SPECIFICATION
Steel plate to BS EN 10025 S235 & S275 Steel CHS to BS EN 10219 S235, S275 & S355 Steel Bar to 10025 S275 and 10277 Welding to EN ISO 14341:2011 Polyester powder paint to EN 13438:2005
PROD. CODE SIZE AGE RANGE
F/ FALL HEIGHT HEAVIEST PART TOTAL WEIGHT
Standard fixings to BS 3692:2001 and BS 4190:2001 Non-standard fixings are anti-vandal and corrosion resistant
6060-111
1545 x 620 x 530
6 - 16 Years
Max 1000mm
Approx 105Kg
Approx 134Kg
INSTALLATION INSTRUCTIONS
1. Read instructions thoroughly before commencing installation of unit.
2. Excavate foundations as shown on the foundation plan.
3. Position and assemble the below ground fixing with spragging irons (see page 2) centrally in the excavated hole ensuring that it is at the correct height and the top plate is flush with the finished surface level.
4. Backfill with 0.28 m³ concrete (4 parts gravel, 2 parts sand & 1 part cement).
5. Allow concrete to set for a period of 48 hours.
6. Fit the Suspension Unit Assembly/Buddy Board Assembly to the below ground fixing as shown on page 5.
7. Ensure that all fastenings are fully tightened.
Note
Note
Ensure all installation aids are removed before first use.
6060-111 Page 1 of 9
Foundation Detail (Care must be taken in abnormal conditions)
4
2
700
350
350
700
FSL
600
Spragging Irons
Concrete
Foundation Detail (Care must be taken in abnormal conditions)
Bark Fix
3
4
700
350
350
700
FSL
400
1000
Bark
Concrete
Spragging Iron
FSL = Finished Surface Level
6060-111 Page 2 of 9
Minimum Space
4650
3550
R1775
Minimum Space
1545
170
620
421
Top of Suspension
Assembly Plate
6060-111 Page 3 of 9
Safety Surfacing
4650
Wetpour
14.0 Sq. Metres 40mm Wetpour
13.5 Linear Metres Wetpour Edging
Grass Mats (1500 x 1000mm)
14 off Total
2325
3550
R1775
6000
500 2500
Safety Tiles (1000 x 1000mm)
18.0 Sq. Metres 40mm Thickness
16.0 Linear Metres of Tile Edging
4000
5000
2500
4000
6060-111 Page 4 of 9