INSTALLATIONINSTRUCTIONS
30"(76.2CM)FREESTANDINGANDSLIDE-INELECTRICRANGES
INSTRUCTIONSPOURL'INSTALLATION
DELACUISINIEREELECTRIQUEAUTOPORTANTEOU
ENCASTRABLEDE30"(76,2CM)
Table of Contents/Table des matieres ............................................................................. 2
IMPORTANT: Save installation instructions for local electrical inspector's use.
IMPORTANT : Conserver les instructions d'installation a I'usage de I'inspecteur local des installations electriques
TABLEOFCONTENTS
TABLEDESMATIERES
RANGE SAFETY ............................................................................. 2
INSTALLATION REQUIREMENTS ................................................ 3
Toels and Parts ............................................................................ 3
Lecation Requirements ................................................................ 3
Electrical Requirements - U.S.A. Only ......................................... 5
Electrical Requirements - Canada Only ....................................... 5
Countertop Preparation (for Slide-in Ranges Only) ..................... 6
INSTALLATION INSTRUCTIONS .................................................. 6
Unpack Range .............................................................................. 6
Install Anti-Tip Bracket ................................................................. 6
Optional Rear Spacer Cover (for Slide-in Ranges Only) .............. 7
Electrical Connection - U.S.A. Only ............................................. 8
Verify Anti-Tip Bracket Location ................................................ 11
Level Range ................................................................................ 12
Complete Installation ................................................................. 12
Moving the Range ...................................................................... 12
S¢CURITI :!:DE LA CUISINICRE ................................................... 13
EXIGENCES D'INSTALLATION ................................................... 13
Outillage et pieces ...................................................................... 13
Exigences de I'emplacement d'installation ............................... 14
Specifications de I'installation electrique -
Canada seulement ..................................................................... 15
Preparation du plan de travail (pour cuisinieres
encastrables uniquement) .......................................................... 16
INSTRUCTIONS D'INSTALLATION ............................................. 16
Deballage de la cuisiniere .......................................................... 16
Installation de la bride antibasculement .................................... 16
Obturation de I'espace h I'arriere (pour cuisinieres
encastrables uniquement) .......................................................... 17
Verification de I'emplacement de la bride
anti-basculement ........................................................................ 18
Mise a niveau de la cuisiniere .................................................... 18
Achever I'installation .................................................................. 18
Deplacement de la cuisiniere ..................................................... 19
RANGESAFETY
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word "DANGER" or "WARNING."
These words mean:
You can be killed or seriously injured if you don't immediately
follow instructions.
You can be killed or seriously injured if you don't follow instructions.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.
Tip Over Hazard
A child or adult can tip the range and be killed. Connect anti=tip bracket to rear range foot.
Reconnect the antFtip bracket, if the range is moved. Failure to follow these instructions can result in death or serious burns to children and adults.
INSTALLATIONREQUIREMENTS
Assemble the required tools and parts before starting installation.
Read and follow the safety instructions provided with any tools listed here.
Tools needed
Tape measure 3/8"drive rachet
Flat-blade screwdriver 1_,,nut driver
Level 8/18"nut driver
Hammer 1/8"(3.2 mm) drill bit (for
Hand or electric drill wood floors)
Channel lock pliers 8/18"(4.8 mm) carbide-tipped masonry drill bit (for
Marker or pencil concrete/ceramic floors)
Masking tape
Parts supplied
Check that all parts are included.
B
.......................0
A. Anti-tip bracket
B. Plastic anchors (2) C. #10x _" screws (2) D. Rear spacer cover for slide-in models
(supplied on some models)*
*To order, contact your dealer or refer to the "Assistance or Service"
section of your Use and Care Guide. Ask for Part No. 9757784WH
(White), 9757784BT (Biscuit), 9757784BL (Black), 9757784MT (Meteorite) or 9757784SS (Stainless Steel).
IMPORTANT: Observe all governing codes and ordinances. Failure to meet codes and ordinances could lead to fire or
electrical shock.
It is the installer's responsibility to comply with installation clearances specified on the model/serial rating plate. The model/serial rating plate is located on the oven frame behind the storage drawer panel.
The range should be located for convenient use in the kitchen.
To eliminate the risk of burns or fire by reaching over heated surface units, cabinet storage space located above the surface units should be avoided. If cabinet storage is to be provided, the risk can be reduced by installing a range hood that projects horizontally a minimum of 5" (12.7 cm) beyond
the bottom of the cabinets.
Cabinet opening dimensions that are shown must be used. Given dimensions are minimum clearances.
The floor anti-tip bracket must be installed. To install the anti-tip bracket shipped with the range, see "Install Anti-Tip
Bracket" section.
Grounded electrical supply is required. See "Electrical Requirements" section.
Mobile Home - Additional Installation Requirements The installation of this range must conform to the Manufactured
Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile Home Construction
and Safety, Title 24, HUD Part 280). When such standard is not applicable, use the Standard for Manufactured Home
Installations, ANSI A225.1/NFPA 501A or with local codes. In Canada, the installation of this range must conform with the
current standards CAN/CSA-A240-1atest edition, or local codes.
Mobile home installations require:
When this range is installed in a mobile home, it must be secured to the floor during transit. Any method of securing
the range is adequate as long as it conforms to the standards listed above.
Four-wire power supply cord or cable must be used in a mobile home installation. The appliance wiring will need to be
revised. See "Electrical Connection" section.
Brackets must be securely mounted to subfloor. Thickness of flooring may require longer screws to anchor bracket to
subfloor. Longer screws are available from your local hardware store.
Parts needed
Check local codes. Check existing electrical supply. See "Electrical Requirements" section.
All electrical connections should be made by a licensed, qualified
electrical installer.
Product Dimensions
Installation Clearances
Freestanding Range
(7&2 era)
Slide-in Range
30" /3_
30"
(76.2 sin)
} J_ 43%
(111.4 cm)
overall
height
I
36" (61.4 cm) coektep height
with _eveling legs _ewered
11/=turns
Cabinet opening dimensions shown are for 25" (64 cm) countertop depth, 24" (61 cm) base cabinet depth and
36" (91.4 cm) countertop height.
Freestanding Range
13" (33 cm) max. upper cabinet depth
30" (76.2 cm) rain. opening width
18" (45.7 era) upper cabinet
30" (7&2 cm) miu.
I
4" (10.2 ore) Juuction box = miu. c_earauce 8" (20.3 cm) to
from both sides 22" (55.9 era) from of range to side
wall or other T' (17.6 cm} max. combnstiMe from door,
material II .--/t /
_ 1 _" "_" n Yd' (2.2 cm}
\ \ _ between cutout
"" \_1 and cabinet
width
_ired
door er hinge=
For minimum
/ _earance to
the top ef the cooktop, see
NOTE.
35 %" (90.5 urn) cooktop height
with leveling
legs lowered 1V_turns
30"
*27"
to handle
(76.2 cm)
*When installed in a 24" (61 cm) base cabinet with 25" (63.5 cm)
countertop; front of oven door protrudes 1%" (4.8 cm) beyond 24" (61 cm) base cabinet.
Slide-in Range
imum
ee to
I upper cabinet depth_,-_ I/ the !op of the
30"(76.2 em) _L c.oo_ktop,see
_t I_ --oP_.in;-Jid_h ., NOTE.
18" (45.7 cm) [57.8 cm) upper cabinet to opening depth
.30" (76.2 era)
4" (10.2 cm) rain. clearance from both sides of
range to side wall or other combustible
material between upper cabinet and conntertop.
m
m
NOTE: 24" (61 cm) minimum when bottom of wood or metal cabinet is protected by not less than W' (0.64 cm) flame retardant
millboard covered with not less than No. 28 MSG sheet steel,
0.015" (0.4 ram) stainless steel, 0.024" (0.6 mm) aluminum or
0.020" (0.5 ram) copper. 30" (76.2 cm) minimum clearance between the top of the cooking
platform and the bottom of an unprotected wood or metal cabinet.
opening width
Junction box -
22" (55.9 cm) from
8" (20.3 cm) to either cabinet,
7" (17.8 cm) max.
/ from floor.
%" (2.2 cm)m'_in'_"'-._ required between
cutout and cabinet door or hinge.
Ifcodespermitandaseparategroundwireisused,itis recommendedthataqualifiedelectricalinstallerdeterminethat
thegroundpathandwiregaugeareinaccordancewithlocal
codes. Ifcodespermitandaseparategroundwireisused,itis
recommendedthataqualifiedelectriciandeterminethatthe groundpathisadequate.
Donotuseanextensioncord. Besurethattheelectricalconnectionandwiresizeareadequate
andinconformancewiththeNationalElectricalCode,ANSI/ NFPA70-latesteditionandalllocalcodesandordinances.
Acopyoftheabovecodestandardscanbeobtainedfrom:
NationalFireProtectionAssociation,OneBatterymarchPark, Quincy,MA02269.
Electrical Connection
To properly install your range, you must determine the type of
electrical connection you will be using and follow the instructions provided for it here.
Range must be connected to the proper electrical voltage and frequency as specified on the model/serial number rating plate. (The model/serial number rating plate is located on the oven frame behind the storage drawer panel.)
When a 4-wire or 3-wire, single phase 120/240-volt, 60 Hz, AC-only electrical supply is available, a 50 amp maximum circuit protection is required (or, if specified on the model/ serial rating plate, when a 4-wire or 3-wire single phase 120/208-volt 60 Hz, AC-only electrical supply is available, a 40 amp maximum circuit protection is required), fused on
both sides of the line.
A time-delay fuse or circuit breaker is recommended. The range can be connected directly to the fused disconnect
(or circuit breaker box) through flexible, armored or nonmetallic sheathed, copper or aluminum cable. See
"Electrical Connection."
Allow 2 to 3 ft of slack in the line so that the range can be moved if servicing is ever necessary.
A UL listed conduit connector must be provided at each end of the power supply cable (at the range and at the junction box).
Wire sizes and connections must conform with the rating of the range (40 amps).
The wiring diagram is located on the underside of the storage drawer or below the warming drawer in a clear plastic bag.
If connecting to a 4-wire system:
This range is manufactured with the ground connected to the
cabinet. The ground must be revised so the green grounding wire of the 4-wire power supply cord is connected to the cabinet. See
"Electrical Connection." Grounding through the neutral conductor is prohibited for new
branch-circuit installations (1996 NEC); mobile homes; and recreational vehicles, or an area where local codes prohibit grounding through the neutral conductor.
When a 4-wire receptacle of NEMA Type 14-50R is used, a matching UL listed, 4-wire, 250-volt, 40 amp, range power supply cord (pigtail) must be used. This cord contains 4 copper conductors with ring terminals or open-end spade terminals with upturned ends, terminating in a NEMA Type 14-50P plug on the supply end.
The fourth (grounding) conductor must be identified by a green or green/yellow cover and the neutral conductor by a white cover. Cord should be Type SRD or SRDT with a UL listed strain relief and be at least 4 ft (1.22 m) long.
4-wire receptacle (14-50R)
The minimum conductor sizes for the copper 4-wire power cord are:
40 amp circuit 2 No.-8 conductors
1 No.-10 white neutral 1 No.-8 green grounding
If connecting to a 3-wire system:
Local codes may permit the use of a UL listed, 3-wire, 250-volt, 40 amp range power supply cord (pigtail). This cord contains 3 copper conductors with ring terminals or open-end spade terminals with upturned ends, terminating in a NEMA Type 10-50P plug on the supply end. Connectors on the appliance end must be provided at the point the power supply cord enters the appliance. This uses a 3-wire receptacle of NEMA Type 10-50R.
3-wire receptacle (10-50R)
Electrical Shock Hazard
Emectricaliy ground range. Failure to follow these instructions can resumt in death,
fire, or electdcam shock.
If codes permit and a separate ground wire is used, it is recommended that a qualified electrical installer determine that the ground path and wire gauge are in accordance with local
codes.
Besurethattheelectricalconnectionandwiresizeareadequate andinconformancewithCSAStandardC22.1,Canadian ElectricalCode,Part1-latestedition,andalllocalcodesand
ordinances.
Acopyoftheabovecodestandardscanbeobtainedfrom:
CanadianStandardsAssociation,178RexdaleBlvd.,Toronto, ONM9W1R3CANADA.
Donotgroundtoagaspipe.
Checkwithaqualifiedelectricalinstallerifyouarenotsure therangeisproperlygrounded.
Donothaveafuseintheneutralorgroundcircuit. Whena4-wire,singlephase120/240-volt,60Hz,AC-only
electricalsupplyisavailable,a50ampmaximumcircuit protectionisrequired(or,ifspecifiedonthemodel/serial ratingplate,whena4-wire,singlephase120/208-volt60Hz, AC-onlyelectricalsupplyisavailable,a40ampmaximum circuitprotectionisrequired),fusedonbothsidesoftheline.
Atime-delayfuseorcircuitbreakerisrecommended. ThisrangeisequippedwithaCSAInternationalCertified
PowerCordintendedtobepluggedintoastandard14-50R wallreceptacle.Besurethewallreceptacleiswithinreachof range'sfinallocation.
Thecooktopsidesoftheslide-inrangefitoverthecutoutedgeof yourcountertop.
_r_.... ........
(57.8 cm_
If you have a square finish (flat) countertop and the opening width is 30" (76.2 cm), no countertop preparation is required.
Formed front-edged countertops must have molded edge shaved flat %" (1.0 cm) from each front corner of opening.
Tile countertops may need trim cut back 3/8"(1.0 cm) from each front corner and/or rounded edge flattened.
\
Do not use an extension cord.
INSTALLATIONINSTRUCTIONS
Remove shipping materials, tape and protective film from range. Keep cardboard bottom under range. Remove oven racks and parts package from inside oven.
2,
Take 4 cardboard corners from the carton. Stack one cardboard corner on top of another. Repeat with the other
2 corners. Place them lengthwise on the floor behind the range to support the range when it is laid on its back. Firmly grasp the range and gently lay it on its back on the cardboard
corners.
3. Pull cardboard bottom firmly to remove.
4. Use an adjustable wrench to loosen the leveling legs.
5. Place cardboard or hardboard in front of range. Stand range back up onto cardboard or hardboard.
If countertop opening width is greater than 30" (76.2 cm), adjust the %" (1.0 cm) dimension.
Countertop must be level. Place level on countertop, first side to side; then front to back. If countertop is not level, range will not
be level. Oven must be level for satisfactory baking performance.
Tip Over Hazard
A child or adult can tip the range and be killed. Connect anti4ip bracket to rear range foot.
Reconnect the antFtip bracket, if the range is moved. Failure to follow these instructions can result in death
or serious burns to children and adults.
Contact a qualified floor covering installer for the best procedure for drilling mounting holes through your type of floor covering. Before moving range, slide range onto shipping base, cardboard
or hardboard.
1. Remove template from the anti-tip bracket kit (found inside the oven cavity).
Loading...