Whirlpool YMEDZ600TW, YMEDZ600TK, YMEDZ600TE, YMEDZ600TB, YMEDZ400TQ Installation Instructions

...
DRYER INSTALLATION INSTRUCTIONS
GAS (U.S.A. AND CANADA)
ELECTRIC (CANADA ONLY)
INSTRUCTIONS D’INSTALLATION DE LA SÉCHEUSE
À GAZ (É.-U. ET CANADA)
ÉLECTRIQUE (CANADA UNIQUEMENT)

Para una version de estas intrucciones en español, visite www.Whirlpool.com

TABLE OF CONTENTS

DRYER SAFETY..............................................................................2
Tools and Parts ............................................................................4
Optional Equipment .....................................................................4
Location Requirements................................................................4
ELECTRIC DRYER POWER HOOKUP – CANADA ONLY
Electrical Requirements ...............................................................7
GAS DRYER POWER HOOKUP.................................................... 8
Gas Supply Requirements ...........................................................8
Make Gas Connection .................................................................9
VENTING .........................................................................................9
Venting Requirements..................................................................9
Plan Vent System.......................................................................10
Install Vent System.....................................................................12
INSTALL LEVELING LEGS...........................................................12
CONNECT VENT...........................................................................12
LEVEL DRYER ..............................................................................12
COMPLETE INSTALLATION .......................................................12
REVERSE DOOR SWING.............................................................13
TROUBLESHOOTING ..................................................................14
Dryer Operation..........................................................................14
Dryer Results..............................................................................15
..........7

TABLE DES MATIÈRES

SÉCURITÉ DE LA SÉCHEUSE ....................................................16
EXIGENCES D’INSTALLATION...................................................18
Outillage et pièces......................................................................18
Équipement facultatif .................................................................18
Exigences d'emplacement.........................................................18
RACCORDEMENT DE L’ALIMENTAT
SÉCHEUSE ÉLECTRIQUE...........................................................21
Spécifications électriques ..........................................................21
RACCORDEMENT DE L’ALIMENTATION
À LA SÉCHEUSE À GAZ ..............................................................22
Alimentation en gaz....................................................................22
Raccordement au gaz................................................................23
ÉVACUATION................................................................................23
Exigences concernant l’évacuation ...........................................23
Planification du système d’évacuation ......................................25
Installation du système d’évacuation
INSTALLATION DES PIEDS DE NIV
RACCORDEMENT DU CONDUIT D’ÉVACUATION ..................26
RÉGLAGE DE L’APLOMB DE LA INVERSION DU SENS D’OUVERTURE DE
ACHEVER L’INSTALLATION .......................................................27
DÉPANNAGE.................................................................................29
Fonctionnement de la sécheuse................................................29
Résultats de la sécheuse ...........................................................29
ION À LA
.........................................26
ELLEMENT........................26
SÉCHEUSE...........................27
LA PORTE .............27
W10261613A W10267630A - SP

DRYER SAFETY

Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages.
This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others. All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.”
These words mean:
You can be killed or seriously injured if you don't immediately
DANGER
WARNING
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.
follow instructions.
can be killed or seriously injured if you don't
You instructions.
follow
2
WARNING: For your safety, the information in this manual must be followed to minimize the risk of re or explosion, or to prevent property damage, personal injury, or death.
– Do not store or use gasoline or other ammable vapors and liquids in the vicinity of this
or any other appliance.
– WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Clear the room, building, or area of all occupants.
Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's
instructions. If you cannot reach your gas supplier, call the re department.
– Installation and service must be performed by a qualied installer, service agency, or
the gas supplier.
WARNING: Gas leaks cannot always be detected by smell.
Gas suppliers recommend that you use a gas detector approved by UL or CSA. For more information, contact your gas supplier. If a gas leak is detected, follow the “What to do if you smell gas” instructions.
IMPORTANT: The gas installation must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54 or the Canadian Natural Gas and Propane Installation Code, CSA B149.1.
The dryer must be electrically grounded in accordance with local codes, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70 or Canadian Electrical Code, CSA C22.1.
In the State of Massachusetts, the following installation instructions apply:
Installations and repairs must be performed by a qualied or licensed contractor, plumber, or gastter qualied or licensed by
the State of Massachusetts.
If using a ball valve, it shall be a T-handle type.
A exible gas connector, when used, must not exceed 3 feet.
3

INSTALLATION REQUIREMENTS

Tools and Parts

Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here.
For All Installations:
Flat-blade screwdriver
#2 Phillips screwdriver
Adjustable wrench that
opens to 1" (25 mm) or hex-head socket wrench (for adjusting dryer feet)
Level
Vent clamps
Caulking gun and
compound (for installing new exha
ust vent)
Tin snips (new vent
installations)
¼" nut driver
(recommended)
Tap e me asu re
Pliers
Gas Installations:
8" or 10" pipe wrench
8" or 10" adjustable wrench
Pipe-joint compound
resistant to LP gas
(for gas connections)

Parts supplied

4 Leveling legs
Remove parts package from dryer drum. Check that all parts are included.
NOTE: Do not use leveling legs supplied with dryer if installing on a pedestal.

Parts needed

Check local codes. Check existing electrical supply and venting. See “Electrical Requirements” and “Venting Requirements” before purchasing parts.
Mobile home installations require available for purchase from the dealer from whom you purchased your dryer. For further information, please refer to the “Assistance or Service” section in your Use and Care Guide.
metal exhaust system hardware

Optional Equipment

Refer to your Use and Care guide for information about the accessories available for your dryer.

Location Requirements

You will need

A location that allows for proper exhaust installation.
See “Venting Requirements.”
A separate 30-amp circuit.
If you are using a power supply cord, a grounded electrical
outlet located within 2 ft. (610 mm) of either side of the dryer. See “Electrical Requirements.”
A sturdy floor to support the total dryer weight of 127 lbs
(57.6 kg). The combined weight of a companion appliance should also be consider
A level floor with a maximum slope of 1" (25 mm) under entire
dryer. If slope is greater than 1" (25 mm), install Extended Dryer Feet Kit, Part Number 279810. Clothes may not tumble properly and automatic sensor cycles may not operate correctly if dryer is not level.
For a garage installation, you will need to place the dryer at least
18" (460 mm) above the floor. If using a pedestal, you will need 18" (460 mm) to the bottom of the dryer.
Do not operate your dryer at temperatures below 45ºF (7ºC). At lower temperatur
es, the dryer might not shut off at the end of an
automatic sensor cycle. This can result in longer drying times. The dryer must not be installed or stored in an area where it will be
exposed to
water and/or weather.
Check code requirements. Some codes limit, or do not permit,
stallation of the dryer in garages, closets, mobile homes, or
in sleeping quarters. Contact your local building inspector.

Installation clearances

The location must be large enough to allow the dryer door to open fully.
ed.
4
Dryer Dimensions
Recessed or closet installation - Dryer on pedesta
l
501⁄2 "
(1283 mm)
36"
(914 mm)
*29"
(728 mm)
27"
(686 mm)
NOTE: Most installations require a minimum 5" (127 mm) clearance behind the dryer for the exhaust vent with elbow. See “Venting Requirements.”

Installation spacing for recessed area or closet installation

The following spacing dimensions are recommended for this dryer. This dryer has been tested for spacing of 0" (0 mm) clearance on the sides an following reasons:
Additional spacing should be considered for ease of installation
Additional clearances might be required for wall, door, and floor
Additional spacing should be considered on all sides of the dryer
For closet installation, with a door, minimum ventilation openings
Companion appliance spacing should also be considered.
Custom undercounter installation - Dryer only
d rear. Recommended spacing should be considered for the
and servicing.
moldings.
to reduce noise transfer.
in the top and bottom of the door are required. Louvered doors with equivalent ventilation openings are acceptable.
2"* (50 mm)
36" min
(914 mm)
14" max.* (356 mm)
15" min.*
(381 mm)
1"
(25 mm)
27"
(686 mm)
1"
(25 mm)
1"*
(25 mm)
29"
(728 mm)
5
"**
(127 mm)
* Required spacing **For side or bottom venting, 0" (0 mm) spacing is allowed
Recommended installation spacing
For cabinet installation, with a door, minimum ventilation
for cabinet installation
openings in the top of the cabinet are required.
7"* (178 mm)
7"* (178 mm)
5"**
(127 mm)
29"
(728 mm)
1"* (25 mm)
1"
(25 mm)
27"
(686 mm)
1" (25 mm)
* Required spacing **For side or bottom venting, 0" (0 mm) spacing is allowed.
9"* (229 mm)
1"*
(25 mm)
27"
(686 mm)
1"*
(25 mm)
*Required spacing
Closet installation - Dryer only
3"*
(76 mm)
(76 mm)
1"*
(25 mm)

Side view

14" max.* (356 mm)
15" min.* (381 mm)
5"**
29"
(127 mm)
(727 mm)
2*
48 in.
(310 cm2)
2
24 in.
(155 cm2)
*

Closet door with vents

* Required spacing **For side or bottom venting, 0" (0 mm) spacing is allowed.
3"*
5
Recommended installation spacing for recessed or closet installation, with stacked washer and dryer
The dimensions shown are for th
48 in.2 *
(310 cm2)
2
24 in.
*
(155 cm2)
e recommended spacing.
3"* (76 mm)
3"* (76 mm)
1"* (25 mm)
6"* (152 mm)
72"
(1829 mm)

Mobile home - Additional installation requirements

This dryer is suitable for mobile home installations. The installation must conform to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD Part 280) or Standard CAN/CSA-Z240 MH.

Mobile home installations require:

All Dryers
Metal exhaust system hardware, which is available for purchase
from your dealer.
Special provisions must be made in mobile homes to introduce
outside air into the dryer. The opening (such as a nearby window) should be at least twice as large as the dryer exhaust opening.
For gas dryers
Mobile Home Installation Kit Part Number 346764. See “Tools
and Parts” section for information on ordering.
5½"** (140 mm)
*Required spacing
1"
(25 mm)
27"
(686 mm)
1"
(25 mm)
6

ELECTRIC DRYER POWER HOOKUP – CANADA ONLY

This dryer is equipped with a CSA International Certified Power

Electrical Requirements

WARNING
Cord intended to be plugged into a standard 14-30R wall receptacle. The cord is 5 ft (1.52 m) in length. Be sure wall receptacle is within reach of dryer’s final location.

4-wire receptacle 14-30R

Electrical Shock Hazard Plug into a grounded 4 prong outlet. Failure to do so can result in death or electrical shock.

It is your responsibility

To contact a qualified electrical installer.
To be sure that the electrical connection is adequate and in
conformance with the Canadian Electrical Code, C22.1-latest edition and all local codes. A copy of the above codes standard may be obtained from: Canadian Standards Association, 178 Rexdale Blvd., Toronto, ON M9W 1R3 CANADA.
To supply the required 4 wire, single phase, 120/240 volt,
60 Hz., AC only electrical supply on a separate 30-amp circuit, f
used on both sides of the line. A time-delay fuse or circuit breaker is recommended. Connect to an individual branch circuit.
If using a replacement power supply cord, it is recommended that you use Power Supply Cord Replacement Part Number 9831317. For further information, please reference the service numbers located in the “Assistance or Service” section of your Use and Care Guide.
GROUNDING INSTRUCTIONS
For a grounded, cord-connected dryer:
This dryer must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current. This dryer is equipped with a cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.
WARNING: Improper connection of the
equipment-grounding conductor can result in a risk of electric shock. Check with a qualied electrician or service representative or personnel if you are in doubt as to whether the dryer is properly grounded. Do not modify the plug provided with the dryer: if it will not t the outlet, have a proper outlet installed by a qualied electrician.
SAVE THESE INSTRUCTIONS
7

GAS DRYER POWER HOOKUP

Gas Supply Requirements

WARNING
Explosion Hazard Use a new CSA International approved gas supply line. Install a shut-off valve. Securely tighten all gas connections. If connected to LP, have a qualied person make sure
gas pressure does not exceed 13" (330 mm) water column.
Examples of a qualied person include: licensed heating personnel,
authorized gas company personnel, and authorized service personnel.
Failure to do so can result in death, explosion, or re.
Gas Type
Natural gas:
This dryer is equipped for use with Natu certified by CSA International for LP (pr with appropriate conversion.
Your dryer must have the correct burner for the type of gas in
your home. Burner information is located on the rating plate in the door well of your dryer. If this information does not agree with the type of gas available, contact your dealer or call the phone numbers referenced in the “Assistance or Service” section.
LP gas conversion: Conversion must be m
ade by a qualified technician.
No attempt shall be made to con specified on the model/serial rating plate for use with a different gas without consulting your gas company.
Gas supply line
Must include 1/8" NPT minimum plugged tapping accessible
for test gauge connection, immediately upstream of the gas con
nection to the dryer.
1/2" IPS pipe is recommended.
3/8" approved aluminum or copper tubing is acceptable for
lengths under 20 ft. (6.1 m) if local codes and gas supplier permit.
If you are using Natural gas, do not use copper tubing.
ral gas. It is design-
opane or butane) gases
vert the appliance from the gas
Lengths over 20 ft. (6.1 m) should use larger tubing and a
different size adapter fitting.
If your dryer has been converted to use LP gas, 3/8" LP
compatible copper tubing can be used. If the total length of the supply line is more than 20 ft. (6.1 m), use larger pipe.
NOTE: P must be used. Do not use TEFLON
Must include a shutoff valve:
ipe-joint compounds that resist the action of LP gas
®†
tape.
In the U.S.A.:
An individual manual shutoff valve must be
installed within six (6) feet (1.8 m) of the dryer in accordance with the National Fuel Gas Code, ANSI Z223.1. The location should be easy to reach for opening and closing.
In Canada:
An individual manual shutof
f valve must be installed in accordance with the B149.1, Natural Gas and propane Installation Code. It is recommended that an individual manual shutoff valve be installed within six (6) ft. (1.8 m) of the dryer. The location should be easy to reach for opening and closing.
A
B
A. 3/8" flexible gas connector B. 3/8" pipe to flare adapter
fitting
C
E
D
C. 1/8" NPT minimum
plugged tapping
D. 1/2" NPT gas supply line
E. Gas shutoff valve
Gas supply connection requirements
Use an elbow and a 3/8" flare x 3/8" NPT adapter fitting
between the flexible gas connector and the dryer gas pipe, as needed to avoid kinking.
Use only pipe-joint compound. Do not use TEFLON
This dryer must be connected to the gas supply line with a
®†
tape.
listed flexible gas connector that complies with the standard for connectors for gas appliances, ANSI Z21.24 or CSA 6.10.
Burner input requirements

Elevations above 10,000 ft (3,048 m):

When installed above 10,000 ft (3,048 m) a 4% reduction of the
burner Btu rating shown on the model/serial number plate is required for each 1,000 ft (305 m) increase in elevation.

Gas supply pressure testing

The dryer must be disconnected from the gas supply piping
system during pressure testing at pressures greater than ½ psi.
®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.
8
Dryer gas pipe
A
3. Open the shutoff valve in the supply line. The valve is open when
the handle is parallel to the gas pipe.
The gas pipe that comes out through the rear of your dryer has a
3/8" male pipe thread.
*6¼" (159 mm)
A
A. 1/2" NPT gas supply line B. 3/8" NPT dryer pipe
1½" (38 mm)
B
*NOTE: If the dryer is mounted on a pedestal, the gas pipe
height must be an additional 10" (254 mm) or 15.5" (394 mm)
om the floor, depending on the pedestal model. For a garage
fr installation, the gas pipe height must be an additional 18" (460 mm) from the floor.

Make Gas Connection

1. Remove the red cap from the gas pipe.
2. Usin
g a wrench to tighten, connect the gas supply to the dryer. Use pipe-joint compound on the threads of all non-flared male fittings. If flexible metal tubing is used, be sure there are no kinks.
B
A
B
A. Closed valve B. Open valve
4. Test all connections by brushing on an approved noncorrosive
leak-detection solution. Bubbles will show a leak. Correct any leak found.

VENTING

Venting Requirements

WARNING
Fire Hazard Use a heavy metal vent. Do not use a plastic vent. Do not use a metal foil vent. Failure to follow these instructions can result in death
or re.
A. Flared male fitting B. Non-flared male fitting
NOTE: For LP gas connections, you must use pipe-joint compound resistant to the action of LP gas. Do not use TEFLON
®†
tape.
A combination of pipe fittings must be used to connect the dryer
e existing gas line. Shown is a recommended connection.
to th Your connection may be different, according to the supply line type, size and location.
D
A
B
A. 3/8" flexible gas
connector
B. 3/8" dryer pipe
C. 3/8" to 3/8" pipe elbow D. 3/8" pipe-to-flare
ad
apter fitting
C
WARNING: To reduce the risk of fire, this dryer MUST BE
EXHAUSTED OUTDOORS. IMPORTANT: Obse The dryer exhaust must not be connected into any gas vent,
imney, wall, ceiling, attic, crawlspace, or a concealed space
ch of a building. Only rigid or flexible metal vent shall be used for
usting.
exha
If using an existing vent system
Clean lint from the entire length of the system and make sure
exhaust hood is not plugged with lint.
Replace any plastic or metal foil vent with rigid or flexible heavy
metal vent.
Review vent system chart. Modify existing vent system if
necessary to achieve the best drying performance.
rve all governing codes and ordinances.
®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.
9
If this is a new vent system
H
G
E
D
C
Vent material
Use a heavy metal vent. Do not use plastic or metal foil vent.
4" (102 mm) heavy metal exhaust vent and clamps must be
used.
4"
102 mm
4" (102 mm) heavy metal exhaust vent
Vent products can be purchased from your dealer or by calling Whirlpool Service. For more information, see the “Assistance or Service” section.
Rigid metal vent
For best drying performance, rigid metal vents are
recommended.
Rigid metal vent is recommended to avoid crushing and kinking.
Flexible met
Flexible metal vents are acceptable only if accessible for
cleaning.
Flexible metal vent must be fully extended and supported when
the dryer is in its final location.
Remove excess flexible metal vent to avoid sagging and kinking
that may result in reduced airflow and poor performance.
Do not install flexible metal vent in enclosed walls, ceilings, or
floors.
The total length of flexible metal vent should not exceed
7¾ ft. (2.4 m).
Elbows
45° elbows provide better airflow than 90° elbows.
al vent
Exhaust
B
4"
A
4" (102 mm)
4" (102 mm)
Recommended:
A. Louvered hood style
B. Boxed hood style
An exhaust hood should cap the vent to keep rodents and
(102 mm)
Acceptable:
C. Angled hood
C
2½"
(64 mm)
style
insects from entering the home.
Exhaust hood must be at least 12" (305 mm) from the ground
or any object that may be in the path of the exhaust (such as
s, rocks or bushes, snow line, etc.).
flower
Do not use an exhaust hood with a magnetic latch.
Improper venting can cause moisture and lint to collect indoors, which may result in:
Moisture damage to woodwork, furniture, paint, wallpaper, carpets, etc.
Housecleaning problems and health problems.

Plan Vent System

Choose your exhaust installation type
Recommended exhaust installations
Typical installations vent the dryer from the rear of the dryer. Other installations are possible.
B
Good Better
Clamps
Use clamps to seal all joints.
Exhaust vent must not be connected or secured with screws or
other fastening devices that extend into the interior of the duct and catch lint. Do not use duct tape.
Clamp
10
A
A. Dryer B. Elbow
C. Wall
D. Exhaust hood
F
E. Clamps
F. Rigid metal or flexible metal vent G. Vent length necessar H. Exhaust outlet
y to connect elbows
Loading...
+ 22 hidden pages