OPERATING MANUAL
English
Digital Hot Plate
WH200D-1K / WH200D-2K / WH200D-3K
Operating Manual
ISO 9001
Certificate Registration No. 01 100084841
Printed in China
Changes without prior notification reserved
Important: keep operating manual for future use
Congratulations!
You have made an excellent choice.
WIGGENS thanks for the trust you have placed in us.
This operating manual has been designed to help you gain an understanding of the
operation and possible applications of our instruments. For optimal utilization of all
functions, we recommend that you thoroughly study this manual prior to beginning
operation.
Declaration of conformity EN
We declare under our sole responsibility that this product corresponds to the
directives ……. and conforms to the following standards or normative documents:
EN ISO ……
The WIGGENS Quality Management System
Unpacking and Inspecting
Please unpack the device carefully. Inspect them for possible damage. In the case of
any damage a damage report should be requested immediately. These instructions must
be followed fully for us to guarantee our full support of your claim for protecting against
loss from concealed damage. The form required for filing such a claim will be provided by
the carrier.
2
WIGGENS WH200D-1K / WH200D-2K / WH200D-3K
Content
1. Intended Use ............................................................................................................... 4
8.3. Contact /Technical Service ................................................................................. 29
3
Operating Manual
1. Intended Use
The WH200D-1K / WH200D-2K / WH200D-3K Hot Plate is a heating plate with a
ceramic coated stainless steel top plate. It uses PID temperature control technology for
accurate and reliable results and is suitable for complicated temperature control
requirements. The LED screen can display both the set and actual temperature and the
value setting is easily done via a convenient on-touch control board. The Hot Plate
features a timer function for automatic heating of up to 100 hours and an alarm signal
and automatic stop function in case of over temperature situations. A PT100 temperature
sensor can be connected in order to provide direct and more precise control of the actual
temperature.
4
WIGGENS WH200D-1K / WH200D-2K / WH200D-3K
2. Operator Responsibility
Use
- For heating liquids
Range of use
- Laboratories
- Schools
- Pharmacies
This device is suitable for use in all areas except:
- Residential areas
- Areas that are connected directly to a low-voltage supply network that also supplies
residential areas.
The safety of the user cannot be guaranteed
-if the appliance is operated with accessories that are not supplied or recommended by
the manufacturer or if the appliance is operated improperly contrary to the
manufacturer’s specifications.
The products of WIGGENS ensure safe operation when installed, operated, and
maintained according to common safety regulations. This section explains the potential
dangers that may arise when operating the instrument and also specifies the most
important safety precautions to preclude these dangers as far as possible.
The operator is responsible for the qualification of the personnel operating the
instrument.
The personnel operating the instrument should be regularly instructed about the
dangers involved with their job activities as well as measures to avert these
dangers.
Make sure all persons tasked with operating, installing, and maintaining the
instrument have read and understand the safety information and operating
instructions.
When using hazardous materials or materials that could become hazardous, the
instrument may be operated only by persons who are absolutely familiar with
5
Operating Manual
At the end of its service life the instrument is to be disposed of in
accordance with the local regulations specified for the disposal of
electronic industry waste in an environmentally friendly manner.
The products described in the operating instructions conform to the
requirements of the following European guidelines:
Low voltage regulations with respect to legal harmonization of the
member countries concerning electric devices for use within certain
voltage limits.
EMC guideline with respect to legal harmonization of the member
countries concerning electromagnetic compatibility.
these materials and the instrument. These persons must be fully aware of
possible risks.
Only qualified personnel are authorized to perform configuration, installation,
maintenance and repairs of the instrument.
Routine operation can also be carried out by untrained personnel who should
however be instructed by trained personnel.
If you have any questions concerning the operation of your instrument or the information
in this manual, please contact us!
2.1 Disposal
2.2 CE Conformity
6
WIGGENS WH200D-1K / WH200D-2K / WH200D-3K
Model
WH200D-1K
WH200D-2K
WH200D-3K
Display Mode
LED
Indicating Accuracy
F.S ±1%
Temperature Stability
±0.2°C
Temperature Range
50~300°C with Surface Temperature Control
40~300°C with External Sensor Control
(Setting Resolution 1°C)
Temperature Sensor
Inner Sensor: Thermocouple K(CA)
External Sensor: PT 100 probe
Power Supply
220V AC, 50Hz
Allowable Voltage Range
(90~110% of the Power Supply)
Heater Capacity
Approx.680W
Approx.1000W
Approx. 1500W
Safety Device
Thermostat, Circuit Protection
Control Method
On / Off Control, PID control
Connection Method
RS-232
Proportional Band Width(P)
0.0~100.0%
Integral Time (I)
1~9959min
Differential Time (D)
1~9959min
Sampling Cycle
0.5 sec
Ambient Temperature
5~35°C
Weight
2.8 kg
5 kg
7 kg
Dimension (W×L in mm)
170×170
320×320
400×300
Basic Order Number
400110
400111
400112
2.3. Technical Specifications
All measurements have been carried out at the stated voltage, frequency, and an
ambient temperature of 25°C.
Technical changes without prior notification reserved.
7
Operating Manual
WIGGENS Order Numbers consist of the Basic Order Number (BON)
and the Order Number Addition (ONA) which explains different
characteristics of the product that can vary from country to country. Order
Numbers as stated on the product label and box label are stated as Full
Order Numbers (FON), consisting of the BON followed by the ONA. For a
full explanation of the ONA of your product, please ask your local
WIGGENS support or refer to the Order Number Guide in the WIGGENS
General Catalog.
8
WIGGENS WH200D-1K / WH200D-2K / WH200D-3K
Symbol
Additional term / Description
Warning signs
The danger is classified using a signal word. Read and follow these
important instructions for averting dangers.
Warning!
Describes a possibly highly dangerous situation. If these instructions
are not followed, serious injury and danger to life could result.
Caution!
Describes a possibly dangerous situation. If this is not avoided, slight
or minor injuries could result. A warning of possible property damage
may also be contained in the text.
Notice!
Describes a possibly harmful situation. If this is not avoided, the
product or anything in its surroundings can be damaged.
Note!
Draws attention to something special.
3. Safety Instructions
3.1. Explanation of Safety Notes
In addition to the safety warnings listed, warnings are posted throughout the operating
manual. These warnings are designated by an exclamation mark inside an equilateral
triangle. “Warning of a dangerous situation (Attention! Please follow the
documentation).”
Follow the safety recommendations to prevent damage to persons or property.
Further, the valid safety instructions for working places must be followed.
9
Operating Manual
Important!
Indicates usage tips and other useful information.
3.2. For your protection
Make sure you read and understand all instructions and safety precautions listed in
this manual before installing or operating your instrument.
Keep the operation instructions in a place where they can be accessed by everyone.
Make sure the product is checked for proper condition regularly (depending on the
conditions of use). Regularly check (at least every 2 months) the proper condition of
the mandatory, warning, prohibition and safety labels.
Connect the instrument to a power socket with earthing contact (PE-protective
earth)!
The power supply plug serves as a safe disconnecting device from the line and must
always be easily accessible.
Do not stay in the area below the instrument.
Never operate damaged equipment.
Never operate instruments with damaged mains power cables.
Observe all warning labels.
Never remove warning labels.
Be aware of tripping! Never route the connection cable in highly frequented areas!
Be aware of possible cable damage! Keep the connection cable away from the
heating zone!
Repairs are to be carried out only by qualified service personnel
Always turn off the instrument and disconnect the mains cable from the power
source before performing any service or maintenance procedures, or before moving
the instrument.
This is not an explosion proof instrument. Do not use with any
highly flammable or explosive materials.
Never operate the hot plate in wet areas!