Whynter RPD-503SP User Manual

Whynter Energy Star 50 pint Portable Dehumidifier with
Pump / Slate Gray
Model # : RPD-503SP
INSTRUCTION MANUAL
Congratulations on your new Whynter product. To ensure proper operation, please read this Instruction Manual carefully before
using this product. Keep this manual in a safe place for future reference.
DISPOSAL INFORMATION
Thank you for choosing the Whynter Portable Dehumidifier. Please follow the instructions provided in this user guide to obtain the very best performance from your dehumidifier. We trust that your Whynter dehumidifier will provide
the performance and reliability that we stand for.
Your Whynter dehumidifier is designed to remove moisture in the air by con­densation removal and collecting the condensation water in the internal water
bucket or draining through a drain hose.
Please keep this user manual in a safe place for future reference.
correct disposal of this product protects the environment.
Further information about the recycling of this product can be obtained from
your local municipal authority.
2
TABLE OF CONTENTS
PAGE
DISPOSAL INFORMATION
SAFETY PRECAUTIONS
INTRODUCTION
PARTS AND CONTROLS
OPERATION INSTRUCTIONS
CONTINUOUS DRAINAGE
MAINTENANCE
TIPS ON WHEN TO USE YOUR PORTABLE DEHUMIDIFIER
TROUBLESHOOTING
2
4
5
6
7 - 8
9
10
11
12 - 13
WARRANTY INFORMATION
14
3
SAFETY PRECAUTIONS
TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY
WARNING
Read all instructions before using the appliance Never clean appliance parts with flammable fluids. The fumes can create a fire hazard. Do not use an exces-
sively wet cloth, industrial solvents, and oil-based products to clean this appliance
Do not store or use gasoline or any other flammable vapors and liquids in the vicinity of this or any other appli-
ance. The fumes can create a fire hazard
Do not abuse, sit on, or stand on the appliance This appliance is not intended for use by persons (including children with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction con­cerning use of the appliance by a person responsible for their safety
Children should be supervised to ensure that they do not play with the appliance
If the power cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly quali-
fied person in order to avoid a hazard
Please dispose of packing materials properly
Use the portable dehumidifier only for its intended function. This appliance is designed for household, non-
commercial use only. Any other use will void the warranty
To avoid the risk of shock, the product should never be used in bathrooms, shower rooms, or in any other
steamy or wet areas
During installation, the power supply must not be excessively or dangerously bent or flattened Do not tamper with controls Make sure the plug is placed fully and firm into the wall socket. If the wall receptacle you intend to use is not
adequately grounded or protected by a time delay fuse or circuit breaker, have a qualified electrician install an outlet that is appropriate to local electrical codes and requirements
Do not use multiple socket. Do not use multiple socket or of an extension cord as it may overheat and become
a risk of fire.
Make sure the plug is clean before usage Do not turn this appliance on and off by plugging and unplugging. Always use the ON/OFF switch After turning the appliance off, please take the plug out of the socket
Make sure hands are dry when connecting the power plug. The appliance is equipped with a three-prong
grounded plug on the power cord for your protection. Never modify, remove or attempt to repair the plug your­self
Do not repair, disassemble and/or modify the appliance by yourself Always turn off the appliance when cleaning the air filter, and transporting
At the end of each season, all water must be drained from the appliance and air filter must be cleaned before
storage
Do not drink or use the water collected or drained from the appliance Do not remove the water bucket during operation Transport the appliance in an upright position only, or leave it in an upright position for at least 2 hours before
first use
When positioning or moving the appliance, ensure that it is not turned upside down or greater than 45° or more
off level.
This appliance must be installed in an area protected from the element, such as wind, rain, water spray or
drips
Always place the appliance on even and hard and level surface that can support the unit when it is full Ensure objects are not obstructing the exhaust and air intake
Never insert your fingers or other objects into the air intakes and air outlets Do not operate the appliance without the air filter
WHEN USING YOUR PORTABLE DEHUMIDIFIER, FOLLOW THESE BASIC PRECAUTIONS:
THE MANUFACTURER DISCLAIMS ANY RESPONSIBILITY IF THE ABOVE INSTRUCTIONS ARE NOT
FOLLOWED
4
INTRODUCTION
How it Works
When the dehumidifier is started, the fan begins to pull moisture-laden air across the dehumidifying
coils. The coils condense or draw moisture from the air, and air flows through the top louver into the room as dry, warm air. Moisture removed from air is collected in a water bucket on the front of the
dehumidifier.
The appliance is designed to operate between 41°F (5°C), and 96°F (35°C). The compressor circuit has an automatic 3 minute time delayed start if the appliance is turned off and on quickly. This prevents overheating of the compressor and possible circuit breaker tripping. Make sure the water bucket is fitted
correctly otherwise appliance will not turn on.
Energy Saving Guide
This Whynter dehumidifier is an Energy Star rated appliance. Follow the guide below can help to get
the best performance and efficiency from your dehumidifier.
Do not cover the air intake and outlet.
Do not place the appliance in front of curtains or drapes - to ensure they do not obstruct the air
intake.
Keep curtains, blinds or drapes closed during the sunniest part of the day.Close all windows and doors.Indoor relative humidity should ideally be kept between 35%RH and 60%RH depending on the
ambient temperature.
Make sure the appliance is on a hard and level surface.To prolong the compressor's life, please wait at least 3 minutes before turning the appliance back
on after shutting it off.
Inspect and keep the air filter clean by cleaning regularly.Perform routine maintenance.
TECHNICAL DATA
Dehumidifying capacity 50 pints / day
Drain Bucket Capacity
Maximum power input 950W
Current Consumption
Air flow M3/H / CFM
MODEL : RPD-503SP
18 pints / day
Power supply 115v/ 60Hz
497 Watts / 4.7 Amps
Refrigerant R-410A / 260g
173M3H/102 CFM
Fan speeds 2 (H & L)
Unit Dimensions
Unit Net Weight 38 lbs
(22” in H when casters are not installed)
24” H x 15” W x 12” D
Unit Gross Weight 42 lbs Noise Level (dBA) 53.5
5