Whynter MSFS-012H23017-01NE, MSFS-012H11517-01NE, MSFS-009H11517-01NE, MSFS-012H11522-01ES Operation Manual

Congratulations on your new Whynter product. To ensure proper operation, please read this Instruction Manual carefully before
using this product. Keep this manual in a safe place for future reference.
OPERATION MANUAL
Whynter Mini Split Inverter Ductless Air Conditioner System
Air Conditioner & Heat Pump
For models: MSFS-009H11517-01NE MSFS-012H11517-01NE MSFS-012H23017-01NE MSFS-012H11522-01ES
V 6.7.2017-1036
2
TABLE OF CONTENTS
PAGE
DISPOSAL INFORMATION
3
SAFETY PRECAUTIONS
4
INTRODUCTION
5
TECHNICAL DATA
7
PARTS IDENTIFICATION
8
OPERATING TEMPERATURE / USING THE REMOTE CONTROL
9
FEATURES OF THE REMOTE CONTROL / DISPLAY
10 - 11
MODES OF OPERATION INSTRUCTIONS
12 - 13
SPECIAL FUNCTION FEATURES / DISPLAY PANEL
14 - 15
CARE AND MAINTENANCE
16 - 17
OPERATION TIPS
18 - 19
TROUBLESHOOTING
20 - 21
WARRANTY INFORMATION
22
3
DISPOSAL INFORMATION
This symbol on the product or its packaging indicates that the appliance cannot be treated as nor­mal domestic trash, but must be handed in at a collection point for recycling electric and electronic appliances. Your contribution to the correct disposal of this product protects the environment. Fur­ther information about the recycling of this product can be obtained from your local municipal au­thority.
Thank you for choosing the Whynter Mini Split Inverter Ductless Air Conditioner System Air Conditioner & Heat Pump. Please follow the instructions provided in this user guide to obtain the very best performance from your split air conditioner and take full advantage of the many fea­tures your air conditioner offers you. We trust that your Whynter air conditioner will provide the per­formance and reliability that we stand for.
Please keep this user manual in a safe place for future reference.
4
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY WHEN USING YOUR AIR CONDIITIONER, FOLLOW THESE BASIC PRECAUTIONS:
Before the appliance is used, it must be properly positioned and installed as detailed in this manual.
Please read this manual entirely before installing and using this appliance and follow all instructions and gen -
eral safety rules carefully. High voltages and pressures existing within this unit can cause serious harm to persons or property or even death. Installation must be performed in accordance with the requirement of NEC and CEC by authorized certified HVAC contractor only. Improper installation will cause irreversible dam­ages and serious safety risks.
Installation must be performed according to all applicable and current national and local codes, regulations
and laws.
During the installation, the area within the indoor and outdoor sections of this split system must be restricted
to all unauthorized personnel to avoid any accidents.
Both indoor and the outdoor units must be firmly fixed to the proper parts of the building’s structure.
Sensitive components in this unit are protected by a fuse installed on the electronic card located in the indoor
unit. Rating of this fuse is 5 Amps / 250 V. Only replace the fuse with the same rating when needed.
System power should be attached to the outdoor unit through a properly rated independent power circuit pro-
tected by a properly rated circuit breaker and a service disconnect switch box located near the outdoor unit.
Ensure that the incoming voltage corresponds with the required power written on the rating plate. Make all
connections tightly and waterproof to avoid risk of electrical shocks or fire due to insufficient contact.
All power wires, breakers and other components used to supply power to the unit must be approved for such
use and properly rated for the load.
Always disconnect power before servicing.
This unit contains no user-serviceable parts. Always consult authorized service personnel for installation, re-
pairing, and relocation of this product. Improper installation or handling will cause leakage, electrical shock, or fire.
If any parts such as the power cord is damaged, replacement or repair work shall be performed by authorized
personnel only.
This appliance is not intended for use by persons (including children) with reduced physical, sensory or men-
tal capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by persons responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
In the event of a malfunction such as burning smell, immediately stop operation of the air conditioner, and
disconnect all the power supply by turning off the electrical breaker or disconnecting the power plug. Then consult authorized HVAC service personnel.
In the event of refrigerant leakage, be sure to keep away from fire or any flammables, and consult authorized
HVAC service personnel.
Ensure that any electronic equipment is at least 1 meter / 3 feet away from either the indoor unit or outdoor
unit.
Do not climb on, place objects on, or hang objects from the unit.
Do not expose the unit directly to water.
Do not insert your fingers or any other objects into outlet port, open panel, or intake grille.
SAFETY PRECAUTIONS
THE MANUFACTURER DISCLAIMS ANY RESPONSIBILITY IF THE ABOVE INSTRUCTIONS ARE NOT FOLLOWED.
5
THE MANUFACTURER DISCLAIMS ANY RESPONSIBILITY IF THE ABOVE INSTRUCTIONS ARE NOT FOLLOWED.
CAUTION
TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY WHEN USING YOUR AIR CONDIITIONER, FOLLOW THESE BASIC PRECAUTIONS:
Air always contains some level of humidity. Any air left within the system or entering into the system will cause
insufficient performance and irreversible internal compressor damage.
Installer must carry out cycle tests and monitor and record of all related operational data before leaving the
scene.
Do not locate the system components near any inflammable substances, pressurized containers and moisture
containing items.
All packing materials are recyclable, please discard properly.
Operate and regularly maintain the system as instructed in this manual.
Warranty is valid only when the equipment is installed properly by licensed HVAC contractors and the warranty
registration card must be properly filled out and sent to the manufacturer.
System components must be installed where they can be accessed for maintenance and repairs easily. Suffi-
cient clearances must be provided at all directions for removal of various panels.
If you see lightning or hear thunder, there might be a lightning strike. To prevent electric shock hazard, turn off
the air conditioner by using the remote control, and do not touch the unit or the power plug during thunder­storm.
Always operate the unit with air filters installed.
Always turn off the appliance when cleaning the air filter, and transporting.
Unplug the power supply cable when not using the indoor unit for an extended period.
Do not block or cover the intake grille and the outlet port.
Do not place any other electrical products or household items under indoor unit or outdoor unit as dripping
condensation from the unit might get them wet, and may cause damage or malfunction of your property.
Do not abuse, sit on, or stand on the appliance.
Do not drink or let pet(s) drink the drainage from the air conditioner.
Do not touch the aluminum fins of heat exchanger built-in the indoor or outdoor unit to avoid personal injury
when you install or maintain the unit.
Do not operate with wet hands.
The design and specifications are subject to change without prior notice for product improvement.
SAFETY PRECAUTIONS
IMPORTANT
This Whynter Mini Split Inverter Ductless Air Conditioner system is designed to be a one-to-one unit system, consisting of 1 indoor unit matched with 1 outdoor unit. Multiple indoor unit(s) cannot be combined with the outdoor unit. If indoor or outdoor units are purchased individually, ensure that indoor and outdoor unit are compatible with each other before purchasing to avoid performance and operation issues.
6
INTRODUCTION
The advanced inverter technology used in the Whynter Mini Split Inverter Ductless Air Conditioners is the latest evolution of technology concerning the electro motors of the compressors. An inverter is used to control the speed of the compressor motor, so as to continuously regulate the temperature.
When the inverter air conditioning is switched on, the compressor operates at a high speed in order to cool or heat the room quickly. As the room temperature approaches the set temperature, the compressor slows down, maintaining a constant temperature and saving energy. Any sudden fluctuation in the room tempera­ture will be sensed and instantly adjusted to bring the room temperature back to the set temperature. Below are the advantages of inverter technology.
- At least 30% - 50% less expensive to run as it consumes less power
- Quicker to achieve desired temperature
- Quieter operation
- No temperature fluctuations
- No voltage peaks from compressor
HOW IT WORKS
Ductless Mini Split system is the newest thing to hit the HVAC industry. This is a new and energy efficient way to cool and heat a living or working space. The technology goes by many names – ductless air condi­tioning, mini split air conditioner, mini ductless ac and others.
Ductless Mini Split systems use 2 units, One Inside (Indoor unit; the evaporator) and One Outside (Outdoor unit; the condenser). Essentially, this is an air conditioner that is split into 2 units, similar to central air con­ditioning. The difference is that split air conditioning consists of 2 units that are placed relatively close to each other. Best of all, you do not need to perform any additional ductwork in your home, because this technology uses no ducts at all.
The outside unit is the compressor unit, just like you`d see in a central air conditioner system. The inside unit simply hangs on the wall, and hoses and wires connect the 2 units together.
There are many advantages to Ductless Mini Split systems:
1. The installation is simple and quick.
2. The system is energy efficient because:
Cooled air is not blown through duct work. Energy wasted in long lengths of uninhabited ductwork
means higher energy bills.
With Central Air you must cool an entire home when only one room may need cooling. On the other
hand, ductless mini-splits cool only the areas you want and not the areas you don’t.
3. The air conditioner is also a mini split heat pump, so you get year -round use of the unit.
4. Ultra quiet operation as the louder components like compressors and motors are installed outdoors.
7
TECHNICAL DATA
Full Set
Model#:
MSFS-009H11517-01NE MSFS-012H11517-01NE MSFS-012H11522-01ES MSFS-012H23017-01NE
Indoor Unit
Model#:
MSI-009H11517-01NE MSI-012H11517-01NE MSI-012H11522-01ES MSI-012H23017-01NE
Outdoor Unit
Model#:
MSO-009H11517-01NE MSO-012H11517-01NE MSO-012H11522-01ES MSO-012H23017-01NE
Operational
Modes:
Auto, Cool, Fan,
Dry, and Heat
Auto, Cool, Fan,
Dry, and Heat
Auto, Cool, Fan,
Dry, and Heat
Auto, Cool, Fan,
Dry, and Heat
Cooling Capacity:
9000 BTU 12000 BTU 12000 BTU 12000 BTU
Heating Capacity:
9500 BTU 12000 BTU 12000 BTU 11800 BTU
Coverage Area:
250 - 350 sq. ft
350 - 450 sq. ft.
Dehumidifying
Capacity:
21.6 L 28.8 L 28.8 L 28.8 L
Fan Speed:
3 Fan Speed 3 Fan Speed 3 Fan Speed 3 Fan Speed
Filters:
3M + carbon Filter (2) High Density Filter (2)
3M + carbon Filter (2) High Density Filter (2)
3M + carbon Filter (2) High Density Filter (2)
3M + carbon Filter (2) High Density Filter (2)
Recommended
operating temperature
(cooling/heating):
62° - 90°F / 32° - 86°F
Timer:
24 hour
programmable timer
24 hour
programmable timer
24 hour
programmable timer
24 hour
programmable timer
Noise Level:
< 40 - 24 dBA < 40 - 24 dBA < 44 - 29 dBA < 40 - 24 dBA
Refrigerant:
R410A R410A R410A R410A
Air Flow
(at high speed):
247 CFM 294 CFM 370 CFM 294 CFM
Maximum Power
Consumption:
782W / 7.0Amps 1200W / 10.4Amps 960W / 8.4Amps 1090W / 4.8Amps
Power
Supply:
115 V / 60Hz 115 V / 60Hz 115 V / 60Hz 230 V / 60Hz
EER:
11.5 10.5 12.5 11
SEER:
17 SEER 17 SEER
22 SEER Energy Star
17 SEER
Unit
Dimensions:
29” W x 8” D x 12” H
(Indoor Unit)
31” W x12” D x 22” H
(Outdoor Unit)
32” W x 8” D x 12” H
(Indoor Unit)
31” W x12” D x 22” H
(Outdoor Unit)
32” W x 8” D x 12” H
(Indoor Unit)
32” W x14” x 22” H
(Outdoor Unit)
32” W x 8” D x 12” H
(Indoor Unit)
31” W x12” D x 22” H
(Outdoor Unit)
Package
Dimensions:
32” W x 11” D x 15” H
(Indoor Unit)
36” W x14” D x 24” H
(Outdoor Unit)
35” W x12” D x 15” H
(Indoor Unit)
36” W x14” D x 24” H
(Outdoor Unit)
35” W x 12” D x 15” H
(Indoor Unit)
37” W x16” D x 25”
(Outdoor Unit)
35” W x12” D x 15” H
(Indoor Unit)
36” W x14” D x 24” H
(Outdoor Unit)
Net
Weight:
17 lbs (Indoor Unit)
64 lbs (Outdoor Unit)
19 lbs (Indoor Unit)
66 lbs (Outdoor Unit)
19 lbs (Indoor Unit)
82 lbs (Outdoor Unit)
19 lbs (Indoor Unit)
66 lbs (Outdoor Unit)
Gross Weight:
21 lbs (Indoor Unit)
70 lbs (Outdoor Unit)
23 lbs (Indoor Unit)
71 lbs (Outdoor Unit)
23 lbs (Indoor Unit)
88 lbs (Outdoor Unit)
23 lbs (Indoor Unit)
71 lbs (Outdoor Unit)
UPC (Full Set)
852749006405 852749006436 852749006498 852749006467
UPC (Indoor Unit
852749006412 852749006443 852749006504 852749006474
UPC (Outdoor Unit)
852749006429 852749006450 852749006511 852749006481
350 - 450 sq. ft.
350 - 450 sq. ft.
Thermostat
Control Range
(cooling/heating):
62° - 86°F
62° - 86°F 62° - 86°F
62° - 86°F
62° - 90°F / 32° - 86°F
62° - 90°F / 32° - 86°F
62° - 90°F / 32° - 86°F
Loading...
+ 15 hidden pages