White-Westinghouse SWX703HS0, SWS1233HS1, SWS1339HQ0, SWS1339HS0, SWS833HQ0 Installation Guide

...
Installation
Instructions
[::_ii_i,,_!!_[_:ii!i__i_!!i!!iii_i__:iil_211_i!!!i_!!!,_,_,fi!_iiii!__ii_i:,_!_"ii!!!i:,C_iCi!ii_;ii_',,i_i_iiii__ii_!:i'i_i!_,_i_iiiiill_!_i_,i_!iii_ii,_i_!_i!ii!_,:!_i_i:_,_i_ii_:_?,:_!i!!ii!?,_i....
instrucciones
para la instaladOn
Before beginning installation, carefully read these instructions. This will simplify the installation and ensure the washer is installed correctly and safely. Leave these instructions near the washer
after installation for future reference.
Antes de comenzar la instalacion, lea estas instrucciones co atencion. Le facilitaran la instalacion y asegurar_n que la lavadora sea instalada correctamente y de manera segura. Guarde
estas intstrucciones cerca de Ioa lavadora una yes terminada la instalacion para
referirse a elias en et futuro.
NOTA: el suminstro electro de su lavadora debe estar conforme con los codigos y
ordenanzas locales y la edicion mas reciente del Codigo Etectrico Nacionat ( National Electrical Code), ANSI/NFPA 70.
Contents
SUBJECT PAGE
Pre-lnstallation Requirements 2
Electrical Requirements 2 Grounding Requirements 2 Water Supply Requirements 2
Drain Requirements 2
Rough-In Dimensions 2
Location 2
Unpacking 2-3
Installation 3
Replacement Parts 3
Requisitos antesde la instalaciOn 4
Requisitoselectricos 4
Requisitos para latoma de tierra 4
Requisitos para elsuministro de agua 4
Requisitos para el drenaje 4
Dimensiones para lainstalaci6n 5
Ubicacion desu hvadora 5
Desempaque 5
Instalacion 5-6
Piezasde repuesto 6
Printed in U.S.A. P/N I34771300 (0608)
PRE-INSTALLATION REQUIREMENTS
Tools Required for Installation:
1.
3/8 in. socket wkh ratchet.
2.
Channel-lock adjustable pliers.
3.
Carpenter's level.
ELECTRICAL REQUIREMENTS
CIRCUIT- Individual, properly polarized and grounded 15amp. branch
circuit fused with 15 amp. time delay fuse or circuit breaker. POWER SUPPLY - 2wire, with ground, 120 volt, single phase, 60 Hz,
Alternating Current.
OUTLETRECEPTACLE - Properly grounded 3-prong receptacle to be located so the power supply cord isaccessible when the washer is in
an installed position.
GROUNDING REQUIREMENTS
conductor can result in a risk of electrical shock. Check with a licensed electrician if you are in doubt as to whether the appliance is properly
grounded.
1. The washer MUSTbe grounded. Inthe event of a malfunction or breakdown, grounding will reduce the risk of electrical shock by
a path of least resistance for electrical current.
2. Since your washer is equipped with a power supply cord having an equipment-grounding conductor and a grounding plug, the plug MUST be plugged into an appropriate, copper wired
receptacle that is properly installed and grounded in accordance with all local codes and ordinances or in the absence of local
codes, with the NationalEbctricalCodes,jq if DOnot, under -_ ANSI/NFPA 70 (latest edition). If in _ _i_tances, ::
doubt, call a licensed electrician. I /17 J or bypassthe DO NOT cut off or alter the 2r_u2_!2gP!_2g:_J
grounding prong on the power supply cord. In situations where a --1t1_1_
two-slot receptacle is present, it is _lw the owner's responsi- Powersupply _
..... cord with 3" tong
blhty to have a hcensed electnclan g_oundingp_u*g_g
replace it with a properly grounded three prong grounding
type receptacle.
3. For added personal safety, connect a separate ground wire (No.
18 minimum) from a top panel hinge screw on the rear of the
washer to a grounded cold water pipe. DO NOTground to a gas supply pipe or hot water pipe.
4. Grounded cold water pipe MUSThave metal continuity to electrical ground and MUST register no more than 25 ohms resistance. It
MUST not be interrupted by plastic, rubber, or other electrical
insulating connectors such as hoses, fittings, washers, gaskets
(including water meter or pump). Any electrically insulated connector should be jumped with a length of No. 4 copper wire securely clamped to bare metal at both ends with a UL approved
ground clamp.
5.
If a grounded water pipe is not available, a ground rod MUSTbe used and register no more than 25 ohms resistance when in the
ground. Drive the rod into the ground outside the dwefling and
connect a grounding wire (12 AWG or heavier) between the
grounding screw and the grounding rod. It may take more than
one ground rod to not exceed 25 ohms resistance to ground.
improper connection of the equipment grounding
WATER SUPPLY REQUIREMENTS
Hot and cold water faucets MUST be installed within 42 inches (107 cm) of your washer's water inlet. The faucets MUST be 3/4 inch (1.9 2. cm) garden hose type so inlet hoses can be connected. Water pressure
MUST be between 10 and 120 pounds per square inch (maximum 3.
unbalance pressure, hot vs. cold, 10 psi.) Your water department can 4. advise you of your water pressure. The hot water temperature should 5.
be about 140 degrees F(60 degrees C). 6.
2
DRAIN REQUIREMENTS
1.
Drain capable of eliminating 17 gallons (64.3 L) per minute.
2.
A standpipe diameter of 1-1/4 in. (3.18 cm) minimum.
3.
The standpipe height above the floor should be:
Minimum height: 33 in. (61 cm) Maximum height: 96 in. (244 cm)
--T--
_, 96" Max.
33" Min. (244 cm) (61 crn)
.L __£__
NOTE: For installations requiring a longer drain hose, have a qualified technician install a longer drain hose according to your model number. For drain systems in the floor, install a syphon break kit, P/N 5377678100. Both parts are available from an authorized parts distributor.
ROUGH-IN DIMENSIONS
VVA_ER _ 51"
NLEfS<J_' 1129.S4
(REAR)
,,
, OUTLET 29-7/16" (11
I_ 3-3/4"
,J REAR I I
' (9.s3c_)
27"_
(68.58cm)
FRONT VIEW
(74.77cm) c
OUTLETS'/_ "_L
I _ I _
27"_
(6&58cm)
SIDE VIEW
LOCATION OF YOUR WASHER
DO NOT INSTALL YOUR WASHER:
1. In an area exposed to dripping water or outside weather conditions. The ambient temperature should never be below 60
degrees F(15.6 degrees C) for proper washer operation.
2. In an area where it will come in contact with curtains or drapes.
3. In an area (garage or garage-type building) where gasoline of other flammables are kept or stored (including automobiles).
4. On carpet. Floor MUSTBE SOLID with a maximum slope of 1in. (2.54 cm). To ensure vibration or movement does not occur,
REINFORCEMENT of the floor may be necessary.
IMPORTANT MINIMUM INSTALLATION CLEARANCES
When installed in alcove: Sides= 0" (0 cm),
Rear= 0" (0 cm), Top = 20" (50.8 cm).
When installed in closet: Sides= 0" (0 cm),
Rear= 0" (0 cm), Top = 20" (50.8 cm), Front = 1"(2.54 cm). Closet door ventilation openings required: 2 louvers each 60 square inches (387 cm 2) 3 inches (7.6 cm) from bottom and top of door.
UNPACKING
1. Using the four shipping carton corner posts (two on each side), carefully lay the washer on its left side and remove foam shipping
base. Using aratchet with 3/8" socket, remove the mechanism shipping
bolt and plastic spacer block from the center of the base. Return the washer to an upright position. Remove the tape holding the lid shut and open the lid. Remove the foam tub blocking pad. Remove the inlet hoses (some models have inlet hoses already attached to the water valve) and enclosure package from the tub.
11-7/I6"
Loading...
+ 4 hidden pages