White Rodgers F92-1011 User Manual

F92-1011
Regulated L.P. to Natural Gas
Conversion Kit for 36G/36J Two-Stage
INSTALLATION INSTRUCTIONS
Installer: Save these instructions for future use!
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE.
WARNING
!
This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly, a fire, explo­sion, or production of carbon monoxide may result, causing property damage, personal injury, or loss of life. The qualified service agency performing the work assumes the responsibility for the proper conversion of this appliance with this kit.
APPLICATION
This conversion kit allows the 36G Series and 36J Series Two­Stage gas valves to be used on Natural gas applications. This
conversion kit is for use on all 36G/36J Two-Stage, fast and slow open models.
High
Regulator
Cover Screw
Plastic Regulator
Adjustment Screw
Low
TO CONVERT FROM L.P. TO NATURAL GAS
1. Remove both regulator cover screws.
2. Remove both regulator adjustment screws (beneath the cover screws).
3. Remove both regulator springs from regulator sleeves. (L.P. configuration may be two L.P. springs, color-coded white, or one L.P., color-coded white, and one Natural, color-coded silver/plain).
4. Insert the Natural Gas regulator springs (provided in the conversion kit and color-coded silver/plain) into the regulator sleeves.
5. Replace the High regulator adjustment screw and adjust approximately 14 turns from top of sleeve.
6. Replace the Low regulator adjustment screw and adjust approximately 10 turns from top of sleeve.
7. Adjust both outlet pressures to the appliance manufacturer's requirements.
8. Replace both regulator cover screws.
9. Remove the L.P. WARNING label, if present, from the gas valve. Also attach the small round NAT GAS labels to the top of the regulator cover screws.
!
WARNING
VALVE CONVERTED FOR USE ON L.P. GAS. IMPROPER OPERATION COULD RESULT IN DEATH OR SERIOUS INJURY.
!
MISE EN GARDE
SOUPAPE CONVERTIE POUR USAGE SUR GAZ DE PÉTROLE LIQUÉFIÉ. UN FONCTIONNEMENT INAPPROPRIÉ PEUT PROVOQUER LA MORT OU DES BLESSURES GRAVES.
WARNING Label
Regulator Spring
Figure 1. 36G/36J 2-Stage models
White-Rodgers is a division
of Emerson Electric Co.
www.white-rodgers.com
Natural Gas Regulator
Springs (silver/plain)
NAT.
NAT.
GAS
GAS
Natural Gas Labels
Figure 2. Contents of kit
PART NO. 37-6586B
Replaces 37-6586A
1005