Temperature multi-function calibrator
Model CTM9100-150
for further approvals see
page 3
Applications
■
Testing and calibration of all types of temperature
measuring instruments
■
Reference instrument for works laboratories for the
calibration of thermometers
■
Also suitable for on-site calibration
Special features
■
Multi-function instrument with four controller parameter
sets
■
Calibration with an external reference
■
Low weight and compact design
■
Simple operation
Temperature multi-function calibrator
model CTM9100-150
Calibration
WIKA data sheet CT 41.40
Description
Versatile in application
Nowadays, fast and simple testing of thermometers is a
“must” when it comes to the operational safety of machines
and plants. The portable calibrators of the CTx9100 family
are particularly suited for on-site calibrations and extremely
user-friendly. Due to their compact design and their low
weight, the instruments can be taken and used almost
anywhere.
Using a dry-well calibrator or a micro calibration bath to
calibrate either surface thermometers or non-contact
thermometers does not reect the application and can result
in false values. In these cases, the model CTM9100-150
temperature multi-function calibrator should be used.
With this temperature multi-function calibrator, in the
temperature range from -20 ... +150 °C [-4 ... +302 °F], you
can cover not only the common functions, but also, with
special inserts, this can be used as a surface temperature
calibrator and an infrared black body. Like having four
instruments in one!
WIKA data sheet CT 41.40
∙ 08/2018
Easy to use
The temperature multi-function calibrator combines four
application possibilities in one instrument. The simple
instrument design enables fast and simple switching,
back and forth, between individual applications. Changing
between the four possibilities can be made very easily using
one of the four keys and the toggle switch on the front.
It is possible to calibrate nearly every thermometer with
the dierent inserts, even contact (TC, Pt, surface) or
non-contact (infrared) thermometers.
The calibration temperature, adjusted simply using two keys
on the controller, can be very quickly controlled. The actual
and set temperature can be displayed simultaneously on a
large 4-digit, high-contrast LC display. Thus reading errors
are virtually eliminated.
Page 1 of 7

Specications Model CTM9100-150
Display
Temperature range -20 ... +150 °C [-4 ... 302 °F]
-35 ... +165 °C [-31 ... 329 °F] Use as a micro calibration bath
Accuracy
Stability
1)
2)
Resolution 0.01 to 100 °C, then 0.1
Temperature control
Heating time depending upon usage and area of application
Cooling time depending upon usage and area of application
Stabilisation time
3)
Insert
Immersion depth 150 mm [5.91 in]
Insert dimensions Ø 60 x 170 mm [Ø 2.36 x 6.69 in]
Insert material Aluminium
Voltage supply
Power supply AC 100 ... 240 V, 50/60 Hz
Power consumption 400 VA
Fuse 6.3 A slow blow fuse
Power cord for Europe, 230 V
Communication
Interface RS-485
Case
Dimensions in [W x D x H] 215 x 305 x 425 mm [8.46 x 12.0 x 16.73 in]
Weight 12 kg [26.5 lbs]
1) Is dened as the measuring deviation between the measured value and the reference value.
2) Maximum temperature dierence at a stable temperature over 30 minutes.
3) Time before reaching a stable value.
±0.2 K
±0.3 K
±1 K
±1 K
±0.05 K
±0.05 K
±0.2 K
±0.2 K
depending upon usage and area of application
Use as a micro calibration bath
Use as a dry-well calibrator
Use as an infrared black body
Use as a surface temperature calibrator
Use as a micro calibration bath
Use as a dry-well calibrator
Use as an infrared black body
Use as a surface temperature calibrator
The measurement uncertainty is dened as the total measurement uncertainty (k = 2), which contains the following shares:
accuracy, measurement uncertainty of reference, stability and homogeneity.
WIKA data sheet CT 41.40 ∙ 08/2018 Page 2 of 7

Approvals
Logo Description Country
EU declaration of conformity
■
EMC directive
EN 61326, emission (group 1, class B) and interference immunity (industrial application)
■
Low voltage directive
EN 61010, safety requirements for electrical equipment for measurement, control and
laboratory use
■
RoHS directive
EAC
■
EMC directive
■
Low voltage directive
GOST
Metrology, measurement technology
KazInMetr
Metrology, measurement technology
- MTSCHS
Permission for commissioning
BelGIM
Metrology, measurement technology
European Union
Eurasian Economic
Community
Russia
Kazakhstan
Kazakhstan
Belarus
Certicates
Certicate
Calibration Standard: 3.1 calibration certicate per DIN EN 10204
Option: DKD/DAkkS calibration certicate
Recommended recalibration interval 1 year (dependent on conditions of use)
Approvals and certicates, see website
WIKA data sheet CT 41.40 ∙ 08/2018 Page 3 of 7