SNV 4063KP
MONITORING OF EMERGENCY STOP, SAFETY GATES AND LIGHT BARRIERS, ON-DELAYED
APPLICATIONS
• Protection of people and machinery
• Monitoring of emergency stop applications
• Monitoring of safety gates
• Monitoring of light barriers
• Monitoring of interlocking installation with position
switches and integrated locking
• Control of spring-actuated interlocks
• Up to PL e / Category 4 (EN ISO 13849-1)
] L Y t
• Up to SIL
FEATURES
• Stop Category 0 according to EN 60204-1
• Single-channel or two-channel control
• Manual or automatic start
• ON-delay time adjustable in the range 0.15 to 3 s or 1.5 to 30 s
• Reset button monitoring, cross monitoring
• 3 enabling current paths (2 undelayed, 1 ON-delayed)
3 (EN 62061)
CL
FUNCTION
With supply voltage applied to terminals A1/A2, relays K3 and K4
(terminals 37/38) start with the pre-selected ON-delay time. The
ON-delay time t
or 1.5 to 30 s according to the device type. The device is enabled by
pressing the reset button. The following operating modes can be
selected:
can be adjusted infinitely in the range 0.15 to 3 s
A1
CIRCUIT DIAGRAM
SNV 4063KP
• Manual start – The reset button must be connected to S34
through terminal S33. For starting the relay, the reset button must
be pressed. Relays K3 and K4 (terminals 37/38) will switch into the
OFF position. With the falling edge of the reset signal, the reset is
completed and activates relays K1 and K2, which become
self-locking after the response time tA3. After this switch-on
phase, the 2 enabling current paths defined for the output are
closed (terminals 13/14, 23/24). With the emergency stop command, the power supply to relays K1 and K2 is interrupted. The
enabling current paths (terminals 13/14, 23/24) are immediately
opened with release time tR, and relays K3 and K4 will start after
the pre-set ON-delay time tA1, terminals 37/38. Three LEDs
display the state of relays K1/K2, K3/K4 and the supply voltage.
• Automatic start – For monitoring of interlocking installations
with locking mechanism or safety gate applications in which on
automatic start shall be performed it is necessar y to jumper
terminals S33/S35. The device will react at the rising edge of input
S12 that is internally connected to S33. Relays K3 and K4 (terminals 37/38) will switch into the OFF position. With the rising edge
of input S12 the relay K1 is activated and response time tA2
started. When the time has elapsed, the 2 enabling current paths
are closed (terminals 13/14, 23/24). With a stop command the
power supply to relays K1 and K2 is interrupted. The enabling
current paths (terminals 13/14, 23/24) are immediately opened
with release time tR, and relays K3 and K4 will start after the
pre-set ON-delay time tA1, terminals 37/38.
.
64
safe RE LAY

OVERVIEW OF DEVICES | PART NUMBERS
Typ e Time range Rated voltage Ter minals Part no. P.U .
SNV 4063KP-A 3 s 24 V DC R1.188.0660.0 1
30 s 24 V DC R1.188.0680.0 1
TECHNICAL DATA
Function Emergency stop relay for access delay combined with locking mechanism
Function display 3 LEDs, green
Function mode / adjustment Time / stepless
Adjustment range 0.15 - 3 s / 1.5 - 30 s
Power supply circuit
Rated voltage U
N
A1, A2 24 V DC
Rated consumption 24 V DC 2.6 W
Operating voltage range U
B
Electrical isolation supply circuit - control circuit no
Control circuit
Rated output voltage S11, S33/S21 22 V DC
Input current / peak current S12, S31/S22 25 mA / 100 mA
S34, S35 40 mA / 50 mA
Response time t
Minimum ON time t
Recover y time t
Release time t
Release time t
Synchronous time t
Permissable test pulse time t
Max. resistivity, per channel
/ t
A1
A2
M
W
R
, delayed contacts (tolerance) 0.15 - 3 s / 1.5 - 30 s (±16 %)
R
S
TP
1)
Output circuit
Enabling paths 13/14, 23/24 normally open contact
37/ 38 normally open contact, ON-delayed
Contact assignment forcebly guided
Contact type Ag-alloy, gold-plated
Rated switching voltage enabling path 230 V AC
Max. thermal current I
Max. total current I
2
of all current path (Tu = 55 ºC) 5 A²
th
enabling path 6 A
Application category (NO) AC-15 U
DC-13 U
Short-circuit protection (NO), lead fuse / circuit breaker 6 A Class gG / melting integral < 100 A²s
Mechanical life 10
General data
Creepage distances and clearances between the circuits EN 6066 4-1
Protection degree according to EN 60529 (housing / terminals) IP40 / IP20
Ambient temperature / storage temperature -25 ºC - +55 ºC / -25 ºC - + 75 ºC
Wire ranges screw terminals, fine-stranded / solid 1 x 0.2 mm² – 2.5 mm² / 2 x 0.2 mm² – 1.0 mm²
fine-stranded with ferrules 1 x 0.25 mm² – 2.5 mm² / 2 x 0.25 mm² – 1.0 mm²
Permissible torque 0,5 - 0,6 Nm
Wire ranges push-in terminals 1 x 0.25 mm² – 1.5 mm²
Weight 0.20 kg
Standards EN ISO 13849-1, EN 62061, EN 50156-1
Approvals TÜV, GL, cULus, CCC
1)
If two-channel devices are installed as single channel, the value is halved.
Screw terminals, pluggable
Screw terminals, pluggable
0.85 - 1.1 x U
N
30 ms / 700 ms
200 ms
500 ms
25 ms
500 ms
< 1 ms
≤ (5 + (1.176 x UB / UN - 1) x 100) Ω
230 V, Ie 3 A
e
24 V, Ie 2 A
e
7
switching cycles
safe RELAY
safe RE LAY
.
65