Whirlpool YWED85HEFW2, YMED5500FC2, YWED92HEFW2, YWED92HEFU2, YWED92HEFC2 Installation Guide

...
GAS DRYER INSTALLATION INSTRUCTIONS
CANADIAN ELECTRIC DRYER INSTRUCTIONS
INSTRUCTIONS POUR L’INSTALLATION
DE LA SÉCHEUSE À GAZ (É.-U. ET CANADA)
ÉLECTRIQUE (CANADA UNIQUEMENT)
Table of Contents
INSTALLATION REQUIREMENTS .............................................. 4
VENTING .................................................................................... 10
Venting Requirements ......................................................... 10
Plan Vent System ................................................................. 11
CONNECT VENT ....................................................................... 14
Para una version de estas instrucciones en español, visite www.Whirlpool.com
INSTALLATION NOTES
Date of purchase: _________________________________ Date of installation: ________________________________ Installer: ________________________________________ Model number: ___________________________________ Serial number: ____________________________________
Table des matières
SÉCURITÉ DE LA SÉCHEUSE ................................................. 26
EXIGENCES D’INSTALLATION ................................................ 28
Outillage et pièces ............................................................ 28
EXIGENCES D’EMPLACEMENT .............................................. 29
SÉCHEUSE ÉLECTRIQUE RACCORDEMENT À L’ALIMENTATION ÉLECTRIQUE – CANADA SEULEMENT ... 31
RACCORDEMENT D’UNE SÉCHEUSE À GAZ ....................... 31
INSTALLATION DES PIEDS DE NIVELLEMENT ..................... 33
RACCORDEMENT AU GAZ ...................................................... 34
ÉVACUATION ............................................................................ 34
Exigences concernant l’évacuation ................................ 34
Planication du système d’évacuation ........................... 35
Installation du système d’évacuation .............................. 37
RACCORDEMENT DU TUYAU D’ALIMENTATION
(MODÈLE À VAPEUR UNIQUEMENT) ..................................... 37
RACCORDEMENT DU CONDUIT D’ÉVACUATION ................ 39
RÉGLAGE DE L’APLOMB DE LA SÉCHEUSE......................... 39
ACHEVER L’INSTALLATION LISTE DE VÉRIFICATION .......... 40
INVERSION DE LA PORTE (FACULTATIF) ............................... 40
NOTES CONCERNANT L’INSTALLATION
Date d’achat: _____________________________________ Date d’installation: ________________________________ Installateur: ______________________________________ Numéro de modéle: ________________________________ Numéro de série: __________________________________
W11101368A
W11101371A-SP
DRYER SAFETY
2
WARNING:
FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury, death, or property
damage.
Do not store or use gasoline or other ammable vapors and liquids in the vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Clear the room, building, or area of all occupants.
Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s
instructions. If you cannot reach your gas supplier, call the re department.
Installation and service must be performed by a qualied installer, service agency, or the gas supplier.
IMPORTANT: The gas installation must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or the Natural Gas and Propane Installation Code, CSA B149.1.
The dryer must be electrically grounded in accordance with local codes, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, Part 1, CSA C22.1.
In the State of Massachusetts, the following installation instructions apply:
Installations and repairs must be performed by a qualified or licensed contractor, plumber, or gas fitter qualified or licensed by
the State of Massachusetts.
Acceptable Shut-off Devices: Gas Cocks and Ball Valves installed for use shall be listed.
A flexible gas connector, when used, must not exceed 4 feet (121.9 cm).
3
INSTALLATION REQUIREMENTS
Tools and Parts
Gather the required tools and parts before starting installation.
Tools needed for all installations:
Tools needed for gas installations:
Flat-blade screwdriver #2 Phillips screwdriver
1/4" (6 mm) and 5/16" (8 mm) nut driver (recommended)
Tape measure Pliers
Level
8" (203 mm) or 10" (254 mm) pipe wrench
Pipe-joint compound
resistant to propane gas
8" (203 mm) or 10" (254 mm) adjustable wrench (for gas connections)
Parts supplied (all models):
Leveling legs (4)
Parts needed (steam models):
Utility knife
Caulking gun and compound (new vent installations)
Tin snips (new vent installations)
Adjustable wrench that opens to 1" (25 mm) or hex-head socket wrench
“Y” connector
Rubber washer
Parts package is located in dryer drum. Check that all parts are included.
NOTE: Do not use leveling legs supplied with dryer if installing with a pedestal or a stack kit.
2' (0.6 m) inlet hose
5' (1.52 m) inlet hose
Parts needed (not supplied with dryer):
Vent clamps
Vent elbows and vent work
4
Additional parts may be required, depending on your installation. Check local codes. Check existing electrical supply and venting. Read “Electrical Requirements” and “Venting Requirements” before purchasing parts.
Optional Equipment (not supplied with dryer):
Refer to your Use and Care Guide for information about accessories available for your dryer.
LOCATION REQUIREMENTS
DRYER DIMENSIONS
Front view:
383/4" Min.
(984 mm)
39" Max.
(990 mm)
Side view:
27"
(686 mm)
You will need:
A location allowing for proper exhaust installation.
See “Venting Requirements.”
A separate 15- or 20-amp circuit for a gas dryer or 30-amp
circuit for an electric dryer.
If using power supply cord, a grounded electrical outlet
located within 2 ft. (610 mm) of either side of dryer. See “Electrical Requirements.”
Floor must support dryer weight of 200 lbs. (90.7 kg).
Also consider weight of companion appliance.
Cold water faucets located within 4 ft. (1.2 m) of the water
ll valves, and water pressure of 20–120 psi (138–827 kPa). You may use your washer’s water supply by purchasing the necessary parts noted in “Parts needed.”
Level oor with maximum slope of 1" (25 mm) under entire
dryer. If slope is greater than 1" (25 mm), install Extended Dryer Feet Kit, Part Number 279810. If not level, clothes may not tumble properly and automatic sensor cycles may not operate correctly.
For garage installation, place dryer at least 18" (460 mm)
above oor. If using a pedestal, you will need 18" (460 mm) to bottom of dryer.
The dryer must not be installed or stored in an area where
it will be exposed to water and/or weather.
IMPORTANT: Do not operate, install, or store dryer where it will be exposed to water, weather, or at temperatures below 40°F (4°C). Lower temperatures may cause dryer not to shut off at end of automatic sensor cycles, resulting in longer drying times.
Back view:
53/4"*
(146 mm)
Vent
Gas
Water inlet
(Steam Models Only)
*Approx. measurement
61/4"
(159 mm)
7
29
/8"*
(759 mm)
1
/2"*
3
(89 mm)
1
/8"*
6
3/4"*
(18 mm)
(365 mm)
253/4"
(654 mm)
14
3
/8"
(156 mm)
*Approx. measurement
NOTE: Most installations require a minimum of 5" (127 mm) clearance behind dryer for exhaust vent with elbow. See “Venting Requirements.”
5
Installation Clearances
For each arrangement, consider allowing more space for ease of installation and servicing, spacing for companion appliances, and clearances for walls, doors, and oor moldings. Space must be large enough to allow door to fully open. Add spacing on all sides of dryer to reduce noise transfer. If a closet door or louvered door is installed, top and bottom air openings in door are required.
Check code requirements. Some codes limit, or do not permit, installation of the dryer in garages, closets, mobile homes, or sleeping quarters. Contact your local building inspector.
NOTE: No other fuel-burning appliance can be installed in the same closet as a dryer.
Installation spacing for recessed area or closet installation
All dimensions show recommended and minimum spacing allowed.
Additional spacing should be considered for ease of
installation and servicing.
Additional clearances might be required for wall, door,
oor moldings, dryer venting, and gas line.
Additional spacing should be considered on all sides
of the dryer to reduce noise transfer.
For closet installation with a door, minimum ventilation
openings in the top and bottom of the door are required. Louvered doors with equivalent ventilation openings are acceptable.
Companion appliance spacing should also be considered.
Recommended installation clearances (dryer only):
Custom under-counter installation:
Mobile home – Additional installation requirements:
This dryer is suitable for mobile home installations. The installation must conform to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile home construction and Safety, Title 24, HUD Part 280) or Standard CAN/CSA-Z240 MH.
Mobile home installations require:
Metal exhaust system hardware, available for purchase
from your dealer. For further information, see “Assistance or Service” in your Use and Care Guide.
Special provisions must be made in mobile homes to
introduce outside air into dryer. Openings (such as a nearby window) should be at least twice as large as dryer exhaust opening.
For mobile home installation of gas dryers:
Mobile Home Installation Hold-down Kit Part Number 346764
is available to order. For further information, see “Assistance or Service” in your Use and Care Guide.
3"
(76 mm)
3"
(76 mm)
48 in.2 min.
(310 cm
24 in.2 min.
(155 cm2)
2
)
0–5"
(0–127 mm)
18" min.
(457 mm)
1"
(25 mm)
1"
(25 mm)
0" (0 mm) rear spacing is allowed for straight back venting only. For steam models only, inlet hose must not be kinked.
Minimum installation clearances (dryer only):
Front Sides Rear Top Recessed NA 0" (0 mm) 0" (0 mm)* 0" (0 mm) Closet NA 0" (0 mm) 0" (0 mm)* 0" (0 mm)
*0" (0 mm) spacing is allowed for straight back venting only.
6
ELECTRIC DRYER POWER HOOKUP – CANADA ONLY
ELECTRICAL REQUIREMENTS
It is your responsibility:
To contact a qualied electrical installer.
To be sure that the electrical connection is adequate and in
conformance with Canadian Electrical Code, C22.1 – latest edition and all local codes. A copy of above codes standard may be obtained from: Canadian Standards Association, 178 Rexdale Blvd., Toronto, ON M9W 1R3 CANADA.
To supply the required 4-wire, single phase, 120-/240-volt,
60 Hz, AC-only electrical supply on a separate 30-amp circuit, fused on both sides of the line. A time-delay fuse or circuit breaker is recommended. Connect to an individual branch circuit.
This dryer is equipped with a UL Listed
and/or CSA International Certied Power Cord intended to be plugged into a standard 14-30R wall receptacle. The cord is 5 ft. (1.52 m) long. Be sure wall receptacle is within reach of dryer’s nal location.
If using a replacement power supply cord, it is recommended that you use Power Supply Cord Replacement Part Number 8529008.
For further information, please reference service numbers located in the “Assistance or Service” section of your Use and Care Guide.
GROUNDING INSTRUCTIONS
For a grounded, cord-connected dryer:
This dryer must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current. This dryer is equipped with a cord having an equipment­grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.
4-wire receptacle
(14-30R)
GAS DRYER POWER HOOKUP
ELECTRICAL REQUIREMENTS
120-volt, 60 Hz, AC-only, 15- or 20-amp fused electrical
supply is required. A time-delay fuse or circuit breaker is recommended. It is also recommended that a separate circuit serving only this dryer be provided.
GROUNDING INSTRUCTIONS
For a grounded, cord-connected dryer:
This dryer must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current. This dryer is equipped with a cord having an equipment­grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.
WARNING: Improper connection of the equipment-
grounding conductor can result in a risk of electric shock. Check with a qualied electrician or service representative or personnel if you are in doubt as to whether the dryer is properly grounded. Do not modify the plug provided with the dryer: if it will not t the outlet, have a proper outlet installed by a qualied electrician.
SAVE THESE INSTRUCTIONS
WARNING: Improper connection of the equipment-
grounding conductor can result in a risk of electric shock. Check with a qualied electrician or service representative or personnel if you are in doubt as to whether the dryer is properly grounded. Do not modify the plug provided with the dryer: if it will not t the outlet, have a proper outlet installed by a qualied electrician.
SAVE THESE INSTRUCTIONS
7
GAS SUPPLY REQUIREMENTS
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to propane, have a qualified person make sure gas pressure does not exceed 13" (330 mm) water column.
Examples of a qualified person include: licensed heating personnel,
authorized gas company personnel, and authorized service personnel.
Failure to do so can result in death, explosion, or fire.
GAS TYPE
Natural Gas:
This dryer is equipped for use with natural gas. It is certied by UL for use with propane gas with appropriate conversion.
Your dryer must have the correct burner for the type of gas
in your home. Burner information is located on the rating plate in the door well of your dryer. If this information does not agree with the type of gas available, contact your dealer or call the phone numbers referenced in the “Assistance or Service” section of your Use and Care Guide.
Propane Gas Conversion:
IMPORTANT: Conversion must be made by a qualied
technician. No attempt shall be made to convert the appliance from the gas
specied on the model/serial rating plate for use with a different gas without consulting your gas company.
GAS SUPPLY LINE Option 1 (Recommended Method)
Flexible stainless steel gas connector:
If local codes permit, use a new exible stainless steel gas
connector (Design Certied by the American Gas Association or CSA International) to connect your dryer to the rigid gas supply line. Use an elbow and a 3/8" are x 3/8" NPT adapter tting between the stainless steel gas connector and the dryer gas pipe, as needed, to prevent kinking.
Option 2 (Alternate Method)
Approved aluminum or copper tubing:
Must include 1/8" NPT minimum plugged tapping accessible
for test gauge connection, immediately upstream of the gas connection to the dryer. See illustration.
1/2" IPS pipe is recommended.
3/8" approved aluminum or copper tubing is acceptable for
lengths under 20 ft. (6.1 m) if local codes and gas supplier permit.
If you are using natural gas, do not use copper tubing.
Lengths over 20 ft. (6.1 m) should use larger tubing and
a different size adapter tting.
If your dryer has been converted to use propane gas, 3/8"
propane compatible copper tubing can be used. If the total length of the supply line is more than 20 ft. (6.1 m), use larger pipe.
NOTE: Pipe-joint compounds that resist the action of propane gas must be used. Do not use TEFLON
Must include shut-off valve.
In the U.S.A.:
An individual manual shut-off valve must be installed within six (6) ft. (1.8 m) of the dryer in accordance with the National Fuel Gas Code, ANSI Z223.1. The location should be easy to reach for opening and closing.
In Canada:
An individual manual shut-off valve must be installed in accordance with the B149.1, Natural Gas and Propane Installation Code. It is recommended that an individual manual shut-off valve be installed within six (6) ft. (1.8 m) of the dryer. The location should be easy to reach for opening and closing.
E
C
A
B
A. 3/8" exible gas connector B. 3/8" pipe to are adapter tting C. 1/8" NPT minimum plugged tapping D. 1/2" NPT gas supply line E. Gas shut-off valve
®†
tape.
D
†®TEFLON is a registered trademark of Chemours.
8
*53/4" (146 mm)
1
1
/2"
(38 mm)
GAS SUPPLY CONNECTION REQUIREMENTS
Use an elbow and a 3/8"  are x 3/8" NPT adapter  tting
between the  exible gas connector and the dryer gas pipe, as needed to avoid kinking.
Use only pipe-joint compound. Do not use TEFLON
This dryer must be connected to the gas supply line with a
listed  exible gas connector that complies with the standard for connectors for gas appliances, ANSI Z21.24 or CSA 6.10.
®
tape.
BURNER INPUT REQUIREMENTS
Elevations above 2,000 ft. (610 m):
When installed above 2,000 ft. (610 m) a 4% reduction of the
burner Btu rating shown on the model/serial number plate is required for each 1,000 ft. (305 m) increase in elevation.
Gas supply pressure testing
The dryer must be disconnected from the gas supply
piping system during pressure testing at pressures greater than 1/2 psi.
DRYER GAS PIPE
The gas pipe that comes out through the rear of your dryer has
a 3/8" male pipe thread.
INSTALL LEVELING LEGS
1. Prepare dryer for leveling legs
3/8" NPT dryer gas pipe
* NOTE: If the dryer is mounted on a pedestal, the gas
pipe height must be an additional 10" (254 mm) or
15.5" (394 mm) from the  oor, depending on the pedestal model. For a garage installation, the gas pipe height must be an additional 18" (460 mm) from the  oor.
To avoid damaging  oor, use a large  at piece of cardboard from dryer carton; place under entire back edge of dryer. Firmly grasp dryer body (not console panel) and gently lay dryer down on cardboard.
2. Screw in leveling legs
Diamond
diamond
marking
marking
Examine leveling legs and locate the diamond marking. Screw legs into leg holes by hand – use a wrench to  nish turning legs until diamond marking is no longer visible.
Place a carton corner post from dryer packaging under each of the two dryer back corners. Stand the dryer up. Slide the dryer on the corner posts until it is close to its  nal location. Leave enough room to connect the exhaust vent.
9
A
B
A
B
C
D
MAKE GAS CONNECTION
(gas models only)
1. Connect gas supply to dryer
A. Flared male  tting B. Non- ared male  tting
Remove red cap from gas pipe. Using a wrench to tighten, connect gas supply to dryer. Use pipe-joint compound on threads of all non- ared male  ttings. If  exible metal tubing is used, be sure there are no kinks.
NOTE: For propane gas connections, you must use pipe­joint compound resistant to action of propane gas. Do not use TEFLON
®
tape.
2. Plan pipe  tting connection (option 1)
VENTING Venting Requirements
WARNING: To reduce the risk of  re, this dryer MUST BE
EXHAUSTED OUTDOORS. IMPORTANT: Observe all governing codes and ordinances.
Dryer exhaust must not be connected into any gas vent, chimney, wall, ceiling, attic, crawlspace, or a concealed space of a building. Only rigid or  exible metal vent shall be used for exhausting.
A. 3/8"  exible gas connector B. 3/8" dryer gas pipe
A combination of pipe  ttings must be used to connect dryer
to existing gas line. A recommended connection is shown. Your connection may be different, according to supply line type, size, and location.
C. 3/8" to 3/8" pipe elbow D. 3/8" pipe-to- are adapter
 tting
3. Open shut-off valve
A
B
A. Closed valve B. Open valve
Open shut-off valve in supply line; valve is open when handle
is parallel to gas pipe. Then, test all connections by brushing on an approved noncorrosive leak-detection solution. Bubbles will show a leak. Correct any leak found.
10
4"
(102 mm)
4" (102 mm) heavy metal exhaust vent
Only a 4" (102 mm) heavy metal exhaust vent and clamps
may be used.
Do not use plastic or metal foil vent.
Rigid metal vent:
Recommended for best drying performance and to avoid
crushing and kinking.
Flexible metal vent: (Acceptable only if accessible to clean)
Must be fully extended and supported in  nal dryer location.
Remove excess to avoid sagging and kinking that may
result in reduced air ow and poor performance.
Do not install in enclosed walls, ceilings, or  oors.
The total length should not exceed 7¾ ft. (2.4 m).
The length of  exible metal vent used must be included
in the overall vent system design as shown in the Vent System Charts.
NOTE: If using an existing vent system, clean lint from entire length of the system and make sure exhaust hood is not plugged with lint. Replace plastic or metal foil vents with rigid metal or  exible metal vents. Review Vent System Charts and, if necessary, modify existing vent system to achieve best drying performance.
Exhaust hoods:
An exhaust hood should cap the vent to keep rodents and
insects from entering the home.
Must be at least 12" (305 mm) from ground or any object
that may obstruct exhaust (such as owers, rocks, bushes, or snow).
Do not use an exhaust hood with a magnetic latch.
Plan Vent System
Recommended exhaust installation:
A
B C
D
Recommended Styles:
Louvered Hood
Box Hood
Acceptable Style:
Angled Hood
Elbows:
45° elbows provide better airow than 90° elbows.
Good Better
A. Dryer B Elbow C. Wall D. Exhaust hood E. Clamps
F
G
B
H
F. Rigid metal or exible
metal vent
G. Vent length necessary
to connect elbows
H. Exhaust outlet
E
Clamps:
Use clamps to seal all joints.
Exhaust vent must not be connected or secured with screws
or other fastening devices that extend into interior of duct and catch lint. Do not use duct tape.
Optional exhaust installations:
This dryer can be converted to exhaust out the right side, left side (all models except long vent), or through the bottom. If you prefer, you may contact your local dealer to have the dryer converted.
A B C
A. Standard rear offset exhaust installation B. Left- or right-side exhaust installation C. Bottom exhaust installation
11
Special provisions for mobile homes:
Exhaust vent must be securely fastened to a noncombustible portion of mobile home and must not terminate beneath the mobile home. Terminate exhaust vent outside.
Long Vent System Chart
Number of
90° elbows
0 1 2 3 4
To determine if your model has a long vent system, refer to the type code located on the serial number plate in the inner door well. Example: An electric model would be DALV – ELE – XXXXXXX-XXX. A gas model would be DALV – GAS – XXXXXXX-XXX.
NOTE: For long vent systems, use of box/louvered hoods will improve venting regardless of length.
Type
of vent Rigid metal 160 ft. (48.8 m) Rigid metal 150 ft. (45.7 m) Rigid metal 140 ft. (42.7 m) Rigid metal 130 ft. (39.6 m) Rigid metal 120 ft. (36.6 m)
Angled
hoods
Install Vent System
1. Install exhaust hood
Determine vent path:
Select route that will provide straightest and most direct
path outdoors.
Plan installation to use fewest number of elbows and turns.
When using elbows or making turns, allow as much room
as possible.
Bend vent gradually to avoid kinking.
Use as few 90° turns as possible.
Determine vent length and elbows needed for best drying performance:
Use the following “Vent System Charts” to determine type
of vent material and hood combinations acceptable to use. NOTE: Do not use vent runs longer than those speci ed
in “Vent System Charts.” Exhaust systems longer than those speci ed will:
Shorten life of dryer.
Reduce performance, resulting in longer drying times
and increased energy usage.
The “Vent System Charts” provide venting requirements that will help achieve best drying performance.
Standard Vent System Chart
Number of 90° elbows
0 1 2 3 4
Type
of vent Rigid metal 64 ft. (20 m) Rigid metal 54 ft. (16.5 m) Rigid metal 44 ft. (13.4 m) Rigid metal 35 ft. (10.7 m) Rigid metal 27 ft. (8.2 m)
Angled
hoods
12" min.
(305 mm)
12" min.
(305 mm)
Install exhaust hood and use caulking compound to seal exterior wall opening around exhaust hood.
2. Connect vent to exhaust hood
Vent must  t over the exhaust hood. Secure vent to exhaust hood with 4" (102 mm) clamp. Run vent to dryer location using straightest path possible. Avoid 90° turns. Use clamps to seal all joints. Do not use duct tape, screws, or other fastening devices that extend into interior of vent to secure vent, because they can catch lint.
12
CONNECT INLET HOSE (STEAM MODEL ONLY)
For non-steam models, skip to “Connect Vent.” The dryer must be connected to the cold water faucet using
the new inlet hoses (not supplied). Do not use old hoses. NOTE: Replace inlet hoses after 5 years of use to reduce the
risk of hose failure. Record hose installation or replacement dates on the hoses for future reference.
Periodically inspect and replace hoses if bulges, kinks, cuts, wear, or leaks are found.
1. Turn cold water off, remove hose,
and replace rubber washer
3. Tighten couplings
Using pliers, tighten the couplings with additional 2/3 turn.
NOTE: Do not overtighten. Damage to the coupling can result.
4. Attach long hose to “Y”
connector and tighten couplings
Turn cold water faucet off and remove washer inlet hose. Remove old rubber washer from inlet hose and replace with
new rubber washer.
2. Attach short hose and “Y” connector
Attach 2 ft. (0.6 m) inlet hose to cold water faucet. Screw on coupling by hand until it is seated on faucet. Then attach “Y” connector to male end of the 2 ft. (0.6 m) inlet hose. Screw on coupling by hand until it is seated on connector.
Attach one of the 5 ft. (1.5 m) inlet hose ends to the “Y” connector. Attach washer cold inlet hose to other side of “Y” connector. Screw on coupling by hand until it is seated on connector. Using pliers, tighten the couplings an additional 2/3 turn.
NOTE: Do not overtighten. Damage to the coupling can result.
13
5. Attach long hose to dryer  ll valve
and tighten coupling
Remove protective cap from water inlet valve. Attach other end of long hose to  ll valve at bottom of dryer back panel. Screw on coupling by hand until it is seated on  ll valve connector. Using pliers, tighten the couplings an additional 2/3 turn.
NOTE: Do not overtighten. Damage to the coupling can result.
CONNECT VENT
1. Connect vent to exhaust outlet
Using a 4" (102 mm) clamp, connect vent to exhaust outlet in dryer. If connecting to existing vent, make sure vent is clean. Dryer vent must  t over dryer exhaust outlet and inside exhaust hood. Check that vent is secured to exhaust hood with a 4" (102 mm) clamp.
2. Move dryer to  nal location
6. Turn on cold water faucet
Check that the water faucets are turned on.
7. Check for leaks
Move dryer to  nal location, taking care not to crush or
kink vent or  exible gas line.
After dryer is in place, remove corner posts and cardboard
from under dryer.
Check for leaks around “Y” connector, faucet, and hoses.
14
LEVEL DRYER
1. Level dryer
Place
level here
Check levelness of dryer from side to side. Repeat from front to back.
NOTE: The dryer must be level for the moisture sensing system to operate correctly.
Not Level LEVEL Not Level
COMPLETE INSTALLATION CHECKLIST
Check that all parts are now installed. If there is an extra
part, go back through steps to see what was skipped.
Check that you have all of your tools.
Dispose of/recycle all packaging materials.
Be sure the water faucets are on.
Check for leaks around “Y” connector, faucet, and hoses.
Check dryer’s  nal location. Be sure vent is not crushed
or kinked.
Check that dryer is level. See “Level Dryer.”
Remove  lm on console and any tape remaining on dryer.
Wipe dryer drum interior thoroughly with a damp cloth to
remove any dust.
Read “Dryer Use” in your Use and Care Guide.
If you live in a hard water area, use of a water softener is
recommended to control the buildup of scale through the water system in the dryer. Over time, the buildup of lime scale may clog different parts of the water system, which will reduce product performance. Excessive scale buildup may lead to the need for certain part replacement or repair.
Electric Models:
Plug into a grounded outlet.
Gas Models:
Plug into a grounded outlet.
Check that gas supply is on.
Check for leaks.
Check to be sure that the  exible gas line is not crushed
or kinked.
2. Adjust leveling legs
If dryer is not level, prop up using a wood block, use wrench to adjust legs up or down, and check again for levelness. Once dryer is level, make sure all four legs are snug against the  oor and the dryer does not rock.
All Models:
Select a Timed Dry heated cycle and start dryer. Do not
select Air Only Temperature setting.
If dryer will not start, check the following:
• Start button has been pressed  rmly.
• Dryer is plugged into an outlet and/or electrical supply is connected.
• Household fuse is intact and tight, or circuit breaker has not tripped.
• Dryer door is closed.
This dryer automatically runs an installation diagnostic routine at the start of its  rst cycle.
NOTE: You may notice an odor when dryer is  rst heated. This odor is common when heating element is  rst used. The odor will go away.