2
Before using the heater, please read the instructions carefully. In the future
it will benet by its failure-free operation for a long time.
Flow water heaters series POW 12, 15, 18, 21, 24 – LCD are intended for heating tap water.
They can supply hot water to several water outlets located in different rooms. These heaters
are equipped with heating coils which are directly washed by water. Such direct process of
heating prevents scale formation and ensures high efciency and speed of heating water. The
microprocessor system analyses the temperature of inlet and outlet water, the set temperature,
and water consumption of the user. Based on the collected data, it increases or decreases
the heating power in such a way that the water temperature at the outlet corresponded to
the temperature set by the user. Such control of the heater operation ensures the comfort of
use and energy saving. Additionally, the heater is equipped with air lock sensors which limit,
to the minimum, the possibility of damage of the heating elements due to air locking of the
water distribution system, as well as the system adjusting the temperature drop caused by
the drop of supply voltage.
Heaters can additionally heat water that was pre-heated, e.g. with the use of the solar system
which at the heater inlet cannot exceed 60OC.
• The device cannot be installed in rooms in which the temperature may
fall below 0OC and in which there is the risk of explosion.
• This equipment is not intended to be used by persons (including children) of lower physical, sensory or mental capability, unless they operate
it under supervision.
• Attention should be paid to children not playing with the equipment.
Installation instructions
The installation and start-up of the POW-LCD heater should be done by a person qualied in
accordance with the guidelines contained in the Manual. All installation works should be carried out with disconnected power and water supplies. The heater electrical installation should
be conducted in accordance with the binding regulations. The device should be permanently
connected to electrical wiring with ground terminal. The electrical wiring should be equipped
with residual current circuit breaker protecting against electric shock and with a switch ensuring the disconnection of the device from the power source, in which the distance between the
contacts should be not less than 3 mm.
1. To the place in which the heater is to be installed lead electrical wiring and water distribu-
tion system, using for that the mounting template.
2. Drill holes and mount expansion plugs.
3. Install the control valve with a lter on cold water supply (Fig. 3).
4. Unscrew the fastening screw which holds the housing of the heater located at the bottom
of it (Fig. 1), take off the cover and disconnect the ribbon cable by taking the plug out of
the socket marked “LCD” (Fig. 2).
5. Screw the heater to the wall with the use of fastening screws, having earlier run the ower
cable through the hole.