19WIKA operating instructions, pressure sensor, models D-20-9, D-21-9
EN
2059064.05 EN/DE/FR/ES 01/2019
9. Specications
Specications
Measuring ranges [bar] 0.25 0.4 0.6 1 1.6 2.5 4 6 10 16
25 40 60 100 160 250 400 600 1,000 (only for model
D-20-9)
Overload safety Measuring ranges ≤ 1.6 bar: 5-fold
Measuring ranges 2.5 ... 16 bar: 4-fold (measuring range 10 bar: 3-fold)
Measuring ranges 25 ... 600 bar: 2-fold
Measuring range 1,000 bar: 1.5-fold
Material Wetted parts
Model D-20-9: Stainless steel
Model D-21-9: Stainless steel (option: Hastelloy); O-ring: NBR (option: FPM/FKM or EPDM)
Case: Stainless steel
For other materials, see WIKA diaphragm seals product range
Internaltransmissionuid Synthetic oil
Halocarbon oil for oxygen versions (option)
Listed by FDA for food industry (option)
No transmission uid for model D-20-9 with measuring range > 25 bar
Power supply U+ DC 10 ... 30 V
Output signal CANopen protocol in accordance with CiA DS-301 V. 4.02, device prole DS-404 V. 1.2
Power consumption < 0.5 W
< 0.7 W with galvanic isolation (option)
Communication services LSS (CiA DSP 305, version 1.1.1) services
Conguration of the instrument address and baud rate
Sync/Async, Node/Lifeguarding, Heartbeat
Individually programmable lter in order to suppress, for example, specic resonant frequencies
Response time (10 ... 90 %) 1.5 ms (baud rate ≥ 125 K)
Internal measuring rate 1.000 Hz (adjustable up to approx. 4 Hz)
Insulation voltage DC 500 V
9.Specications