WIKA DG-10 User Manual [en, de, es, fr]

Operating instructions Betriebsanleitung Mode d'emploi Manual de instrucciones
Digital pressure gauge model DG-10
Manomètre digital type DG-10
Manómetro digitales modelo DG-10
Digital pressure gauge model DG-10
GB
D
F
E
GB
Operating instructions model DG-10 Page 3 - 28
D
Betriebsanleitung Typ DG-10 Seite 29 - 56
F
Mode d‘emploi type DG-10 Page 57 - 82
E
Manual de instrucciones modelo DG-10 Página 83 - 109
© 2012 WIKA Alexander Wiegand SE & Co. KG All rights reserved. / Alle Rechte vorbehalten. WIKA® is a registered trademark in various countries. WIKA® ist eine geschützte Marke in verschiedenen Ländern.
Prior to starting any work, read the operating instructions! Keep for later use!
Vor Beginn aller Arbeiten Betriebsanleitung lesen! Zum späteren Gebrauch aufbewahren!
Lire le mode d'emploi avant de commencer toute opération ! A conserver pour une utilisation ultérieure !
¡Leer el manual de instrucciones antes de comenzar cualquier trabajo! ¡Guardar el manual para una eventual consulta posterior!
2 WIKA operating instructions digital gauge, model DG-10
11250313.03 09/2012 GB/D/F/E
Contents
Contents
1. General information 4
2. Safety 6
3. Specications 9
4. Design and function 13
5. Transport, packaging and storage 13
6. Commissioning, operation 14
7. Maintenance and cleaning 25
8. Faults 26
9. Dismounting, return and disposal 27
10. Accessories 28
Appendix 1: EC Declaration of conformity model DG-10 55
GB
Declarations of conformity can be found online at www.wika.com.
11250313.03 09/2012 GB/D/F/E
3WIKA operating instructions digital pressure gauge, model DG-10
1. General information
1. General information
The digital pressure gauge described in the operating instructions has been designed and
GB
manufactured using state-of-the-art technology. All components are subject to stringent quality and environmental criteria during production. Our management systems are certied to ISO 9001 and ISO 14001.
These operating instructions contain important information on handling the instrument. Working safely requires that all safety instructions and work instructions are observed.
Observe the relevant local accident prevention regulations and general safety regulations for the instrument's range of use.
The operating instructions are part of the product and must be kept in the immediate vicinity of the instrument and readily accessible to skilled personnel at any time.
Skilled personnel must have carefully read and understood the operating instructions prior to beginning any work.
The manufacturer's liability is void in the case of any damage caused by using the product contrary to its intended use, non-compliance with these operating instructions, assignment of insuciently qualied skilled personnel or unauthorised modications to the instrument.
The general terms and conditions contained in the sales documentation shall apply.
Subject to technical modications.
Further information:
- Internet address: www.wika.de / www.wika.com
- Relevant data sheet: PE 81.66
- Application consultant:
Tel.: (+49) 9372/132-8976 Fax: (+49) 9372/132-8008976 E-mail: support-tronic@wika.de
4 WIKA operating instructions digital pressure gauge, model DG-10
11250313.03 09/2012 GB/D/F/E
1. General information
Explanation of symbols
WARNING!
... indicates a potentially dangerous situation that can result in serious injury or death, if not avoided.
CAUTION!
... indicates a potentially dangerous situation that can result in light injuries or damage to the equipment or the environment, if not avoided.
Information
... points out useful tips, recommendations and information for ecient and trouble-free operation.
GB
11250313.03 09/2012 GB/D/F/E
5WIKA operating instructions digital pressure gauge, model DG-10
2. Safety
2. Safety
WARNING!
GB
2.1 Intended use
The digital pressure gauge acts as the display for the applied pressure. The pressure value is displayed via a digital indicator.
The instrument has been designed and built solely for the intended use described here, and may only be used accordingly.
The technical specications contained in these operating instructions must be observed. Improper handling or operation of the digital pressure gauge outside of its technical specications requires the digital pressure gauge to be taken out of service immediately and inspected by an authorised WIKA service engineer.
Before installation, commissioning and operation, ensure that the appropriate digital pressure gauge has been selected in terms of measuring range, design and specic measuring conditions. Non-observance can result in serious injury and/or damage to the equipment.
WARNING!
Open the connections only after the system has been depressurised.
Observe the working conditions in accordance with chapter 3 "Specications".
Always operate the digital pressure gauge within the overpressure limit.
Further important safety instructions can be found in the individual chapters of these operating instructions.
The manufacturer shall not be liable for claims of any type based on operation contrary to the intended use.
6 WIKA operating instructions digital pressure gauge, model DG-10
11250313.03 09/2012 GB/D/F/E
2. Safety
2.2 Personnel qualication
WARNING! Risk of injury should qualication be insucient!
Improper handling can result in considerable injury and damage to equipment. The activities described in these operating instructions may only be carried out by skilled personnel who have the qualications described below.
Skilled personnel
Skilled personnel are understood to be personnel who, based on their technical training, knowledge of measurement and control technology and on their experience and knowledge of country-specic regulations, current standards and directives, are capable of carrying out the work described and independently recognising potential hazards.
Special operating conditions require further appropriate knowledge, e.g. of aggressive media.
2.3 Special hazards
WARNING!
For hazardous media such as oxygen, acetylene, ammable or toxic gases or liquids, and refrigeration plants, compressors, etc., in addition to all standard regulations, the appropriate existing codes or regulations must also be followed.
WARNING!
Residual media in dismounted digital pressure gauges can result in a risk to persons, the environment and equipment. Take sucient precautionary measures.
GB
11250313.03 09/2012 GB/D/F/E
7WIKA operating instructions digital pressure gauge, model DG-10
2. Safety
2.4 Labelling / safety marks
Product label
GB
Measuring range
Power supply P# Product no.
If the serial number becomes illegible due to mechanical damage or overpainting, traceability will no longer be possible.
Explanation of symbols
Before mounting and commissioning the instrument, ensure you read the operating instructions!
CE, Communauté Européenne
Instruments bearing this mark comply with the relevant European directives.
S# Serial no.
8 WIKA operating instructions digital pressure gauge, model DG-10
11250313.03 09/2012 GB/D/F/E
3. Specications
3. Specications
3.1 Measuring ranges
Relative pressure
bar Measuring range 0 ... 2 0 ... 5 0 ... 10 0 ... 20 0 ... 50 0 ... 100
Overpressure limit 5 10 20 40 100 200 Burst pressure 6 12 25 50 120 800
Measuring range 0 ... 160 0 ... 250 0 ... 400 0 ... 600
Overpressure limit 320 500 800 1,200 Burst pressure 1,000 1,200 1,700 2,400
psi Measuring range 0 ... 30 0 ... 60 0 ... 145 0 ... 300 0 ... 600 0 ... 1,450
Overpressure limit 70 145 290 580 1,450 2,900 Burst pressure 85 170 360 725 1,740 11,600
Measuring range 0 ... 2,000 0 ... 3,000 0 ... 5,000 0 ... 7,500 0 ... 10,000
Overpressure limit 4,640 7,250 11,600 17,400 21,750 Burst pressure 14,500 17,400 24,650 34,800 43,500
1) only possible with DG-10-E (DG-10-S can only display up to 9999 psi)
1)
Vacuum and +/- measuring ranges
bar Measuring range -1 ... +2 -1 ... +5 -1 ... +10
Overpressure limit 5 10 20 Burst pressure 6 12 25
psi Measuring range -30 inHg ... +29 psi -30 inHg ... +72 psi -30 inHg ... +145 psi
Overpressure limit 70 145 290 Burst pressure 85 170 360
GB
11250313.03 09/2012 GB/D/F/E
9WIKA operating instructions digital pressure gauge, model DG-10
3. Specications
3.2 Digital indicator
See chapter 6.3 "Description of the digital indicator"
3.3 Software functions
GB
See chapter 6.4 "Keys and functions"
3.4 Approvals, directives and certicates
CE conformity
Pressure equipment directive 97/23/EC, PS > 200 bar; module A, pressure accessory
EMC directive 2004/108/EC, EN 61326 emission (group 1, class B) and immunity (industrial applica­tion)
3.5 Voltage supply
see chapter 6.2 "Voltage supply"
3.6 Reference conditions
Temperature
0 ... 60 °C
Atmospheric pressure
860 ... 1,060 mbar
Humidity
< 90 % rel., non-condensing
Nominal position
Calibrated in vertical mounting position with pressure connection facing downwards.
Power supply
2 x 1.5 V AA cell
10 WIKA operating instructions digital pressure gauge, model DG-10
11250313.03 09/2012 GB/D/F/E
3. Specications
3.6 Accuracy
Accuracy at reference conditions
≤ ±0.5 % of span ±1 digit
Including non-linearity, hysteresis, zero oset and end value deviation (corresponds to measured error per IEC 61298-2).
Zero error for the zero signal
≤ 0.1 % of span (power-up reset)
Adjustability of zero point
≤ 20 % of span (via tare function with model DG-10-E)
Temperature error at 0 ... 60 °C
Mean temperature coecient of zero point ≤ 0.15 % of span/10 K
Mean temperature coecient of span ≤ 0.15 % of span/10 K
Long-term stability
≤ 0.2 % of span/year
GB
11250313.03 09/2012 GB/D/F/E
11WIKA operating instructions digital pressure gauge, model DG-10
3. Specications
3.7 Operating conditions
Ingress protection (per IEC 60529)
IP 65
GB
Temperatures
Medium:
- Measuring range < 100 bar: -30 ... +85 °C
- Measuring range ≥ 100 bar: -30 ... +100 °C
Ambient: -10 ... +60 °C
Storage: -20 ... +70 °C
3.8 Materials
Wetted parts
Process connection: Stainless steel 1.4571
Sensor element ≤ 50 bar: Ceramic Al2O3 96 %
NBR (option: EPDM)
Sensor element > 100 bar: XM-13 (stainless steel 1.4534)
Non-wetted parts
Case: Stainless steel 1.4301
Front foil and membrane: Polyester
For special model numbers, e.g. DG-10000, please note the specications stated on the delivery note. For further specications see WIKA data sheet PE 81.66 and the order documentation.
12 WIKA operating instructions digital pressure gauge, model DG-10
11250313.03 09/2012 GB/D/F/E
4. Design and function / 5. Transport, packaging and storage
4. Design and function
4.1 Description
The prevailing pressure is measured at the sensor element through the deformation of a diaphragm. By supplying power, this deformation of the diaphragm is converted into an electrical signal. This signal is displayed via a digital indicator.
4.2 Scope of delivery
Cross-check scope of delivery with delivery note.
5. Transport, packaging and storage
5.1 Transport
Check the digital pressure gauge for any damage that may have been caused by transport. Obvious damage must be reported immediately.
5.2 Packaging
Do not remove packaging until just before mounting. Keep the packaging as it will provide optimum protection during transport (e.g. change in installation site, sending for repair).
5.3 Storage
Permissible conditions at the place of storage:
Storage temperature: -20 ... +70 °C
Humidity: < 90 % rel., non-condensing
GB
WARNING!
Before storing the digital pressure gauge (following operation), remove any residual media. This is of particular importance if the medium is hazardous to health, e.g. caustic, toxic, carcinogenic, radioactive, etc..
11250313.03 09/2012 GB/D/F/E
13WIKA operating instructions digital pressure gauge, model DG-10
6. Commissioning, operation
6. Commissioning, operation
CAUTION!
GB
6.1 Mechanical mounting
The sealing faces at the instrument have to be undamaged and clean.
When screwing the instrument in, the force required to do this must not be applied through the case, but only through the spanner ats provided for this purpose and using a suitable tool.
The correct torque depends on the dimensions of the process connection and the gasket used (form/material).
Do not overwind the process connection, do not exceed the permissible torques.
When screwing in, do not cross the threads.
For information on tapped holes and welding sockets, see Technical information IN 00.14 at www.wika.com.
Prior to commissioning, the digital pressure gauge must be subjected to a visual inspection. Only use the digital pressure gauge if it is in perfect condition with respect to safety.
Required tool: Open-ended spanner (spanner width 27)
Spanner ats
14 WIKA operating instructions digital pressure gauge, model DG-10
11250313.03 09/2012 GB/D/F/E
6. Commissioning, operation
Sealing of the process connection
Parallel threads Tapered threads
per EN 837 per DIN 3852-E NPT, R and PT
GB
Correct sealing of the process connections with parallel threads at the sealing face must be made using suitable at gaskets, sealing rings or WIKA prole sealings.
For further information on sealings see WIKA data sheet AC 09.08 or under www.wika.com.
Rotatability of the case
The case of the model DG-10-E can be rotated through 300°, thus the display can be read from almost any position.
Do not turn the case forcibly past the stop point.
11250313.03 09/2012 GB/D/F/E
For sealing process connections with tapered threads, the sealing must be made in the threads using additional sealing material, e.g. PTFE tape (EN 837-2).
300°
15WIKA operating instructions digital pressure gauge, model DG-10
6. Commissioning, operation
6.2 Voltage supply
The power supply for the digital pressure gauge is provided via two 1.5 V AA cells. The operating time is approx. 4,000 hours, when using batteries with a capacity of 2,000 mAh.
GB
Battery status
The battery status is shown by a battery symbol in the display (see chapter 6.3 "Description of the digital indicator").
Change the batteries as follows, as soon as the battery symbol shows no bars and is blinking.
Change batteries
Take the cover o.
16 WIKA operating instructions digital pressure gauge, model DG-10
Remove the battery compart­ment with the help of the tab and change the batteries.
Put the instrument back together in the reverse order.
11250313.03 09/2012 GB/D/F/E
6. Commissioning, operation
6.3 Description of the digital indicator
Model DG-10-S Model DG-10-E
Type of indication 7-Segment LCD 7-segment LCD
Digits 4-digit 4 ½-digit
Character size 11 mm 11 mm and 7 mm
Indication range -1999 ... 9999 -1999 ... 19999
Update 200 ms 200 ms
Backlighting no yes
Bargraph with drag pointer function yes yes
Rotatability no 300°
Model DG-10-S Model DG-10-E
14-segment LCD (2. Display)
GB
Max. value Min. value
Main display
Battery status
11250313.03 09/2012 GB/D/F/E
Bargraph display
Full scale
Unit
Max. value Min. value
Main display
Battery status
Bargraph display
Special functions Tare activated
2. Display
Full scale
Unit
17WIKA operating instructions digital pressure gauge, model DG-10
6. Commissioning, operation
Backlighting (model DG-10-E)
The model DG-10-E features backlighting so that the display can be easily read, even under poor lighting conditions.
GB
After pressing any key, the display will light up for 7 seconds.
The backlighting can be switched on and o via the menu item "LIGH", see chapter 6.4 "Menu navigation in the programming mode, model DG-10-E".
6.4 Keys and functions
Function Model DG-10-S Model DG-10-E
MIN/MAX memory yes yes Automatic power-o no 15, 30, 60, 120 minutes Tare function no yes Unit change bar, psi, MPa bar, psi, MPa Password protection no yes Reset to factory settings no yes
Bargraph display with drag pointer function
The additional integrated bargraph with drag-pointer function within the display indicates the trend of the current pressure directly, independently from the digital indicator. Using the drag-pointer function, the max. memory value is also displayed in the bargraph display in the form of a bar segment, as well as in the digital indicator. On resetting the MIN/MAX value, this bargraph is then updated to the current measured value.
18 WIKA operating instructions digital pressure gauge, model DG-10
11250313.03 09/2012 GB/D/F/E
6. Commissioning, operation
MIN/MAX memory
The MIN/MAX memory is reset to the current measured value with each measuring cycle.
Tare function "TARE" (model DG-10-E)
In this mode, the positive deviation of the measured value from the tared value (max. 20 % of the measuring range) is shown on the main display. The non-tared value is shown on the bargraph display, so that you can always read the current utilisation of the digital pressure gauge.
The following possibilities can be activated for the tare function:
Select the tare function via the "TARE" menu item. Use the arrow keys to adjust the value to be tared. The adjusted value to be tared will be stored in the memory as tare.
Load the digital pressure gauge to the pressure to be tared. The main display will show the current measured value. Via the menu, select the tare function, "TARE", and press the two arrow keys simultaneously. The current measured value will be stored as tare. The main and secondary display will be set to "0000".
The tare function can be reset in both variants by setting the tare value to "0000".
GB
11250313.03 09/2012 GB/D/F/E
19WIKA operating instructions digital pressure gauge, model DG-10
6. Commissioning, operation
Key function in the operating mode
Switches the digital pressure gauge on or o.
GB
Switches the instrument to the programming mode (pressing for longer than 3 seconds).
On pressing, the display indicates the max. value.
On pressing, the display indicates the min. value.
+ +
20 WIKA operating instructions digital pressure gauge, model DG-10
Resets the max. value to 0.
Resets the min. value to 0.
11250313.03 09/2012 GB/D/F/E
6. Commissioning, operation
Menu navigation in the programming mode, model DG-10-S
Operating mode
Software version
Display of the measuring range
Selection of the unit
"UNIT"
Saving the settings
"STOR"
< 3 seconds
MPa PSI BAR
YES
NO
GB
Factory setting "BAR"
Factory setting "NO"
11250313.03 09/2012 GB/D/F/E
21WIKA operating instructions digital pressure gauge, model DG-10
6. Commissioning, operation
Menu navigation in the programming mode, model DG-10-E
GB
Software version
Display of the measuring range
Password status
"P.STA"
"P.CHA" (next page)
< 3 seconds
if P.STA "OFF"
Operating mode
Password request
"PASS"
ON
OFF
Password wrong
▼ key changes the digit ▲ key sets the numerical value
Factory setting "0000"
Password correct
"ON" - password is requested.
"OFF" - password is not requested, "PASS" menu item is not shown in menu
Factory setting "OFF"
22 WIKA operating instructions digital pressure gauge, model DG-10
11250313.03 09/2012 GB/D/F/E
6. Commissioning, operation
Changing the password
"P.CHA"
Selection of the unit
"UNIT"
Tare function
"TARA"
Backlighting
"LIGH"
"A.OFF" (next page)
Key changes the digit
Key sets the numerical value
MPa PSI BAR
see point "Tare function" on page 19
ON
OFF
Factory setting "0000"
Factory setting "BAR"
Factory setting "0000"
Factory setting "OFF"
GB
11250313.03 09/2012 GB/D/F/E
23WIKA operating instructions digital pressure gauge, model DG-10
6. Commissioning, operation
Automatic power-o
GB
"A.OFF"
Reset to factory settings
"FAC"
Saving the settings
"STOR"
"P.STA"
OFF
15, 30, 60, 120 minutes
YES
NO
YES
NO
Operating mode
Factory setting "OFF"
Factory setting "NO"
Factory setting "NO"
24 WIKA operating instructions digital pressure gauge, model DG-10
11250313.03 09/2012 GB/D/F/E
7. Maintenance and cleaning
7. Maintenance and cleaning
7.1 Maintenance
The digital pressure gauge is maintenance-free. Repairs must only be carried out by the manufacturer.
7.2 Cleaning
CAUTION!
Before cleaning, correctly disconnect the digital pressure gauge from the pressure supply.
Clean the instrument with a moist cloth.
Wash or clean the dismounted instrument before returning it, in order to protect persons and the environment from exposure to residual media.
Residual media in dismounted instruments can result in a risk to persons, the environment and equipment. Take sucient precautionary measures.
Do not use any pointed or hard objects for cleaning.
For information on returning the instrument see chapter 9.2 "Return".
GB
11250313.03 09/2012 GB/D/F/E
25WIKA operating instructions digital pressure gauge, model DG-10
8. Faults
8. Faults
In the event of any faults, rst check whether the digital pressure gauge is mounted correctly, mechanically
GB
and electrically.
Faults Causes Measures
No display Batteries discharged
Batteries inserted the wrong way around
Display remains on 0, despite there being pressure
Constant display signal upon change in pressure
Signal span too small Signal span varies EMC interference sources in the environment
Signal span inaccurate Operating temperature too high/low Observe the permissible
Deviating zero point signal Medium or ambient temperature too high/low Observe the permissible
Instrument turned too far
Sensor wire broken Mechanical overload caused by overpressure Replace instrument
Mechanical overload caused by overpressure
Operating temperature too high/low
If complaint is unjustied, we will charge you the complaint processing fees.
CAUTION!
If faults cannot be eliminated by means of the measures listed above, shut down the digital pressure gauge immediately, and ensure that pressure and/or signal are no longer present, and secure the instrument from being put back into operation inadvertently. In this case, contact the manufacturer. If a return is needed, please follow the instructions given in chapter 9.2 "Return".
Change batteries
Insert the batteries with the polarity correct
Replace instrument
Replace instrument Remove sources of interference
Observe the permissible temperatures
temperatures
temperatures
26 WIKA operating instructions digital pressure gauge, model DG-10
11250313.03 09/2012 GB/D/F/E
9. Dismounting, return and disposal
9. Dismounting, return and disposal
WARNING!
Residual media in dismounted pressure transmitters can result in a risk to persons, the environment and equipment. Take sucient precautionary measures.
9.1 Dismounting
Only disconnect the digital pressure gauge once the system has been depressurised!
9.2 Return
WARNING! Strictly observe the following when shipping the digital pressure gauge:
All digital pressure gauges delivered to WIKA must be free from any kind of hazardous substances (acids, bases, solutions, etc.).
When returning the instrument, use the original packaging or a suitable transport package.
Information on returns can be found under the heading "Service" on our local website.
9.3 Disposal
Incorrect disposal can put the environment at risk. Dispose of instrument components and packaging materials in an environmentally compatible way and in accordance with the country-specic waste disposal regulations.
GB
11250313.03 09/2012 GB/D/F/E
27WIKA operating instructions digital pressure gauge, model DG-10
10. Accessories
10. Accessories
GB
Description Order no.
Rubber protection cap (black) 11262010
Minimess connector
Maximum pressure strength 630 bar
Sealing for process connection per DIN 3852-E
Material NBR
Thread size G ¼ A 1537857
9072314
28 WIKA operating instructions digital pressure gauge, model DG-10
11250313.03 09/2012 GB/D/F/E
Inhalt
Inhalt
1. Allgemeines 30
2. Sicherheit 32
3. Technische Daten 35
4. Aufbau und Funktion 39
5. Transport, Verpackung und Lagerung 39
6. Inbetriebnahme, Betrieb 40
7. Wartung und Reinigung 51
8. Störungen 52
9. Demontage, Rücksendung und Entsorgung 53
10. Zubehör 54
Anlage 1: EG-Konformitätserklärung Typ DG-10 55
Konformitätserklärungen nden Sie online unter www.wika.de.
11250313.03 09/2012 GB/D/F/E
D
29WIKA Betriebsanleitung Digitalmanometer, Typ DG-10
1. Allgemeines
1. Allgemeines
Das in der Betriebsanleitung beschriebene Digitalmanometer wird nach dem aktuellen Stand der Technik konstruiert und gefertigt. Alle Komponenten unterliegen während der Fertigung strengen Qualitäts- und Umweltkriterien. Unsere Managementsysteme sind nach ISO 9001 und ISO 14001 zertiziert.
D
Diese Betriebsanleitung gibt wichtige Hinweise zum Umgang mit dem Gerät. Voraussetzung für sicheres Arbeiten ist die Einhaltung aller angegebenen Sicherheitshinweise und Handlungsanweisungen.
Die für den Einsatzbereich des Gerätes geltenden örtlichen Unfallverhütungsvorschriften und allgemeinen Sicherheitsbestimmungen einhalten.
Die Betriebsanleitung ist Produktbestandteil und muss in unmittelbarer Nähe des Gerätes für das Fachpersonal jederzeit zugänglich aufbewahrt werden.
Das Fachpersonal muss die Betriebsanleitung vor Beginn aller Arbeiten sorgfältig durchgelesen und verstanden haben.
Die Haftung des Herstellers erlischt bei Schäden durch bestimmungswidrige Verwendung, Nichtbeachten dieser Betriebsanleitung, Einsatz ungenügend qualizierten Fachpersonals sowie eigenmächtiger Veränderung am Gerät.
Es gelten die allgemeinen Geschäftsbedingungen in den Verkaufsunterlagen.
Technische Änderungen vorbehalten.
Weitere Informationen:
- Internet-Adresse: www.wika.de / www.wika.com
- zugehöriges Datenblatt: PE 81.66
- Anwendungsberater:
Tel.: (+49) 9372/132-8976 Fax: (+49) 9372/132-8008976 E-Mail: support-tronic@wika.de
30 WIKA Betriebsanleitung Digitalmanometer, Typ DG-10
11250313.03 09/2012 GB/D/F/E