vapors and liquids in the vicinity of this or any
other appliance.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use
any phone in your building.
• Immediately call your gas supplier from neighbor’s phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the
re department.
– Installation and service must be performed by
a qualied installer, service agency or the gas
supplier.
Log sets comply with ANSI Z21.11.2 Unvented
Heaters and also comply with ANSI Z21.60
Decorative Vented Appliances for Solid Fuel
Burning Fireplaces. State or local codes may only
allow operation of log sets in a vented conguration.
Check your state or local codes.
WARNING: If not installed, operated and maintained in accordance with the manufacturer's
instructions, this product could expose you to
substances in fuel or from fuel combustion which
can cause death or serious illness.
Page 1
TABLE OF CONTENTS
Section Page
Important Installation Guidelines ....................................................................................................................3
General Information.........................................................................................................................................3
Requirements for Canada ................................................................................................................................4
Parts List & Parts View ....................................................................................................................................9
Master Parts Distributor List .........................................................................................................................10
How to Order Repair Parts ............................................................................................................................10
Service Notes .................................................................................................................................................11
25736-0-0309Page 2
IMPORTANT INSTALLATION GUIDELINES
Proper Log Placement
Log placement is critical to proper burner performance. Logs must
be correctly positioned onto the burner. The photos in this manual
show the proper pinned position for logs on this set. Owners need
to be shown proper log placement and instructed not to move the
logs.
Logs must t rmly onto the burner when positioned as shown in
the photos. Misformed logs or logs with sloppy pin holes must be
replaced.
Proper Placement of Rock Wool and Decorative Lava Rock
Rock wool can be added to burners for a glowing ember effect.
It must be positioned only on the front portion of the burner. The
photos in this manual show the proper placement of rock wool.
Decorative lava rock or small wood pieces should never be placed
on the burner. These items are only for placement on the oor of
the replace or rebox.
Proper Primary Airow into Burner
For proper burner operation and ame appearance, the ow of
primary air into the venturi tube, located on the rear of the burner,
must not be reduced. This ow of air is reduced if dirt, lint or other
obstructions build-up around or inside the venturi. Any obstruction
in the venturi tube area must be removed. The ow of air into the
venturi is also reduced if the gas orice isn’t centered in the venturi
inlet and/or is not aligned with the venturi. Any misalignment of the
burner orice may be corrected by bending the shutter cap holding
the orice to the inlet of the venturi tube.
Ceiling Fans, Portable Fans or Logs Installed Near Cold Air
Returns
Ceiling fans or oscillating oor type fans need to be monitored
during the operation of vent-free logs. If the air blows directly
into the ame causing it to impinge on the log set, or rebox, it
should be turned off or redirected. Ceiling fans could be reversed
to possibly eliminate ame impingement, and the oor fan could
be redirected. Upon installation, be aware of any cold air returns
or vents in the proximity of the log set. Any draft created around
a vent-free log set can cause the ame to impinge on the log and
create a sooting situation.
WARNING: Do not allow fans to blow directly into the replace.
Avoid any drafts that alter burner ame patterns.
WARNING: Do not use a blower insert, heat exchanger insert or
other accessory not approved for use with this heater.
Candles
Avoid the use of scented or decorative candles while the log set is in
operation. Candles produce a residue in the air that creates a soot like
substance. Burning candles while the log set is operating magnies
the problem. It should be noted that candles, in general, produce
soot. The amount of time burned and the quantity of candles burned
will determine the amount of soot produced and deposited.
Make Owners Aware of Proper Log Set Operation
Properly installed and properly maintained log sets do not deposit
soot on the logs. If users see soot appear on a log, call for service.
Do not continue to operate the log set.
Sunken Fireplace
If installing this unit into a sunken replace, you must raise the
oor to insure adequate airow and guard against sooting. Raise
replace oor using a non-combustible material, which is secure.
Glass Doors
Make sure that glass doors are open during all operations of the
logset. The opening of the glass door frame should be the dimension
used for the minimum front opening of the rebox.
Woodburning Fireplaces
The interior of the rebox and the chimney should be cleaned and
free of all creosote before installing a gas burning log set. Creosote
will soften when heated and can drop on the logset causing odors
and possibly sooting.
WARNING: Before installing in a solid-fuel burning replace, the
chimney ue and rebox must be cleaned of soot, creosote, ashes
and loose paint by a qualied chimney cleaner.
GENERAL INFORMATION
Qualied Installing Agency
Installation and replacement of gas piping, gas utilization equipment or accessories and repair and servicing of equipment shall
be performed only by a qualied agency. The term "qualied
agency" means any individual, rm, corporation, or company
that either in person or through a representative is engaged in and
is responsible for (a) the installation, testing, or replacement of
gas piping or (b) the connection, installation, testing, repair, or
servicing of equipment; that is experienced in such work; that is
familiar with all precautions required, and that has complied with
all the requirements of the authority having jurisdiction.
The installation must conform with local codes or, in the absence
of local codes, with the National Fuel Gas Code, ANSI Z223.1/
NFPA54.*
*Available from the American National Standards Institute, Inc. 11 West 42nd
St., New York, N.Y. 10018.
25736-0-0309Page 3
State of Massachusetts: The installation must be made by a
licensed plumber or gas tter in the Commonwealth of Massachusetts.
Sellers of unvented propane or natural gas-red supplemental
room heaters shall provide to each purchaser a copy of 527
CMR 30 upon sale of the unit.
REQUIREMENTS FOR CANADA
This unit cannot be installed in a UNVENTED application, this
unit can only be installed as a VENTED application with these
requirements.
IMPORTANT SAFETY INFORMATION
This unit complies with ANSI Z21.60and CGA 2.26 Decorative
Gas Appliances For Installation In Solid Fuel Burning Fireplaces.
Do not burn wood or solid fuels in a replace where a decorative
gas log set is installed. This appliance is for installation only in
a solid fuel burning replace, masonry replace or manufactured
replace.
Warning: Any modication to this gas log set or to controls can
be dangerous. Improper installation or use of the gas log set can
cause serious injury or death from re, burns, explosion or carbon
monoxide poisoning.
1. Please follow all local codes regarding installation, combus-
tion and ventilation air or in the absence of local codes follow
the National Fuel Gas Code ANSI Z223.1(U.S. installation),
or CAN/CGA-B149, Installation Code (Canada installation).
2. Proper installation, burner pan location and log placement is
important to achieve optimum look and performance of your
gas log set. The logs have been designed for easy location
and placement on the grate and must be followed for proper
operation.
3. Do not operate this log set with glass doors in the closed po-
sition. A replace screen must be in place when the log set
is burning. Adequate combustion air must be provided for
proper venting. All ames should go up and out the top of the
rebox into the ue vent. If any ames oat or curl forward
into the room do not operate appliance. Check for an open
ue and adequate combustion air into the room. A damper
clamp must be installed on the rebox damper to maintain
an open ue vent condition. Refer to page replace owners
manual INSTALLING DAMPER CLAMP section.
4. Young children must be carefully supervised when they are
in the same room as the gas log while in operation. Do not
place stockings, clothing or any ammable material above or
near the replace.
5. Do not substitute or use materials other than those supplied
for use with the log set.
6. Also refer to IMPORTANT SAFETY INFORMATION in
the replace Owner's Manual.
WARNING; DO NOT OPERATE THIS GAS LOG SET
WITH GLASS DOORS CLOSED
• Clothing or other ammable material should not be placed on
or near the appliance.
• Do not place trash or other articles on the log set during operation.
• During manufacturing, fabricating and shipping, various
components of this appliance are treated with certain oils,
lms or bonding agents. These bonding agents are not harm-
ful but may produce annoying smoke and smells as they are
burned off during initial operation of the appliance. This is a
normal temporary occurrence. A window should be opened
during the initial bake out period.
• Keep burner and control compartment clean.
• WARNING: Before installing in a solid fuel burning re-
place, the chimney ue and rebox must be cleaned of soot,
creosote, ashes and loose paint by a qualied chimney clean-
er.
• Installation and repair should be done by a qualied service
person. The appliance should be inspected before use and at
least annually by a qualied service person. More frequent
cleaning may be required due to excessive lint from carpeting, bedding materials, etc. It is imperative that control compartments, burners and circulating air passageways of the ap-
pliance be kept clean.
• Do not put anything around the replace that will obstruct
the ow of ventilation air.
• Do keep the appliance area clear and free from combustible
material, gasoline and other ammable vapors and liquids.
• A yearly examination and cleaning of the venting system of
the solid-fuel burning replace must be performed by a qualied agency.
• Do make a periodic visual check of pilot and burners. Clean
and replace damaged parts.
• Do not use this appliance if any part has been under water.
Immediately call a qualied service technician to inspect the
appliance and to replace any part of the control system and
any gas control which has been under water.
• Never burn solid fuels in replace where a gas log set is installed.
• This unit complies with ANSI Z21.60 Decorative Vented
Appliances for Solid Fuel Burning Fireplaces. State or local
codes may only allow operation of this appliance in a vented
conguration. Check your state or local codes.
25736-0-0309Page 4