WIKA CTH7000 Specifications

Hand-held thermometer Model CTH7000
Applications
Precision thermometer for very accurate temperature measurements in a range of -200 ... +962 °C
Self-contained, complete system also suitable for on-site measurements/calibrations
Calibration technology
WIKA data sheet CT 55.50
Special features
Temperature range: -200 ... +962 °C
Stability: < 0.005 °C per year
Dual inputs measuring platinum resistance thermometers
(PRTs) and thermistors single or dierential measurement
High long-term stability
Description
The model CTH7000 hand-held thermometer is a high performance 2-channel thermometer for Pt100 and thermistor probes. The hand-held thermometer CTH7000 is a step up in measurement accuracy with a battery power.
The CTH7000 can handle all needs, with accuracies and resolutions normally associated with a bench top thermometer. Two inputs give direct temperatures from Pt100 or thermistor probes or can display the temperature
dierence between them. Measurements can be logged
directly to memory or, use the USB port to control and data log with the PC.
The CTH7000 will display a statistical analysis of measurements, with average value, min and max values and standard deviation. Because the CTH7000 will display in ohms as well as temperature, it can even be used to calibrate
Hand-held thermometer model CTH7000
one probe against another. Most instruments require to enter
calibrated probe data into memory to optimise measurement accuracy, which can mean a lot of data entering if you change probes regularly.
With ASL's SMART connector on the probes, you only need
to store the data once - in the connector! The calibration data stays with the probe - permanently. The probe can even be used on another CTH7000 without any further action.
The SMART connector saves time and reduces error. If you
have existing calibrated or uncalibrated probes, no problem,
CTH7000 automatically registers if a probe is SMART or
normal.
Data sheets showing similar products: Hand-held thermometer; models CTH6500, CTH65I0; see data sheet CT 55.10 Reference thermometer; model CTP5000; see data sheet CT 61.20
Page 1 of 6WIKA data sheet CT 55.50 ∙ 04/2014
Specications
Model CTH7000
Hand-held thermometer
Probe types Pt100 and Pt25 resistance thermometers, NTC thermistors
Measuring inputs 2
Data entry format ITS 90 and CVD for calibrated probes; or EN 60751 for uncalibrated probes
Measuring ranges
Probe current DC 1 mA (Pt100); Auto-select 1 mA, 10 µA and 3 µA for thermistors
Temperature range -200 ... +962 °C, depending on thermometer probe
Accuracy
Resistance thermometers
NTC thermistors 0 ... 400 Ω
1) The accuracy in K denes the deviation between the measured value and the reference value. (Only valid for indicating instruments.)
1)
Digital indicator
Display
Screen Large 4 1/2-digit two-line LCD screen with backlighting
Resolution 0.001 °C
Functions
Memory approx. 8,000 values
Functions via key press Statistical analysis: Min/Max, average and standard deviation, Hold, Zero, one-shot measure-
Real-time clock integrated clock with date and year
Voltage supply
Power supply Nickel-Metal Hydride (Ni-MH) rechargeable battery
Battery life approx. 20 hours of operation
Permissible ambient conditions
Operating temperature 15 ... 25 °C
Storage temperature -20 ... +50 °C
Communication
Interface USB
Case
Dimensions 232 x 97 x 53 mm (L x D x W)
Weight 500 g
0.015 K
400 Ω ... 50 kΩ 50 ... 400 kΩ
ment, measurement log
Charging socket built-in low battery indicator
±0.006 Ω
±0.01 % of reading ±0.02 % of reading
CE conformity, certicates
CE conformity
EMC directive 2004/108/EC, EN 61326 emission (group 1, class B) and interference immunity (portable test
and measuring equipment)
Certicates
Calibration Standard: 3.1 calibration certicate per DIN EN 10204
Option: DKD/DAkkS calibration certicate
Recommended calibration interval 1 year (depending on the conditions of usage)
Approvals and certicates, see website
Page 2 of 6 WIKA data sheet CT 55.50 ∙ 04/2014
Loading...
+ 4 hidden pages