NOTE
Every effort has been made to ensure that the information contained in
this document was complete and accurate at the time of publishing.
Nevertheless, the authors retain the right to modify the information. This
customer document describes all the hardware units and functions
known at the present time. Descriptions may be included for units which
are not present at the customer site. The exact scope of delivery is described in the respective purchase contract.
Conformity
Information
For more information regarding CE marking and Declaration of Conformity (DoC), please contact your local Wieland Electric customer service
organization.
Technical support
Information concerning the product is available from the following
websites:
Figure 5.94 Tools > User Account ............................................................................................................ 106
8 Wieland Electric GmbH | BA001047 (Rev. A) | 06/2018
1 About this manual
DANGER
WARNING
ATTENTION
NOTE
1 About this manual
Please read this section carefully before you use this manual and the wienet Switch from Wieland. Here
you will find all the information required for commissioning and operation.
1.1 Target groups and qualification of personnel
Commissioning and installation of components for such types of installations must be considered.
Therefore, the system manual is targeted at the following:
Those who can verify that they have the corresponding training and already have corresponding
basic knowledge
System integrators
Electricians
1.2 Structure of the manual
As a guidance the overall table of contents is available in the manual at the beginning.
1.3 Presentation of safety-relevant information
Information that warns of personal injury or property damage are emphasized by safety instructions. Please
read this information carefully.
This operating manual uses various safety notices that are assigned according to the severity of a potential
hazard:
Danger!
Immediate or likely danger. Personal injury or death is possible.
Warning!
Possible danger. Not heeding this warning can lead to minor injuries.
Attention!
Damages to property is likely if these warnings are not heeded.
NOTE:
Supplementary information and useful tips, indirectly related to the safety of personnel or property.
"Danger" or "Warning" are strictly used for cases which present a risk to life or limb. Damage to property
only falls into these categories if there is also a risk of personal injury that corresponds to these levels.
Wieland Electric GmbH | BA001047 (Rev. A) | 06/2018 9
1 About this manual
ATTENTION
WARNING
Please, observe the following instructions:
Attention!
The Switch must be used in compliance with all applicable international and national laws and in compliance with
any special restrictions regulating the utilization of the Switch in prescribed applications and environments.
To prevent possible injury to health and damage to appliances and to ensure that all the relevant provisions have
been complied with, use only the original accessories.
Unauthorised modifications or utilization of accessories that have not been approved may result in damage to the
Switch and in a breach of applicable regulations. Unauthorized modifications or utilization of accessories that have
not been approved may result in the termination of the validity of the guarantee.
The Switch can not be opened.
Disconnect power before making any configuration changes.
If DC voltage is supplied by an external circuit, a protection device on the Power supply input is recommended.
Warning!
Voltage must not be exceeded by 57 V DC max.at the power connector on the Switch.
Do not expose the Switch to extreme ambient conditions. Protect the Switch against dust, moisture and high tem-
perature.
The Switch should not be used at petrol stations of flammable and explosive materials. We remind the users of the
duty to observe the restrictions concerning the utilization of radio devices at petrol stations, in chemical plants, or in
the course of blasting works in which explosives are used.
Turn off the Switch when travelling by plane. Utilization of the Switch in a plane may endanger the operation of the
plane or interfere with the mobile telephone network, and may be unlawful. Failure to observe these instructions
may result in the suspension or cancellation of telephone services for the respective client, or, it may result in legal
sanctions; it may also result in both eventualities.
When using the Switch in the close proximity of personal medical devices, such as cardiac pacemakers or hearing
aids, you must proceed with heightened caution.
If the Switch is in the proximity of TV sets, radio receivers and personal computers, it may cause interference.
It is recommended that you should create an appropriate copy or backup of all the important settings that are stored
in the memory of the device.
10 Wieland Electric GmbH | BA001047 (Rev. A) | 06/2018
2 Product Disposal Instructions
2 Product Disposal Instructions
The WEEE (Waste Electrical and Electronic Equipment: 2012/19/EU) directive has been introduced to ensure that electrical/electronic products are recycled using the best available recovery techniques to minimize the impact on the environament. This product contains high quality materials and components which
can be recycled. At the end of its life this product MUST NOT be mixed with other commercial waste for
disposal. Check the terms and conditions of your supplier for disposal information.
Wieland Electric GmbH | BA001047 (Rev. A) | 06/2018 11
3 Product Overview
Type
Order no.
WIENET FS 8-PN-W
83.040.1510.0
WIENET FS 8-EI-W
83.040.1500.0
Type
Order no.
WIENET FS 16-PN-W
83.040.1511.0
WIENET FS 16-EI-W
83.040.1501.0
Specifications
Description
Interface
I/O-Port
WIENET FS 8-XX-W: 8 x 10/100BaseT(X)
WIENET FS 16-XX-W: 16 x 10/100BaseT(X)
Power
6-pin screw Terminal Block (including relay)
Physical
Enclosure
Metal Shell
Protection
Class
IP30
Installation
DIN-Rail and Wall-Mount
Dimensions
(W x H x D)
WIENET FS 8-XX-W: 43mm x 120mm x 84mm
(1.69in x 4.72in x 3.3in)
WIENET FS 16-XX-W: 74mm x 120mm x 84mm
(2.91in x 4.72in x 3.3in)
EN 55011/ 55022 Class A, EN 61000-6-4,
FCC Part 15 Subpart B Class A
EMS
EN 55024/ EN 61000-6-2
EN 61000-4-2 (ESD) Level 3
EN 61000-4-3 (RS) Level 3
EN 61000-4-4 (EFT) Level 3
EN 61000-4-5 (Surge) Level 3
EN 61000-4-6 (CS) Level 3
EN 61000-4-8 (Magnetic Field) Level 3
Shock
IEC 60068-2-27
Freefall
IEC 60068-2-32
Vibration
IEC 60068-2-6
Wieland Electric GmbH | BA001047 (Rev. A) | 06/2018 13
3 Product Overview
No.
Item
Description
1
System LED panel
See section "System LED Panel" for further details.
2
ETH port
Eight 10/100BaseT(X) ports.
Port numbers in black are designated for port based Quality of Service
(QoS) functionality.
3
LNK/ACT LED
Link activity LED.
4
Speed LED
Fast Ethernet:
Amber: 100M
Off: 10M
3.2 Hardware Views
3.2.1 Front View
The following view applies to to WIENET FS 8-PN-W, WIENET FS 8-EI-W.
Figure 3.1 Front View
14 Wieland Electric GmbH | BA001047 (Rev. A) | 06/2018
The following view applies to WIENET FS 16-PN-W, WIENET FS 16-EI-W.
No.
Item
Description
1
System LED panel
See section "System LED Panel" for further details.
2
ETH port
Sixteen 10/100BaseT(X) ports.
Port numbers in black are designated for port based Quality of Service
(QoS) functionality.
3
LNK/ACT LED
Link activity LED.
4
Speed LED
Fast Ethernet:
Amber: 100M
Off: 10M
3 Product Overview
Figure 3.2 Front View
Wieland Electric GmbH | BA001047 (Rev. A) | 06/2018 15
3 Product Overview
No.
LED
Name
LED Color
Description
1
PW1 LED
Solid green
Powered up.
Off
Powered down or not installed.
2
PW2 LED
Solid green
Powered up.
Off
Powered down or not installed.
3
P-Fail
Solid red
When PW1 or PW2 is disconnected.
Off
When PW1 and PW2 is connected.
4
Loop
Solid red
When loop detected.
Off
No loop detected.
No.
Item
Description
1
DIN-Rail mounting
plate
Mounting plate used for the installation to a standard DIN rail.
1
3.2.1.1 System LED Panel
Figure 3.3 System LED Panel
3.2.2 Rear View
The following view applies to WIENET FS 8-PN-W, WIENET FS 8-EI-W.
Figure 3.4 Rear View
16 Wieland Electric GmbH | BA001047 (Rev. A) | 06/2018
The following view applies to WIENET FS 16-PN-W, WIENET FS 16-EI-W.
No.
Item
Description
1
DIN-Rail mounting
plate
Mounting plate used for the installation to a standard DIN rail.
3 Product Overview
Figure 3.5 Rear View
Wieland Electric GmbH | BA001047 (Rev. A) | 06/2018 17
3 Product Overview
No.
Item
Description
1
Terminal block
Connect cabling for power and alarm wiring.
No.
Item
Description
1
Terminal block
Connect cabling for power and alarm wiring.
1
1
3.2.3 Top View
The following view applies to WIENET FS 8-PN-W, WIENET FS 8-EI-W.
Figure 3.6 Top View
The following view applies to WIENET FS 16-PN-W, WIENET FS 16-EI-W.
Figure 3.7 Top View
18 Wieland Electric GmbH | BA001047 (Rev. A) | 06/2018
3.2.4 Bottom View
No.
Item
Description
1
Ground Terminal
Screw terminal used to ground chassis.
No.
Item
Description
1
Ground Terminal
Screw terminal used to ground chassis.
1
1
The following view applies to WIENET FS 8-PN-W, WIENET FS 8-EI-W.
Figure 3.8 Bottom View
The following view applies to WIENET FS 16-PN-W, WIENET FS 16-EI-W.
3 Product Overview
Figure 3.9 Bottom View
Wieland Electric GmbH | BA001047 (Rev. A) | 06/2018 19
4 Switch Installation
4 Switch Installation
4.1 Installation Guidelines
The following guidelines are provided to optimize the device performance. Review the guidelines before
installing the device.
Make sure cabling is away from sources of electrical noise. Radios, power lines, and fluorescent
lighting fixtures can interference with the device performance.
Make sure the cabling is positioned away from equipment that can damage the cables.
Operating environment is within the ranges listed range, see "Specifications" in section 3.1.
Relative humidity around the Switch does not exceed 95 percent (noncondensing).
Altitude at the installation site is not higher than 10,000 feet.
In 10/100 fixed port devices, the cable length from the Switch to connected devices can not exceed
100 meters (328 ft).
Make sure airflow around the Switch and respective vents is unrestricted. Without proper airflow
the Switch can overheat. To prevent performance degradation and damage to the Switch, make
sure there is clearance at the top and bottom and around the exhaust vents.
4.1.1 Connecting Hardware
These instructions will explain how to find a proper location for your Switch, how to connect to the network, hook up the power cable, and connect to wienet FS 8/16-XX-W.
4.2 Verifying Switch Operation
Before installing the device in a rack or on a wall, power on the Switch to verify that the Switch passes the
power-on self-test (POST). To connect the cabling to the power source, see "Power Supply Installation" in
section 4.5.
At startup (POST), the System LED blinks green, while the remaining LEDs are a solid green. Once the
Switch passes POST self-test, the System LED turns green. The other LEDs turn off and return to their
operating status. If the Switch fails POST, the System LED Switches to an amber state.
After a successful self-test, power down the Switch and disconnect the power supply. The Switch is now
ready for installation on its final location.
20 Wieland Electric GmbH | BA001047 (Rev. A) | 06/2018
4 Switch Installation
NOTE
Figure 4.1 Installing the DIN-Rail Mounting Kit
DIN Rail
1
2
DIN Rail
1
2
Figure 4.2 Removing the DIN-Rail
4.3 Installing the Switch
4.3.1 DIN Rail Mounting
The DIN rail mount option is the quickest installation option. Additionally, it optimizes the use of rail space.
The metal DIN rail kit is secured to the rear of the Switch. The device can be mounted onto a standard
35mm (1.37") x 75 mm (3") height DIN rail. The devices can be mounted vertically or horizontally. Refer to
the following guidelines for further information.
Note
A corrosion-free mounting rail is advisable.
When installing, make sure to allow for enough space to properly install the cabling.
4.3.1.1 Installing the DIN-Rail Mounting Kit
1. Insert the top back of the mounting bracket over the DIN rail.
2. Push the bottom of the Switch towards the DIN rail until it snaps into place.
4.3.1.2 Removing the DIN-Rail Mounting Kit
1. Push the Switch down to free the bottom of the plate from the DIN rail.
2. Rotate the bottom of the device towards you and away from the DIN rail.
3. Once the bottom is clear of the DIN rail, lift the device straight up to unhook it from the DIN
rail.
Wieland Electric GmbH | BA001047 (Rev. A) | 06/2018 21
4 Switch Installation
NOTE
Figure 4.3 Installing Wall Mount Plates
Figure 4.4 Securing Wall Mounting Screws
4.5 mm
3.0 mm
2.0 mm
4.3.2 Wall-Mounting
The wall mounting option provides better shock and vibration resistance than the DIN rail vertical mount.
Note
When installing, make sure to allow for enough space to properly install the cabling.
Before the device can be mounted on a wall, you will need to remove the DIN rail plate.
1. Rotate the device to the rear side and locate the DIN mounting plate.
2. Remove the screws securing the DIN mounting plate to the rear panel of the Switch.
3. Remove the DIN mounting plate. Store the DIN mounting plate and provided screws for later
use.
4. Align the wall mounting plates on the rear side. The screw holes on the device and the mount-
ing plates must be aligned, see the following illustration.
5. Secure the wall mount plates with M3 screws, see the following figure. Once the wall mount-
ing plates are secure on the device, you will need to attach the wall screws (x3).
6. Locate the installation site and place the Switch against the wall, making sure it is the final
installation location.
7. Use the wall mount plates as a guide to mark the locations of the screw holes.
8. Drill four holes over the four marked locations on the wall, keeping in mind that the holes must
accommodate wall sinks in addition to the screws.
9. Insert the wall sinks into the walls.
10. Insert the screws into the wall sinks. Leave a 2 mm gap between the wall and the screw head
to allow for wall mount plate insertion.
22 Wieland Electric GmbH | BA001047 (Rev. A) | 06/2018
4 Switch Installation
NOTE
Figure 4.5 Wall Mount Installation
Note
Make sure the screws dimensions are suitable for use with the wall mounting plate.
Do not completely tighten the screws into the wall. A final adjustment may be needed before fully securing the wall
mounting plates on the wall.
11. Align the wall mount plate over the screws on the wall.
12. Install the wall mount plate on the screws and slide it forward to lock in place, see the following
figure.
13. Once the device is installed on the wall, tighten the screws to secure the device.
Wieland Electric GmbH | BA001047 (Rev. A) | 06/2018 23
4 Switch Installation
Straight-thru Cable Wiring
Cross-over Cable Wiring
Pin 1
Pin 1
Pin 1
Pin 3
Pin 2
Pin 2
Pin 2
Pin 6
Pin 3
Pin 3
Pin 3
Pin 1
Pin 6
Pin 6
Pin 6
Pin 2
Figure 4.6 Ethernet Plug & Connector Pin Position
8
1
4.4 Connecting the Switch to Ethernet Ports
4.4.1 RJ45 Ethernet Cable Wiring
For RJ45 connectors, data-quality, twisted pair cabling (rated CAT5 or better) is recommended. The connector bodies on the RJ45 Ethernet ports are metallic and connected to the GND terminal. For best performance, use shielded cabling. Shielded cabling may be used to provide further protection.
Maximum cable length: 100 meters (328 ft.) for 10/100BaseT.
24 Wieland Electric GmbH | BA001047 (Rev. A) | 06/2018
4 Switch Installation
WARNING
ATTENTION
ATTENTION
NOTE
Single
Redundant
Figure 4.7 Power Wiring for wienet FS 8/16-EI-W
4.5 Power Supply Installation
4.5.1 Overview
Warning!
Power down and disconnect the power cord before servicing or wiring the Switch.
Attention!
Do not disconnect modules or cabling unless the power is first switched off.
The device only supports the voltage outlined in the type plate. Do not use any other power components except
those specifically designated for the switch device.
Attention!
Disconnect the power cord before installation or cable wiring.
The Switches can be powered by using the same DC source used to power other devices. A DC voltage
range of 12 to 48 VDC must be applied between the V1+ terminal and the V1-terminal (PW1), see the
following illustrations. A Class 2 power supply is required to maintain a UL60950 panel listing. The chassis
ground screw terminal should be tied to the panel or chassis ground. A redundant power configuration is
supported through a secondary power supply unit to reduce network down time as a result of power loss.
GND
GND
4.5.2 Considerations
Take into consideration the following guidelines before wiring the device:
The Terminal Block (CN1) is suitable for 12 24 AWG (3.31 0.205 mm2). Torque value 0.8 Nm
(7 lb-in).
The cross sectional area of the earthing conductors shall be at least 4 mm2.
Calculate the maximum possible current for each power and common wire. Make sure the power
draw is within limits of local electrical code regulations.
For best practices, route wiring for power and devices on separate paths.
Do not bundle together wiring with similar electrical characteristics.
Make sure to separate input and output wiring.
Label all wiring and cabling to the various devices for more effective management and servicing.
Note
Routing communications and power wiring through the same conduit may cause signal interference. To avoid interference and signal degradation, route power and communications wires through separate conduits.
Wieland Electric GmbH | BA001047 (Rev. A) | 06/2018 25
4 Switch Installation
ATTENTION
ATTENTION
ATTENTION
ATTENTION
ATTENTION
NOTE
Connection to
Drain Wire with Lug
Figure 4.8 Grounding Connection
4.5.3 Grounding the device
Attention!
Do not disconnect modules or cabling unless the power is first switched off.
The device only supports the voltage outlined in the type plate. Do not use any other power components except
those specifically designated for the switch device.
Attention!
Before connecting the device properly ground the device. Lack of a proper grounding setup may result in a safety
risk and could be hazardous.
Attention!
Do not service equipment or cables during periods of lightning activity.
Attention!
Do not service any components unless qualified and authorized to do so.
Attention!
Do not block air ventilation holes.
Electromagnetic Interference (EMI) affects the transmission performance of a device. By properly grounding the device to earth ground through a drain wire, you can setup the best possible noise immunity and
emissions.
Grounding Point
By connecting the ground terminal by drain wire to earth ground the Switch and chassis can be ground.
Note
Before applying power to the grounded Switch, it is advisable to use a volt meter to ensure there is no voltage difference between the power supply's negative output terminal and the grounding point on the Switch.
26 Wieland Electric GmbH | BA001047 (Rev. A) | 06/2018
4 Switch Installation
ATTENTION
WARNING
DC 12 48V
PWR2
1A@24V
PWR1
V2- V2+ V1- V1+
P-Fail
Figure 4.9 Terminal Receptor: Relay Contact
DC 12 48V
PWR2
1A@24V
PWR1
V2- V2+ V1- V1+
P-Fail
Figure 4.10 Terminal Receptor: Power Input Contacts
4.5.4 Wiring a Relay Contact
The following section details the wiring of the relay output. The terminal block on the wienet FS 8/16-XXW is wired and then installed onto the terminal receptor located on the wienet FS 8/16-XX-W.
The terminal receptor includes a total of six pins: two for PWR1, two for PWR2 and two for a fault circuit.
4.5.5 Wiring the Power Inputs
Attention!
Do not disconnect modules or cabling unless the power is first switched off.
The device only supports the voltage outlined in the type plate. Do not use any other power components except
those specifically designated for the switch device
Warning!
Power down and disconnect the power cord before servicing or wiring the Switch.
There are two power inputs for normal and redundant power configurations. The power input 2 is used for
wiring a redundant power configuration. See the following for terminal block connector views.
To wire the power inputs:
Make sure the power is not connected to the Switch before proceeding.
1. Loosen the screws securing terminal block to the terminal block receptor.
Wieland Electric GmbH | BA001047 (Rev. A) | 06/2018 27
4 Switch Installation
Figure 4.11 Removing a Terminal Block
Figure 4.12 Installing DC Wires in a Terminal Block
Loosening Wire-clamp Screws
Installing DC Wires
Securing Wire-clamp Screws
Figure 4.13 Installing DC Wires in a Terminal Block
2. Remove the terminal block from the Switch.
3. Insert a small flat-bladed screwdriver in the V1+/V1- wire-clamp screws, and loosen the
screws.
4. Insert the negative/positive DC wires into the V+/V- terminals of PW1. If setting up power
redundancy, connect PW2 in the same manner.
5. Tighten the wire-clamp screws to secure the DC wires in place.
28 Wieland Electric GmbH | BA001047 (Rev. A) | 06/2018
4 Switch Installation
Figure 4.14 Securing a Terminal Block to a Receptor
6. Align the terminal block over the terminal block receptor on the Switch.
7. Insert the terminal block and press it in until it is flush with the terminal block receptor.
8. Tighten the screws on the terminal block to secure it to the terminal block receptor.
If there is no gap between the terminal block and the terminal receptor, the terminal block is seated correctly.
Wieland Electric GmbH | BA001047 (Rev. A) | 06/2018 29
5 Managing Switch
NOTE
NOTE
5 Managing Switch
5.1 First Time Setup
5.1.1 Overview
The Industrial Ethernet Managed Switch is a configurable device that facilitates the interconnection of
Ethernet devices on an Ethernet network. This includes computers, operator interfaces, I/O, controllers,
RTUs, PLCs, other switches/hubs or any device that supports the standard IEEE 802.3 protocol.
This Switch has all the capabilities of a store and forward Ethernet switch plus advanced management
features such as SNMP, RSTP and port mirroring. This manual details how to configure the various management parameters in this easy to use switch.
5.1.2 Introduction
To take full advantage of all the features and resources available from the Switch, it must be configured
for your network.
The Switch implements Rapid Spanning Tree Protocol (RSTP) and Simple Network Management Protocol
(SNMP) to provide most of the services offered by the Switch. Rapid Spanning Tree Protocol allows managed Switches to communicate with each other to ensure that there exists only one active route between
each pair of network nodes and provides automatic failover to the next available redundant route. A brief
explanation of how RSTP works is given in the Spanning Tree section.
The Switch is capable of communicating with other SNMP capable devices on the network to exchange
management information. This statistical/derived information from the network is saved in the Management Information Base (MIB) of the Switch. The MIB is divided into several different information storage
groups. These groups will be elaborated in detail in the Management and SNMP information section of this
document. The Switch implements Internet Group Management Protocol (IGMP) to optimize the flow of
multicast traffic on your network.
The Switch supports both port-based and tag-based Virtual LANs for flexible integration with VLAN-aware
networks with support for VLAN-unaware devices.
5.1.3 Administrative Interface Access
There are several administrative interfaces to the Switch:
1. A graphical web interface accessible via the Switch's built-in web server, supporting HTTP.
Note
This is the recommended method for managing the Switch.
2. An SNMP interface can be used to read/write many settings
5.1.4 Using the Graphical (Web) Interface
The graphical interface is provided via a web server in the Switch and can be accessed via a web browser
such as Opera, Mozilla, or Internet Explorer.
Note
JavaScript must be supported and enabled in your browser for the graphical interface to work correctly.
HTTP and HTTPS (secure HTTP) are supported for access to the web server. By default, both protocols are
enabled. Either or both may be disabled to secure the Switch. (See the Remote Access Security topic in
this section.)
To access the graphical interface, enter a URL like HTTP:// 10.0.50.1 in your browser's address bar. Replace
"http" with "https" to use secure http and replace "10.0.50.1" with your Switch's IP address if you have
changed it from the factory default.
30 Wieland Electric GmbH | BA001047 (Rev. A) | 06/2018