WHYNTER ECO-FRIENDLY 14,000 BTU PORTABLE AIR CONDITIONER
MODEL#: ARC-141BG
Instruction Manual
Congratulations on your new WHYNTER product. To ensure proper operation, please read this
Manual carefully before using this product. Keep this manual in a safe place for future
reference.
Instruction
V 2.2.2017-1708
Page 2
2 | P a g e
TABLE OF CONTENTS
INTRODUCTION 3
SAFETY PRECAUTIONS 4-5
IDENTIFICATION OF ACCESSORIES 6
IDENTIFICATION OF PARTS 7
OPERATING YOUR AIR CONDITIONER 8
INSTALLATION INSTRUCTIONS 9-10
AIR FILTERS INSTALLATION 11
OPERATION INSTRUCTIONS 12-13
WATER DRAINAGE 13
REMOTE CONTROL 14
CARE AND MAINTENANCE 15
TECHNICAL DATA 16
TROUBLESHOOTING 17-18
WARRANTY INFORMATION 19
Page 3
3 | P a g e
Thank you for choosing the Whynter portable air conditioner. Please follow the instructions provided
in this user guide to obtain the very best performance from your portable air conditioner and take full
advantage of the many features your portable air conditioner offers you. We trust that your W hynter
air conditioner will provide the performance and reliability that we stand for.
Please keep this user manual in a safe place for future reference.
DISPOSAL
This symbol on the product or its packaging indicates that the appliance cannot be treated as normal
domestic trash, but must be handed in at a collection point for recycling electric and electronic
appliances. Your contribution to the correct disposal of this product protects the environment. Further
information about the recycling of this product can be obtained from your local municipal authority.
Page 4
4 | P a g e
Your safety and the safety of others are very important to
To reduce the risk of fire, electrical shock or injury when using your appliance, follow these basic
us.
precautions.
SAFETY PRECAUTIONS
Before the portable air conditioner is used, it must be properly positioned and installed
as detailed in this manual.
Do not under any circumstances cut or remove the third (ground) prong from the power
cord.
Make sure this unit is connected to a correctly grounded power supply outlet. Do not use an
extension cord or power strip.
The power cord is UL listed. It has a built-in L.C.D.I. (leakage, current, detection,
interruption) circuit breaker for added safety. If the power supply is interrupted, press the
reset button to reconnect the unit to power source.
It is recommended to use a separate circuit that its size should be 15 Amps for the air
conditioner.
Do not use an excessively wet cloth, industrial solvents, oil-based products to clean this
portable air conditioner.
To avoid the risk of shock, the product should never be used in bathrooms, shower rooms,
or in any other steamy or wet areas.
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or
any other appliances.
Do not repair, disassemble and/or modify the unit by yourself.
Always turn off the portable air conditioner when cleaning the air filter, and transporting.
Do not turn this unit on and off by plugging and unplugging. Always use the ON/OFF switch.
Transport the unit in an upright position only, or leave it in an upright position for a
minimum of 4 hours before first use.
Ensure curtains or other objects are not obstructing the air inlet filters.
Do not bend or crush the exhaust hose while in use.
Always allow at least 20” of clearance around the unit for ventilation. Do not use this unit
inside closets, cabinets and/or cramped spaces between furniture.
This unit is optimized to operate in an ambient temperature of 64°F – 95°F.
This unit must be installed in an area protected from the elements, such as wind, rain,
water spray or drips.
The unit should not be placed next to ovens, grills or other heat sources.
Always place the unit on even and hard and level surface.
Do not sit or place objects on the unit.
Do not allow children to climb, stand or hang on the unit. The air conditioner could tip over
and get damaged and/or seriously injure somebody.
Page 5
5 | P a g e
Keep fingers out of the air intakes and air outlets.
MODE
ROOM TEMPERATURE
COOL
Higher than 64°F
DRY
Higher than 60°F
The unit is an electrical appliance. To avoid injury from electrical shock do not operate it with
wet hands, while standing on a wet surface or while standing in water. Do not use it in
outdoors or in wet conditions.
When positioning or moving the unit, ensure it is not turned upside down or greater than 45°
or more off level.
This unit is designed for household, non-commercial use only. Any other use will void the
warranty.
Do not plug into the power outlet before set up is completed.
Do not operate this unit without the air filter(s).
Do not use harsh chemicals to clean the filter(s). Dry thoroughly before inserting the filter(s)
into the unit.
Do not add extra length to the exhaust hose by more than a total length of 9’. This will
reduce the cooling efficiency of the portable air conditioner.
At the end of each season, all water must be drained from the unit and filter(s) must be
cleaned before storage.
THE MANUFACTURER DISCLAIMS ANY RESPONSIBILITY IF THE ABOVE INSTRUCTIONS
ARE NOT FOLLOWED.
OPERATING CONDITION
Your portable air conditioner is supplied with a Leakage-Current
Detection and Interruption (LCDI) plug. This plug reduces the risk of
fire due to arcing faults in the power supply cord. Please follow the
instructions below to ensure that LCDI plug works properly.
1. Plug the power cord to a grounded wall outlet. Do not plug to
a power strip or extension cord.
2. Press the TEST button on the plug. This should trip the plug
and cut the power to the air conditioner. If the plug does not
trip and the unit comes on, please contact technical support.
3. Press the RESET button to start the air conditioner.
4. Do NOT use the TEST and RESET buttons to turn the air
conditioner on and off.
Page 6
6 | P a g e
IDENTIFICATION OF ACCESSORIES
Note: Please visit whynter.com for optional accessories information
IMAGE
ACCESSORY NAMEQUANTITY
Intake and Exhaust
Fixture
Screws
Hose connectors4 pieces
Window slider kit
Cover
hose
2 pieces
2 pieces
8 pieces
1
set
2 pieces
Remote
Optional Intake filter (sold separately) 1 piece
Optional 3M™ Antimicrobial filter (sold
Carbon Filter
Storage Cover
control
separately)
1 piece
1 piece
1 piece
1 piece
Page 7
7 | P a g e
IDENTIFICATION OF PARTS
Front
1. Air vent
2. Control panel
Rear
3. Evaporator air intake
4. Air intake
5. Air exhaust
6. Casters
7. Drain plug
8. Power cord
9. Intake filter (sold separately)
Page 8
8 | P a g e
OPERATING YOUR AIR CONDITIONER
Power Control
Turns the unit on and off.
Timer
Turns the timer function on and off.
Warning Light
Condensation water may accumulate in the unit. If the
internal reservoir becomes full, the warning light and the
STOP light will come on and the unit will stop until the
water is drained.
Timer / Temperature Set Control
Adjusts set thermostat temperature and timer.
The display temperature is the set temperature.
NOTE: This unit is capable of displaying set temperature
in Fahrenheit or in Celsius. To convert from one to the
other, press and hold the Up and Down buttons for 3
seconds.
Mode Control
Controls the 3 function modes: COOL, DEHUMIDIFY
and Fan only.
Fan Speed Control
Controls the 3 fan speeds: High, Medium & Low.
NOTE: Unit does not need to be vented in Fan mode
Before you begin, thoroughly familiarize yourself with the control panel, remote control and all of
the functions. Follow the symbol for the desired function. The unit can be controlled by the unit
control panel alone or with the remote control.
CONTROL PANEL
Page 9
9 | P a g e
INSTALLATION INSTRUCTIONS
Location
The air conditioner should
The unit is equipped with caster wheels for portability. It should only be rolled on smooth, flat surfaces.
Use caution when rolling on carpet surfaces. Do not attempt to roll the unit over objects.
The air inlet and outlet should be free of any obstructions and be placed with at least 20” of clearance
for efficient air-conditioning and circulation.
Exhaust hose Installation
When using the air conditioner, the hot air from the exhaust hose must be exhausted out of the room to
complete the air exchange of the condenser. The intake hose is optional. When the unit is operating in
dehumidifying or fan-only mode, installation of the exhaust hose is optional.
1. Expand each end of the exhaust and intake hoses about 6”.
2. Install the hose connectors onto the exhaust and intake hoses by turning clockwise.
be placed on a hard and level surface strong enough to support its weight.
3. Align the tab cut-outs of each of the hose connectors to the tabs on the air exhaust and air intake at
the rear of the unit and snap in place.
EXHAUST
INTAKE
If installing the optional air intake hose in an area with poor air quality, we recommend
purchasing the intake hose pre-filter accessory.
Only extend the hose to the necessary length, keeping it as short and as straight as possible.
We do not recommend extending the hose more than 9' long.
If you are interested in purchasing an additional 5’ exhaust hose, please contact
support@whynter.com for retail sales information or visit whynter.com for a list of optional
accessories.
Page 10
10 | P a g e
Window kit Installation
The
window
kit
has
been
designed to fit most standard vertical and horizontal windows. However, it
may be necessary to modify the installation procedures to accommodate your window.
NOTE:
• If your window opening is smaller than the minimum length of the window slider kit, the window
slider kit can be cut to fit the window opening. Never cut into the exhaust and intake hose cut-outs on
the window slider kit.
• If your window opening is larger than the maximum length of the window slider kit, additional
material will be needed to cover the open space such as, Plexiglas, PVC plastic, ply wood, etc.
Alternately, an additional window slider kit can be purchased to be used in combination with the
included kit.
• When using the window slider kit on a window or sliding door, additional security measures may be
needed.
1. Open the window approximately 5”.
2. Adjust the length of the window slider to the same length
and width of the opening of the window. Cut the window
slider if necessary to fit the length of your window.
3. Insert the fixture through the back grooved side of the
window slider hose cut-out. Line up the fixture with the 4
screw holes and tighten the fixture with 4 screws from the
front side of the slider panel. (Fig. 1)
4. Fit the window slider kit into the window opening and close
the window to secure the window slider kit. For long term
installation, you may screw the window kit into your window
frame.
5. Move the air conditioner close to the window, extend the
hose to the necessary length, keeping it as short and as
straight as possible and attach the other end of the hose to
the window slider kit.
6. Align the tab cut-outs of the hose connector to the tabs on
the fixture and snap the hose connector to the window slider
kit.
Figure 1
Page 11
AIR FILTERS IN
Your Whynter portable air conditioner is equipped with a washable Pre-Filter and an Activated
Carbon Filter.
STALLATION
The washable Pre-Filter removes large particles such as dust, pet hair and dander.
The Activated
you replace the Activated Carbon filter every 2-3 months or as needed. Follow the steps below
to install the filters.
WARNING: NEVER OPERATE THE AIR CONDITIO
1. Pull up the
Carbon filter is designed to remove smoke and other odors. It is recommended
NER WITHOUT THE PRE-FILTER
pre-filter frame
2. Remove the
3. Place the Activated Carbon filter on the Pre-Filter.
4. Reattach the filter frame.
5. Insert the assembled filter frame into the unit.
An optional 3M™ Antimicrobial Filter can also be purchased to replace the activated carbon filter. The 3M™
Antimicrobial Filter has an antimicrobial agent helps inhibit the growth of mold and mildew on the filter. This
filter is electrostatically charged for enhanced particle capture and retention.
**If you are interested in purchasing optional accessories, please contact support@whynter.com for retail
sales information.
Pre-Filter from the filter frame.
: The optional 3M™ Antimicrobial Filter is not washable and should be replaced every 3 months.
Note
11 | P a g e
Page 12
OPERATION
BEFORE USING YOUR PORTABLE AIR CONDITIONER
Remove the exterior and interior packaging
Before connecting the appliance to a power source and operating, let the unit stand upright for a
minimum of 4 hours. This will reduce the possibility of a malfunction in the cooling system from handling
during transportation
INSTRUCTIONS
SWITCHING ON/OFF THE AIR CONDITIO
The unit can be switched ON or OFF by
button on the remote control.
COO
LING MODE
In this mode, the air conditioner cools and dehumidifies the room. To activate the cooling function,
press the Mode Control button until the indicator illuminates. When cooling mode is set, the
compressor will start in approximately 3 minutes.
NOTE: In cooling mode, hot air is exhausted from the outdoor exhaust port and the exhaust hose must
be connected to exhaust out the hot air.
The temperature setting range of this air conditioner is from 61°F to 89°F. To set the temperature,
press the + or - buttons. This air conditioner has a 5°F temperature cushion; if the set temperature is
within 5°F of the ambient temperature, the unit runs in fan only mode. This saves energy and prolongs
the life of the compressor of the air conditioner. Once the set temperature is achieved, the compressor
will turn off and the fan runs continuously to circulate the air within the room.
To set the fan speed, press the Fan Speed button.
Note: When the compressor is running, the sound difference between each fan speed is not very
noticeable.
DEHUMIDIFYING MODE
In this mode, the air conditioner dehumidifies the room, the compressor will activate intermittently
depending on the ambient temperature and the fan speed is set to Low.
To activate dehumidifying mode, press the Mode Control button until the indicator illuminates.
When switching between functions, there will be an approximate 3 minute transition time.
In dehumidifying mode, the exhaust hose does not need to be vented. If the exhaust hose is vented,
the room will be cooled as it dehumidifies. To prevent cooling, remove the exhaust hose from the
window kit and allow the warm air from the rear to be re-circulated into the room. If room temperature
is higher than 77°F, the fan speed can be adjusted. If room temperature is lower than 77°F, the fan
speed is set at Low.
NER
pressing
the
Po
wer
bu
on the control panel or the Power
tton
Note:
When using dehumidifying mode, venting the exhaust hose to the outside is not required. If vented,
the warm air is exhausted to the outside and cooling within the room may occur. Additionally, if the
exhaust hose is not vented, the unit may require more frequent draining.
The air conditioner does not have a humidistat in which a specific humidity level can be set.
FAN ONLY MODE
In this mode, only the fan of the air conditioner runs and circulates the air within the room. To activate
fan only mode, press the Mode Control button until the indicator illuminates. In this mode, the
temperature cannot be set. Subsequently, set the desired fan speed by pressing the Fan Speed button.
Note: When using fan only mode, venting the exhaust hose to the outside is not required.
12 | P a g e
Page 13
TIMER (DELAYED SWITCH ON / OFF) FUNCTION
This function mode enables
a delayed switch ON or delayed switch OFF of the air
conditioner. The time (hours) delay can be set, enabled and disabled. The timer is
adjustable between 1-24 hours.
SETTING SWITCH OFF TIMER
With the air conditioner operating in any function mode, press the Timer Control button. Then set
the desired time delay OFF hours by pressing the + or - buttons. When the delay time set has
elapsed, the air conditioner switches off.
SETTING DELAYED SWITCH ON TIMER
With the air conditioner is off, press the Timer Control button. Then set the desired time delay ON
hours by pressing the + or - buttons. When the delay time set has elapsed, the air conditioner
switches on.
AUTO RESTART
In the event of a power outage, the air conditioner restarts at the previously set function mode and
settings when power is restored.
NOISE LEVEL
Portable air conditioners may make sounds that are not familiar to you. The sounds listed below are
normal. Noise reflecting off
hard surfaces such as a floor or wall can make the sounds seem louder
than they actually are.
The compressor may make a pulsating or high-pitched sound.
Water running from the evaporator to the water tank may make a splashing sound.
Refrigerant flowing may make a gurgling sound.
Fan sound may come from front and back air vents.
COMPRESSOR LOCK OUT
This portable air conditioner is optimized to operate in an ambient temperature of 64°F – 90°F. The
compressor circuit has an automatic 3 minute time delayed start if the unit is turned off and on quickly.
This prevents over-heating of the compressor and possible circuit breaker tripping.
WATER DRAINAGE
The air conditioner has the capacity to dehumidify up to 101 pints per day. The patented selfevaporating function of the unit fully exhausts all condensation automatically in most environments
when humidity is less than 70%. Areas with more than 70% humidity, the self-evaporating function can
still exhaust about 98% of the moisture and the remaining 2% of moisture will be collected in the water
tank of the air conditioner. When there is excess water condensation inside the unit, the air conditioner
stops running and the RED Stop light illuminates. The Stop light indicates that the water condensation
needs to be drained manually:
Manual Drain:
1. Turn off the unit.
2. Carefully roll the unit to a drain location or position a flat container, dish or optional drain bucket
accessory (sold separately) under the drain area of the lower drain port.
3. Remove the drain cover and rubber plug and the condensed water will drain out automatically.
4. Once all the condensed water is drained, replace the drain rubber plug and cover into the drain firmly.
Page 14
14 | P a g e
Note: Please contact support@whynter.com for retail sales information or visit whynter.com for a
list of optional accessories
REMOTE CONTROL
The portable air conditioner can be switched on by the remote control.
NOTE:
Other appliances in the same room controlled by a remote control (TV, radio, stereo, etc.), may
cause interferences.
Electronic and fluorescent lamps may interfere with the signal transmissions between the remote
control and the air conditioner.
Remove the batteries if the remote control is not used for long periods.
INSTALL ING BATTERIES
Only use two AAA 1.5V Batteries in the remote control.
Alway s change both batteries at the same time.
To insert the
adhere t o the polarity signs on the bottom of the battery housing, close the flap once the batteries
have been inserted.
batteries, open the flap on the back of the remote control by sliding if off. Strictly
Page 15
15 | P a g e
CARE AND MAINTENANCE
IMPORTANT:
Switch off the air conditioner and disconnect the plug from the power outlet
Drain al collected condensation from the upper and lower drain ports.
Only transport the air conditioner in an upright position.
CLEANING THE PRE-FILTER
This unit includes two air filters; a washable pre-filter and an activated carbon filter.
To ensure the air intake is filtered properly and to assure that your air conditioner runs efficiently, it is
recommended that the pre-filter is washed at least once every two weeks depending on use.
1. Switch off the air conditioner.
2. Pull the pre-filter frame from the unit.
3. Remove the activated carbon filter from the pre-filter.
4. Use a vacuum cleaner or tap lightly to remove loose dust and dirt from the pre-filter.
5. Rinse the pre-filter thoroughly under warm running water (no hotter than 100F.)
6. Dry thoroughly before re-inserting the filters.
NOTE: The activated carbon filter and 3M™ Antimicrobial Filter are not washable. They are optional
filters and should be replaced every 2-3 months or as needed if used.
Please contact support@whynter.com for retail sales information or visit whynter.com for a list of
optional accessories
WARNING! Never operate the air conditioner without the pre-filter in place
CLEANING THE AIR CONDITIONER
Always switch off the air conditioner and disconnect the plug from the power
before cleaning the air conditioner.
Use a soft damp cloth to wipe the body of the unit.
Never use harsh chemicals, oil
other cleaning solutions. These
END OF SEASON STORAGE
This portable air conditioner comes with one end of season storage cover. We highly recommend
that storage cover bag is utilized when the unit is not going to be used for a period of time.
WARNING: To avoid danger of suffocation, keep this bag away from babies and children.
Switch off the air conditioner and disconnect the power plug from the power supply outlet before
cleaning the air conditioner.
Clean the pre-filter.
Drain the condensed water completely.
On a warm day, set the unit to Fan only mode for half a day to dry the unit internally.
Gather the power cord and bundle it.
Remove the batteries from the remote.
If leaving the window kit in place, disconnect the exhaust and intake hose from the window
slider kit and place the included covers on the fixtures. Otherwise, remove the window kit from
the window opening. To remove the hose connectors from the fixtures on the window kit, slightly
turn, push and gently pull the connector to release.
Place the storage cover over the air conditioner.
-based products, detergents, chemically treated cloths or
could possibly damage the body of the air conditioner.
supply outlet
Note: Depending on use, it is recommended that the air conditioner be cleaned internally annually.
Please contact Whynter at support@whynter.com for internal maintenance cleaning instructions.
15 | P a
g e
Page 16
TIPS:
1. Keep the exhaust hose as short and straight as possible
The exhaust hose removes heat from the room. It should remain as short and straight as possible
without sharp bends or twists to maximize efficiency. If the exhaust hose must be extended, do not
exceed 9’.
2. Turn the air conditioner on early
Turning the air conditioner on early instead of waiting until the hottest point of the day will allow the
unit to be more effective. The air conditioner will not have to work as hard to cool the room down and
maintain the set temperature.
3. Reduce heat sources
Direct sunlight, televisions, computers and other heat generating appliances work against the air
conditioner by introducing heat into the space.
• Close window curtains and blinds to keep direct sunlight out
• Close doors and windows
• Keep ovens and stoves off
• Turn off unused lights
• Add weather stripping around windows and doors
4. Keep the air filter clean
Regular cleaning will help keep your air conditioner working properly. Dusty filters and vents greatly
reduce the airflow and efficiency of the unit.
• Clean the washable pre-filter regularly
• Replace the activated carbon filter every 2-3 weeks depending on use
• Vacuum any accumulated dust from around all vents
TECHNICAL DATA
ModelARC-141BG
Cooling capacity14,000 BTU
Power supply115v/ 60Hz
Maximum power input1250 Watts
Maximum input10.8 Amps
Dehumidifying capacity101 Pts / Day
Thermostat61°F to 89°F
RefrigerantR-410A
Air flow (max.)360 m3/ Hour
Fan speeds3 (H, M, L)
Unit Dimensions19” W x 16” D x 35.5” H
Unit Weight80 lbs
16 | P a g e
Page 17
17 | P a g e
TROUBLESHOOTING
Problem
Possible Causes
Solutions
The portable air
conditioner does not
turn on
Power failure / outage.
The automatic switch, line
fuse, or breaker has been
tripped.
The power supply voltage is
too low.
The power cord is damaged.
The L.C.D.I. power plug for
the unit is tripped.
The internal water reservoir
is full.
Possible loose connection
Internal fuse has blown
Restore the power supply.
Flip the switch / change the fuse / turn the breaker
back on. Also note that you may have too many
appliances drawing power on one circuit, you may
need to move the other appliances to another
circuit.
Move the unit onto another circuit with the correct
voltage.
Contact Whynter Service Department. Only
authorized personnel should replace damaged
power cord or power plug.
Press the Reset button on the L.C.D.I. power plug.
Drain water from the air conditioner.
Contact Whynter Service Department
The unit turns on but
the compressor does
not turn on (the fan
runs but the unit is not
cooling)
The room temperature is
outside of the operational
tolerances of the unit.
The Cooling mode is not on.
The compressor has not
turned on yet because of its
time delay.
The set temperature is too
high.
The internal water reservoir
is full.
This unit is designed to work in ambient
temperatures of 64°F to 95°F.
Press the MODE button until the COOL light is
shown on the display.
Give the compressor 3 minutes to turn on after the
Cooling mode has been selected.
Set the air conditioner to a lower temperature. It is
recommended to set the temperature to at least
5°F of the ambient temperature.
Either manually drain the water by removing the
drain plug or allow the unit to exhaust the water
itself by running the fan only mode. Then cooling
will resume.
Page 18
18 | P a g e
The air coming out of
the unit is not very
cold, or the airflow
volume is weak
The filters are dirty or
obstructed.
The air intake or exhaust is
obstructed.
The unit is set in DRY or
FAN mode.
The unit is set to low fan
speed.
Clean the air filters.
Make sure there is at least 20" of clearance from
the air intake. Make the length of the exhaust hose
is as short as possible.
Set the unit to the cooling mode.
Set the unit to a higher fan speed.
The unit has worked for
a long time, but the
room is not cold
enough
Windows or doors are open.
There are too many people
in the room.
There is direct sunshine into
the room.
The room is a kitchen or
with many heat-producing
appliances
There is a server in the
room.
The room is too large.
Close all windows and doors.
You may need additional cooling or another air
conditioner.
Close curtains or blinds and try to minimize the
amount of direct sunlight into the room.
You may need additional cooling or another air
conditioner.
You may need additional cooling or another air
conditioner.
You may need additional cooling or another air
conditioner.
The unit is very noisy
The unit is not level.
The surface underneath the
unit is uneven.
Low power voltage.
Make sure the unit is on hard, level and stable
surface.
Move the unit to a location with a level and hard
floor.
Make sure the wall outlet and support the required
power consumption of the air conditioner and do
not use an extension cord.
The unit leaks water
The unit is tilted or not
leveled
The water tank is full.
Make use the unit is leveled.
Drain water from the drain plug at the back of the
air conditioner.
The unit needs to be
drained too often
The humidity in the area
may very high
Possible loose connection
Remove the intake hose if the outside humidity is
high or it is raining
Contact Whynter Service Department
Fan speed cannot be
changed
Fan speed differences are
not very noticeable
The fan speed difference is not very noticeable
when the compressor is on. Try setting the unit to
Fan only mode, you should be able to hear the
difference between high and low fan speed
settings.
Page 19
ONE YEAR LIMITED WARRANTY &
THREE YEAR WARRANTY ON COMPRESSOR
This WHYNTER portable air conditioner is warranted, to the original owner within the 48
ental states, for one year from the date of purchase against defects in material and
contin
workmanship under normal use and service. Should your WHYNTER portable air conditioner
prove defective within one year from the date of purchase, return the defective part or unit,
freight prepaid (within two months of purchase; after two months to one year, customer will be
responsible for freight cost to Whynter’s service department), along with an explanation of the
claim to Whynter LLC. Please package the portable air conditioner carefully in its original
packaging material to avoid damage in transit. Please retain the original box and packaging
material. Under this warranty, Whynter will repair or replace any parts found defective. This
warranty is not transferable. After the expiration of the warranty, the cost of labor and parts will
be the responsibility of the original owner of the unit.
THIS WARRANTY DOES NOT COVER:
• Acts of God, such as fire, flood, hurricanes, earthquakes and tornadoes.
• Improper power supply such as power surge, low voltage, defective household wiring or inadequate fuses.
• Use in commercial or industrial applications
• Damage, accidental or otherwise, to the portable air conditioner while in the possession of a consumer not
caused by a defect in material or workmanship;
• Damage caused by consumer misuse, tampering, or failure to follow the care and special handling provisions
in the instructions.
• Damage to the finish of the case, or other appearance parts caused by wear.
• Damage caused by repairs or alterations to the product by anyone other than authorized by the manufacturer.
• Removal, Replacement Packaging, Freight and Insurance cost for the warranty service.
DISCLAIMER OF IMPLIED WARRANTIES
CUSTOMER'S SOLE AND EXCLUSIVE REMEDY UNDER THIS LIMITED WARRANTY SHALL BE PRODUCT REPAIR
OR REPLACEMENT AS PROVIDED HEREIN. CLAIMS BASED ON IMPLIED WARRANTIES, INCLUDING
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED TO ONE YEAR
OR THE SHORTEST PERIOD ALLOWED BY LAW, BUT NOT LESS THAN ONE YEAR. WHYNTER SHALL NOT BE LIABLE
FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SUCH AS PROPERTY DAMAGE AND INCIDENTAL EXPENSES
RESULTING FROM ANY BREACH OF THIS WRITTEN LIMITED WARRANTY OR ANY IMPLIED WARRANTY. SOME
STATES AND PROVINCES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSE- QUENTIAL
DAMAGES, OR LIMITATIONS ON THE DURATION OF IMPLIED WARRANTIES, SO THESE LIMITATIONS OR
EXCLUSIONS MAY NOT APPLY TO YOU. THIS WRITTEN WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS. YOU MAY
ALSO HAVE OTHER RIGHTS THAT VARY FROM STATE TO STATE.
; LIMITATION OF REMEDIES
Please retain the original proof of purchase in order to obtain warranty services.
Warranty begins from the original date of purchase.
To obtain service or information, contact Please retain the original proof of purchase in
order to obtain warranty services.
Warranty begins from the original date of purchase.
To obtain service or information, contact
Whynter LLC via email at support@whynter.com or call
866-WHYNTER.
Product contents and specifications may change without notice.