Page 6 of 7
The Settings menu can be accessed by pressing and holding down the SQUARE button for two seconds.
Navigate the menu with the arrow buttons. Press the SQUARE button to select a menu item.
2.3.1 Setup Wizard
Setup Wizard allows the machine running speed to be entered and the ISO alarm levels
to be set automatically according to the size and type of machine to be monitored.
The first screen shows the currently selected running speed in the pre-selected units (Hz
or RPM). Change the running speed with the arrow buttons.
Press the SQUARE button again to select machine type (motor or pump). If motor is
selected the size must be selected (under or over 300kW). If pump is selected, specify
whether it has an integrated or external drive unit.
Selecting the machine type and size allows the ISO alarm levels to be set accordingly, as
does specifying the type of mounting (rigid or flexible).
Unless a machine is bolted to a concrete floor, its mounting should be considered flexible.
Most motors and pumps are mounted on some kind of frame or structure and should be
considered flexibly mounted.
2.3.2 Load and Save readings
Press the SQUARE button to select Load & Save. Save Reading opens a screen which
allows the user to choose from one of three Memories in which to save the reading.
Selecting Load Reading lets the user load a previously saved reading for further review.
Demo Data loads two pre-stored demonstration vibraion data.
2.3.3 Advanced settings
Use the arrow buttons to scroll through the options, and the SQUARE button to select.
BDU settings
Change the alarm levels at which the BDU readings change color
Units
Sets velocity readings to be displayed in mm/s or inch/s.
Sets Run Speed to Hertz, RPM, or CPM.
2.3.3 Device settings
Use the arrow buttons to scroll through the options, and the SQUARE button to select.
Auto Off Time
Can be set from 1 to 60 minutes, in one minute increments
Brightness