Multi-functional precision thermometer,
model CTR3000
Calibration technology
WIKA data sheet CT 60.15
Description
Application
The model CTR3000 precision thermometer provides a
complete measurement and control interface for users
wishing to make high-accuracy temperature measurements
or calibrate thermometers. It supports a wide range of
thermometer types including 25 Ω SPRTs, 100 Ω PRTs,
thermistors and thermocouples.
The CTR3000 is a high-accuracy instrument designed for
laboratory and industrial temperature measurement and
calibration applications.
Functionality
The instrument will operate with all 3- and 4-wire (S)PRTs
(25 Ω, 100 Ω) platinum resistance thermometers as well as
most standard international thermocouple types and NTC
thermistors. The following temperature measurement units
are selectable: °C, °F, K. Base measuring units mV and Ω
are also displayed. The temperature values will be calculated
through common conversion of the base measurement.
∙ 01/2017
Due to the wide range of this instrument it makes
individual instruments needless and makes the calibration
cost-eective.
Features included:
■
Dual capability for both thermocouple and resistance
thermometer measurements
■
Input channels can be expanded up to 44
■
Large graphic touchscreen for temperature measurement
values as well as conguration settings and statistical
results
■
Logger and log-data transfer to USB stick or
communication interface
■
Scan function with a live screen and graph
■
Communication interfaces available for automated
monitoring and calibration applications
Page 1 of 9WIKA data sheet CT 60.15
Data sheets showing similar products:
Precision thermometer; model CTR5000; see data sheet CT 60.20
Specications
Model CTR3000
Multi-functional precision thermometer
Input
Input channels4
Channels 1 + 2Resistance thermometers with 5-pin DIN connector
Channels 3 + 4Thermocouple with standard miniature 2-pin thermocouple plug
■
Scanner box
Input connections5-pin DIN plug or bare wires (resistance thermometer or thermistor)
Data entry format
Measuring ranges
1)
PRT/SPRTMeasuring range 0 ... 500 Ω
ThermocoupleMeasuring range ±100 mV
Thermistor0 ... 500 kΩ
1) Depending on sensor type
up to 4 modules
■
max. 44 channels (in total)
■
each module has 10 channels
Standard miniature 2-pin thermocouple plug or bare wires (thermocouple)
■
ITS-90 and CvD for calibrated resistance thermometers; or EN 60751 standard conversion for
uncalibrated resistance thermometers
■
TC polynomial for calibrated thermocouples; or EN 60584 standard conversion for uncalibrated
thermocouple
■
Steinhart and Hart for NTC thermistors
-200 … +962 °C (-328 ... +1,764 °F)
3- and 4-wire measurement
-210 … +1,820 °C (-346 ... +3,308 °F)
Type B, E, J, K, N, R, S, T in accordance with EN 60584
Accuracies
2)
Resistance thermometer
Base measurement0.002 Ω
Temperature accuracy4-wire
3-wire
±0.005 K
±0.03 K
Temperature conversionsStandard EN 60751, CvD, ITS-90
Sensor currents1 mA, 2 mA and √2
Keep warm currentsR
< 50 Ω
0
R0 ≥ 50 Ω
0 ... 125 Ω
0 ... 500 Ω
2 mA
1 mA
Measurement time3 seconds update rate
Thermocouple
Base measurement
3)
±% of reading + µV
±0.004 % + 2 µV
Temperature accuracyType B
Type E
Type J
Type K
Type N
Type R
Type S
Type T
±0.09 °C + ±0.025 % of reading
±0.05 °C + ±0.031 % of reading
±0.07 °C + ±0.030 % of reading
±0.09 °C + ±0.035 % of reading
±0.08 °C + ±0.035 % of reading
±0.27 °C + ±0.020 % of reading
±0.27 °C + ±0.020 % of reading
±0.09 °C + ±0.025 % of reading
Temperature conversionsStandard EN 60584, polynomial
Measurement time3 seconds update rate
Cold junction compensationInternal, external or channel
Accuracy internal cold junction compensation ±0.15 K
2) The accuracy in K denes the deviation between the measured value and the reference value. (Only valid for indicating instruments.)
3) In a range of -20 mV ... +100 mV
Page 2 of 9WIKA data sheet CT 60.15 ∙ 01/2017
Accuracies
Thermistor
Accuracy0 ... 400 Ω
Temperature conversionsSteinhart-Hart, Polynomial
Sensor currents0 ... 450 Ω
Measurement time3 seconds update rate
2) The accuracy in K denes the deviation between the measured value and the reference value. (Only valid for indicating instruments.)
3) In a range of -20 mV ... +100 mV
2)
±0.006 Ω
400 Ω ... 50 kΩ
50 ... 500 kΩ
400 Ω ... 45 kΩ
40 ... 500 kΩ
±0.01 % of reading
±0.02 % of reading
1 mA
10 μA
3 μA
Digital indicator
Display
ScreenColour TFT display including projective capacitive touchscreen with a resolution of 800 x 480 pixels
Resolution0.0001 K / 0.00001 Ω / 0.00001 mV
Display units°C, °F, K, mV and Ω
Functions
Real-time clockIntegrated clock with date
Voltage supply
Power supplyAC 100 ... 240 V, 47 ... 63 Hz; universal input on rear panel
Permissible ambient conditions
Operating temperature0 ... 50 °C (32 ... 122 °F)
Maximum achievable accuracy within 17 ... 23 °C (63 ... 73 °F)
Relative humidity0 … 70 % r. h. (non-condensing)
Storage temperature-20 ... +50 °C (-4 ... +122 °F)
Communication
InterfacesStandard: USB host, USB device and Ethernet
Optional: RS-232
Case
Dimensions (W x H x D)314 x 176 x 322 mm (12.4 x 6.9 x 12.7 in)
Weight6 kg (13.2 lbs)
Approvals
LogoDescriptionCountry
EU declaration of conformity
■
EMC directive
■
Low voltage directive
European Union
Certicates
Certicate
Calibration
Recommended recalibration interval1 year (dependent on conditions of use)
4) System calibration with a temperature probe and/or electrical calibration of the CTR3000 itself
Approvals and certicates, see website
WIKA data sheet CT 60.15 ∙ 01/2017 Page 3 of 9
4)
Standard: 3.1 calibration certicate per DIN EN 10204
Option: DKD/DAkkS calibration certicate
Touchscreen and intuitive operator interface
Switching on the instrument, the main screen appears. From
here the user can make several settings and can see in this
case the measurement in °C of a 4-wire Pt25 connected to
channel 1.
On the right side the user can select the menus to select
inputs or settings.
Standard desktop/main screen
21
20
19
18
17
16
15
“In” the main screen are function buttons located with which
the user can select settings really quickly. This is like a
shortcut to the menu or an immediate setting.
A click on these guides to a menu which opens on the right
side or causes a change on the display.
1
2
3
4
5
6
7
8
Home application
1
General settings
2
Probe settings
3
Scan settings
4
Logger settings
5
Remote settings
6
Info display
7
Service settings
8
Unit; shortcut
9
Plus decimal place
10
Clear the peak values (min, max measured since starting the
11
instrument)
10121314119
Selected probe (standard or custom); shortcut
12
Freeze the display; function key
13
Root 2 for sensor current PRT; function key
14
Current displaying of average, stability and number of
15
measurements
Peak displaying
16
Minus decimal place
17
Measured value in the base unit according to probe, e.g. Ω for
18
Pt100 and mV for TC
Current measured value
19
Selected channel; shortcut
20
Current application name
21
Page 4 of 9WIKA data sheet CT 60.15 ∙ 01/2017
Simple instrument congurations
General settings of the instrument
Probe settings
If selecting the menu on the right side, the settings appear on
the left side. Selecting e.g. language all available languages
will be displayed on the right section and can easily be
chosen.
In the menu setting all things concerning the instrument can
be handled.
In this menu the probe settings can be selected and the
reference thermometers can be stored under a unique name.
Scan settings
Two views can be selected: scan and graph
Due to the wide range of this instrument it makes individual instruments needless and makes the calibration cost-eective.
Logger and scan function with a live screen and graph makes calibration life easy.
Scan viewGraphical scan view
In this menu the user can dene a scan by selecting the
channels and the hold time. For activating the scan use the
start button.
WIKA data sheet CT 60.15 ∙ 01/2017 Page 5 of 9
Dimensions in mm (in)
Front viewSide view (left)
Rear view
Page 6 of 9WIKA data sheet CT 60.15 ∙ 01/2017
Resistance thermometer connection (5-pin DIN connector)
Channel 1 and 2 (PRT1, PRT2)
View towards front panel connector
2-wire PRT connection3-wire PRT connection
ShieldShield
4-wire PRT connection
Shield
Options
Viewed from top panel
Shield
WIKA data sheet CT 60.15 ∙ 01/2017 Page 7 of 9
With DIN plug or SMART plug
With ASL's SMART connector on the probes, storing the data
is needed only once - in the connector! The calibration data
stays with the probe - permanently. It can even be used on
another instrument without any further action.
The SMART connector saves time and reduces error.
If there are existing calibrated or uncalibrated probes, no
problem, CTR3000 automatically registers if a probe is
SMART or normal.
Thermocouple connection (miniature connector), channel 3 and 4 (TC3, TC4)
Miniature
thermocouple plug
Further details
Thermocouple
connection
We are expanding our product range of precision
thermometers to a versatile thermometer for the industrial
market with the model CTR3000 multi-functional
precision thermometer. The ability to measure resistance
thermometers, thermocouples and thermistors up to 44
pieces at one time, makes the instrument versatile.
CTR5000
CTH7000
CTH6200
Resistance thermometer measurement
The CTR3000 is new in its class. The instrument closes
the gap between the hand-held series CTH6x00 which can
handle thermocouples and the desktop instrument like model
CTR5000 which can only handle resistance thermometers.
CTR3000
CTH6500
CTH6300
TC and PRT measurement
It is a precision instrument, designed for use in a laboratory
or light industrial environment. The instrument can be
extended by using scanner boxes to gain additional
channels.
Page 8 of 9WIKA data sheet CT 60.15 ∙ 01/2017
The instrument model CTR3000 is compatible with the
existing model CTS5000 scanner box for resistance
thermometers. In addition, the user interface is easy to
handle like other WIKA calibration technology products.
Scope of delivery
■
Model CTR3000 multi-functional precision thermometer
incl. power cord
■
3.1 calibration certicate per DIN EN 10204 (only system
calibration)
Option
■
DKD/DAkkS calibration certicate (only system
calibration)
Accessories
Temperature probes model CTP5000
■
Immersion probe
■
Customer-specic probes are available on request
Thermocouple model CTP9000
■
Immersion probe type S
■
With or without cold junction
■
Customer-specic probes are available on request
Multiplexer
■
10-channel multiplexer for resistance thermometers and
thermocouples (maximum of 4 multiplexers per CTR3000)
Case
■
Transport case, robust
Interface
■
Interface card RS-232
Ordering information
CTR3000 / Interface / Number of multiplexers / Number of resistance thermometers / Number of thermocouples / Transport
case / Additional order information
The specications given in this document represent the state of engineering at the time of publishing.
We reserve the right to make modications to the specications and materials.