WIKA CTR2000 Specifications

Precision thermometer Model CTR2000
Applications
Precision thermometer for very accurate temperature measurements in a range of -200 ... +962 °C
Self-contained, complete system, also suitable for on-site measurements/calibrations
Calibration technology
WIKA data sheet CT 60.10
Special features
Temperature range -200 ... +962 °C
Accuracy: 0.01 °C
2 channels as standard with optional 8 channels
4-wire measurement, optional 3-wire
SMART probe review and editor
Description
The model CTR2000 precision thermometer comprises two measurement versions: One version accepts only 4-wire PRTs, the other version accepts both 3- and 4-wire PRTs. The high-performance 2- or 8-channel, 3- and 4-wire precision digital thermometers is suitable for use with calibrated and uncalibrated Pt100 probes. It is characterised by its extended features for high usability and low life costs.
Using calibrated probes with the CTR2000 thermometer series choose between storing calibration data into memory in the instrument or into the probe’s proprietary SMART connector. Calibration data stays permanently with the probe in this connector, which the CTR2000 series instantly recognises, ensuring best measurement accuracy.
Precision thermometer, model CTR2000
Using a built-in calibration routine, the CTR2000 instrument range can be recalibrated using a calibrated, traceable reference resistor. This feature is password protected.
Other features have been included for CTR2000 range when using SMART probes, like the temperature watchdog and the calibration status monitor. The temperature watchdog continuously monitors the temperature of SMART probes and, if any are used outside
their specied working range, the probe history record is
updated.
With this way, it can be seen at a glance if the probes have ever been used outside their calibrated range, as this may
aect their calibration validity. The calibration status monitor
alerts with an on-screen message when a SMART probe is due for recalibration.
Data sheets showing similar products: Precision thermometer; model CTR5000; see data sheet CT 60.20 Reference thermometer; model CTP5000; see data sheet CT 61.20
Page 1 of 6WIKA data sheet CT 60.10 ∙ 07/2014
Specications
Model CTR2000
Precision thermometer
Probe types Industrial platinum resistance thermometers (PRTs) and standard platinum resistance ther-
mometers (SPRTs) with Ro = 25 Ω and 100 Ω up to an alpha of 0.00392
Measuring inputs 2 or 8
Data entry format ITS 90 and CVD for calibrated probes; or EN 60751 for uncalibrated probes
Measuring ranges
Probe current DC 1 mA switched polarity
Temperature range -200 ... +962 °C, depending on thermometer probe
Accuracy
1) The accuracy in K denes the deviation between the measured value and the reference value. (Only valid for indicating instruments.)
Digital indicator
Display
Screen large graphic VFD display screen
Resolution 0.001 °C
1)
0.01 K (4-wire)
0.03 K (3-wire, do not include uncertainties due to variations in sensor cables)
Functions
Real-time clock integrated clock with date
Voltage supply
Power supply AC 90 ... 264 V, 47 ... 63 Hz; universal rear input on rear panel
Power consumption max. 30 VA
Permissible ambient conditions
Operating temperature 15 ... 25 °C
Storage temperature -20 ... +50 °C
Communication
Interface RS-232
Case
Dimensions 168 x 108 x 215 mm (W x H x D)
Weight 1 kg
CE conformity, certicates
CE conformity
EMC directive 2004/108/EC, EN 61326 emission (group 1, class B) and interference immunity (portable test
and measuring equipment)
Certicates
Calibration
Recommended calibration interval 1 year (depending on the conditions of usage)
2) Only system calibration
2)
Standard: 3.1 calibration certicate per DIN EN 10204 Option: DKD/DAkkS calibration certicate
Approvals and certicates, see website
Page 2 of 6 WIKA data sheet CT 60.10 ∙ 07/2014