Single-Stage/HSI Integrated
Furnace Control Kit
OEM Replacement
21D83M-843
Nitride Ignition
Integrated Furnace Control
Controls Gas Valve, Ignitor, Blower, Inducer,
Humidifier and Air Cleaner. Replaces Lennox models.
Kit includes:
1 – 50A66-843 Ignition Control Board
1 – Wiring harness (9-pin to 12-pin)
1 – Wiring harness (4-pin to 6-pin)
1 – Mounting panel
4 – Stand-off fasteners
1 – Circuit breaker
1 – 4" blue wire
2 – Wiring diagrams
Replace
the Original
with the Original.
21D83M-843 simplifies installation and ensures
peak system performance.
Features:
• Includes diagnostic indicator flash codes
• 3 fan speeds
• Remote flame sense
• Humidifier and electronic air cleaner connections (optional)
Integrated Furnace
Control – 21D83M-843

Single-Stage
OEM
HSI Integrated
Furnace Control Kit
Nitride Ignition Integrated Furnace Control
Controls Gas Valve, Ignitor, Blower, Inducer, Humidifier and Air Cleaner. Replaces Lennox models.
Specifications
Input Voltage: 25 VAC 50 / 60 Hz
Maximum Input Current @ 25 VAC: 0.45 amp
Valve Relay: 1.5 amp @ 25 VAC 50 / 60 Hz 0.6 pf
Ignitor Relay: 2.0 amp @ 120 VAC 50 / 60 Hz (resistive)
Inducer Relay: 2.2 FLA – 3.5 LRA @ 120 VAC
Circulator Relay: 14.5 FLA – 25.0 LRA @ 120 VAC
Operating Temperature Range: -40 to +175°F (-40 to +79°C)
Humidity Range: 5% to 93% relative humidity (non-condensing)
21D83M-843 Cross Reference
21D83M-843 Replaces:
Lennox White-Rodgers
10M9301
12L6901
32M8801
56L8401
24L8501
63K8901
97L4801
100925-01
100925-03
17W9201
23W5101
30W2501
69M0801
69M1501
83M00
50A65-120
50A65-121
50A62-120
50A62-121
50A62-820
21D83M-843
50A66-122
50A66-123
Timing Specifications
(All times are in seconds unless noted otherwise)
21D83M-843
Pre-purge: 15
Heat delay to fan ON 45
Heat delay to fan OFF 60/90/120/180
Cool delay to fan ON 2
Cool delay to fan OFF 2/45
Auto reset 60 minutes
HOT
(LINE)
HUMIDIFIER
ELECTRONIC
AIR CLEANER
FLAME
SENSOR
PROBE
LEGEND
Low Voltage (24 VAC)
Line Voltage (120 VAC)
N. C. = Normally closed switch
N. O. = Normally open switch
Replacement
21D83M-843
TYPICAL SYSTEM WIRING DIAGRAM
120 VAC
24 VAC
TH TR
50A66
FAN
COOL
HEAT
PARK
PARK
LINE
XFMR
EAC
HUM
PARK
IND
IGN
IGN N
IND N
120 VOLT
NEUTRAL
Y
W
G
24 V
HUMIDIFIER
R
C
24 V HUM
FP
PS
HLI
HLO
RO1
GND
RO2
MV
MV
TR
TH
(E2)
(E33)
24 VAC CLASS II
TRANSFORMER
INDUCER
IGNITOR
Y
W
G
R
THERMOSTAT
PRESSURE SWITCH (N. O.)
HIGH LIMIT
(N. C.)
ROLLOUT
(N. C.)
CIRCULATOR
BLOWER
COMPRESSOR
CONTACTOR
AUX. HIGH
LIMIT (N. C.)
GAS
VALVE
NEUTRAL
(LINE)
Saint Louis, Missouri Markham, Ontario
314-553-3600 905-948-3411
www.white-rodgers.com
www.emersonclimate.com
The Emerson logo is a trademark and
a service mark of Emerson Electric Co.
WR-8273