Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.”
These words mean:
You can be killed or seriously injured if you don't immediately
DANGER
WARNING
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can
happen if the instructions are not followed.
follow instructions.
You
can be killed or seriously injured if you don't
instructions.
follow
2
IMPORTANT SAFETY INSTRUCTIONS
Ducted fans must always be vented to the outdoors.
For General Ventilating Use Only. Do Not Use
To Exhaust Hazardous Or Explosive Materials And Vapors.
READ AND SAVE THESE INSTRUCTIONS
To Reduce The Risk Of Fire Or Electric
Shock, Do Not Use This Fan With Any Solid-State Speed
Control Device.
This appliance is not intended for use by people (including
children) whose physical, sensory or mental capacities are
different or impaired or who lack the necessary experience
or knowledge/expertise to do so, unless such persons are
supervised or are trained to operate the appliance by a
person who accepts responsibility for their safety.
3
INSTALLATION REQUIREMENTS
10
"
4
"
" (116.6 cm) max.
30" (76.2 cm) or
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed
here.
Tools Needed
■ Level
■ Drill with 1¼" (3.0 cm), 3/8" (9.5 mm), and 5/16" (7.9mm)
■ Pencil
■ Wire stripper or utility knife
■ Tape measure or ruler
■ Pliers
■ Caulking gun and weatherproof caulking compound
■ Vent clamps
■ Jigsaw or keyhole saw
■ Flat-blade screwdriver
■ Metal snips
■ Phillips screwdriver
Parts needed
■ Home power supply cable
■ 1/2" (1.3 cm) UL listed or CSA approved strain relief
■ 3 UL listed wire connectors
For vented installations, you will also need:
■ 1 wall or roof cap
■ Metal vent system
For non-vented (recirculating) installations, you will also
need:
■ Recirculation Kit - See “Assistance or Service” section to
■ 6" (15.2 cm) dia. round metal vent duct - length required is
Parts Supplied
Remove parts from packages. Check that all parts are included.
■ Hood canopy assembly with blower, light bulbs, and canopy
■ Vent transition with back draft dampers installed
■ Metal grease lter
■ Vent cover support bracket
■ Mounting template
■ 2-piece vent cover
■ Air deector (for non-vented [recirculating] installations only)
■ 2 - 3.5 x 9.5 mm T10 screws
■ 4 - 4.2 x 8 mm T20
■ 6 - 5 x 45 mm mounting screws (for 8 x 40 mm wall anchors)
■ 2 - 8 x 40 mm wall anchors
■ 4 - 10 x 60 mm wall anchors
■ 4 - 5.4 x 75 mm screws (for 10 x 60 mm wall anchors)
■ T10 Torx
■ T20
†®TORX and T20 are trademarks of Acument Intellectual Properties, LLC.
4
Tools and Parts
drill bits
order.
determined by ceiling height.
glass already installed
®†
®†
adapter
Torx® adapter.
®
screws
Location Requirements
IMPORTANT: Observe all governing codes and ordinances.
Have a qualied technician install the range hood. It is the
installer’s responsibility to comply with installation clearances
specied on the model/serial/rating plate. The model/serial/
rating plate is located behind the left lter on the rear wall of the
vent hood.
Canopy hood location should be away from strong draft areas,
such as windows, doors and strong heating vents.
Cabinet opening dimensions that are shown must be used.
Given dimensions provide minimum clearance.
Grounded electrical outlet is required. See “Electrical
Requirements” section.
The canopy hood is factory set for venting through the roof or
wall. For non-vented (recirculating) Installation see “For nonvented (recirculating) installation only” in the “Connect Vent
System” section. Recirculation Kit Part Number W10294733 is
available from your dealer or an authorized parts distributor. All
openings in ceiling and wall where canopy hood will be installed
must be sealed.
For Mobile Home Installations
The installation of this range hood must conform to the
Manufactured Home Construction Safety Standards, Title
24CFR, Part 328 (formerly the Federal Standard for Mobile
Home Construction and Safety, Title 24, HUD, Part 280) or when
such standard is not applicable, the standard for Manufactured
Home Installation 1982 (Manufactured Home Sites, Communities
and Setups) ANSI A225.1/NFPA 501A, or latest edition, or with
local codes.
Minimum distance “X”: 24" (61.0 cm) from electric cooking
surface.
Minimum distance “X”: 30" (76.2 cm) from gas cooking
surfaces.
Suggested maximum distance “X”: 36" (91.4 cm)
The chimneys can be adjusted for different ceiling heights. See
the following chart.
Vented Installations
Min. ceiling heightMax. ceiling height
Electric cooking
7' 1¼" (2.2 m)8' 6" (2.6 m)
surface
Gas cooking
7' 7
surface
Non-Vented (Recirculating) Installations
Min. ceiling heightMax. ceiling height
Electric cooking
7' 3
surface
Gas cooking
7' 9
surface
NOTE: The range hood chimneys are adjustable and designed to
meet varying ceiling or soft heights depending on the distance
“X” between the bottom of the range hood and the cooking
surface. For higher ceilings, a Chimney Extension Kit is available
from your dealer or an authorized parts distributor. The chimney
extension replaces the upper chimney shipped with the range
hood. See the “Assistance or Service” section to order.
2" (5.1 cm) min.
9" (22.9 cm) min.*
Vent and power
supply cable
entry location
17" (43.2 cm)*
Side
cabinet
Centerline
Cooking surface
1
/4" (2.3 m)9' (2.7 m)
5
/16" (2.2 m)8' 915/16" (2.7 m)
5
/16" (2.4 m)9' 315/16" (2.8 m)
Venting Requirements
(Vented models only)
■ Vent system must terminate to the outdoors, except for non-
vented (recirculating) installations.
■ Do not terminate the vent system in an attic or other
enclosed area.
■ Do not use 4" (10.2 cm) laundry-type wall cap.
■ Use metal vent only. Rigid metal vent is recommended.
Plastic or metal foil vent is not recommended.
■ The length of vent system and number of elbows should be
kept to a minimum to provide efcient performance.
For the Most Efcient and Quiet Operation:
■ Use no more than three 90° elbows.
■ Make sure there is a minimum of 24" (61.0 cm) of straight
vent between the elbows if more than 1 elbow is used.
■ Do not install 2 elbows together.
■ Use clamps to seal all joints in the vent system.
■ The vent system must have a damper. If the roof or wall
cap has a damper, do not use the damper supplied with the
range hood.
■ Use caulking to seal exterior wall or roof opening around the
cap.
■ The size of the vent should be uniform.
Cold Weather Installations
An additional back draft damper should be installed to minimize
backward cold airow and a thermal break should be installed
to minimize conduction of outside temperatures as part of the
vent system. The damper should be on the cold air side of the
thermal break.
The break should be as close as possible to where the vent
system enters the heated portion of the house.
Makeup Air
Local building codes may require the use of makeup air systems
when using ventilation systems greater than specied CFM of
air movement. The specied CFM varies from locale to locale.
Consult your HVAC professional for specic requirements in your
area.
Venting Methods
This canopy hood is factory set for venting through the roof or
wall.
A 6" (15.2 cm) round vent system is needed for installation (not
included). The hood exhaust opening is 6" (15.2 cm) round.
NOTE: Flexible vent is not recommended. Flexible vent
creates back pressure and air turbulence that greatly reduce
performance.
Vent system can terminate either through the roof or wall.
To vent through a wall, a 90° elbow is needed.
Rear Discharge
A 90° elbow may be installed immediately above the hood.
5
For Non-Vented (Recirculating) Installations
90 elbow
6 ft (1.8 m)
2 ft
(0.6 m)
Wall cap
If it is not possible to vent cooking fumes and vapors to the
outside, the hood can be used in the non-vented (recirculating)
version, using a charcoal lter and the deector. To order, see
the “Assistance or Service” section.
Roof VentingWall Venting
Non-Vented
(Recirculating)
A. Roof cap
B. 6" (15.2 cm)
round vent
A. Wall cap
B. 6" (15.2 cm)
round vent
A. Deector
B. 6" (15.2 cm)
round vent
Calculating Vent System Length
To calculate the length of the system you need, add the
equivalent feet (meters) for each vent piece used in the system.
Vent Piece6" (15.2 cm) Round
45° elbow2.5 ft
(0.8 m)
90° elbow5.0 ft
(1.5 m)
Maximum equivalent vent length is 35 ft (10.7 m).
Example Vent System
Electrical Requirements
Observe all governing codes and ordinances.
Ensure that the electrical installation is adequate and in
conformance with National Electrical Code, ANSI/NFPA 70
(latest edition), or CSA Standards C22.1-94, Canadian Electrical
Code, Part 1 and C22.2 No. 0-M91 (latest edition) and all local
codes and ordinances.
If codes permit and a separate ground wire is used, it is
recommended that a qualied electrician determine that the
ground path is adequate.
A copy of the above code standards can be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
CSA International
8501 East Pleasant Valley Road
Cleveland, OH 44131-5575
■ A 120 V, 60 Hz, AC only, 15 A fused, electrical circuit is
required.
■ If the house has aluminum wiring, follow the procedure
below:
Connect the aluminum wiring using special connectors
and/or tools designed and UL listed for joining copper to
aluminum.
Follow the electrical connector manufacturer’s recommended
procedure. Aluminum/copper connection must conform with
local codes and industry accepted wiring practices.
■ Wire sizes and connections must conform with the rating of
the appliance as specied on the model/serial/rating plate.
The model/serial/rating plate is located behind the left lter
on the rear wall of the range hood.
■ Wire sizes must conform to the requirements of the National
Electrical Code, ANSI/NFPA 70 (latest edition), or CSA
Standards C22. 1-94, Canadian Electrical Code, Part 1 and
C22.2 No. 0-M91 (latest edition) and all local codes and
ordinances.
The following example falls within the maximum recommended
vent length of 35 ft (10.7 m).
1 - 90° elbow
1 - wall cap
8 ft (2.4 m) straight
= 5.0 ft (1.5 m)
= 0.0 ft (0.0 m)
= 8.0 ft (2.4 m)
Length of system= 13.0 ft (3.9 m)
6
INSTALLATION INSTRUCTIONS
Prepare Location
■ It is recommended that the vent system be installed before
hood is installed.
■ Before making cutouts, make sure there is proper clearance
within the ceiling or wall for exhaust vent.
■ Check your ceiling height and the hood height maximum
before you select your hood.
1. Disconnect power.
2. Determine which venting method to use: roof, wall, or
non-vented.
3. Select a at surface for assembling the range hood. Place
covering over that surface.
WARNING
Excessive Weight Hazard
Use two or more people to move and install
range hood.
Failure to do so can result in back or other injury.
4. Using 2 or more people, lift range hood onto covered
surface.
For wall anchors, drill 7/16" (10 mm) holes at all locations
where wall anchors are being used.
6. For wood, install (2) 5 x 45 mm mounting screws on the top
two fastener locations. Leave a 1/4" (6.4 mm) gap between
the wall and the back of the screw head to slide range hood
into place.
For wall anchors, install the 10 x 60 mm wall anchors and
install (2) 5.4 x 75 mm screws into the top wall anchors.
Tighten until the wall anchors are secure. Back the screws
out 1/4" (6.4 mm).
1⁄4"
(6.4 mm)
Vent Cover Bracket Installation
Attach vent cover bracket to wall ush to the ceiling using (2)
5x45 mm screws. Use the optional wall anchors if needed.
Range Hood Mounting Screws Installation
1. Determine and mark the centerline on the wall where the
canopy hood will be installed (A).
2. Select a mounting height between a minimum of 24"
(61.0cm) for an electric cooking surface, a minimum of
27" (68.6 cm) for a gas cooking surface, and a suggested
maximum of 36" (91.4 cm) above the range to the bottom of
the hood. Mark a reference line on the wall (C).
3. Tape the template in place by aligning the template
centerline with the centerline marked on the wall (A) and
bottom of template with hood bottom line (C).
A
DRILL 2 (TWO) 3/16" PILOT HOLES TH ROUGH STUDS OR REAR WALL SU PPORT
Vertical Centerline
REAR WALL
MOUNTING TEMPLATE
C
L
Horizo ntal Line
B
A. Centerline
B. Fastener locations
C. Mounting height reference (hood bottom line)
4. Mark centers of the fastener locations through the template
to the wall.
IMPORTANT: All canopy mounting screws must be installed
into wood where possible. If there is no wood to screw into,
additional wall framing supports may be required, or use the
(4) 10 x 60 mm wall anchors and 5.4 x 75 mm screws.
Remove the template.
5. For wood, drill 3/16" (4.8 mm) pilot holes at all locations
where screws are being installed into wood.
Installation Height
ALIGN BOTTOM EDGE
WITH PENCIL LINE
INDICATING BO TTOM
OF TH E HOOD
C
A
B
C
A. Ceiling
B. Wall
C. Centerline
Complete Preparation
1. Determine and make all necessary cuts in the wall for the
vent system. Install the vent system before installing the
hood. See “Venting Requirements” section.
2. Determine the required height for the home power supply
cable and drill a 1¼" (3.2 cm) hole at this location.
3. Run the home power supply cable according to the National
Electrical Code or CSA Standards and local codes and
ordinances. There must be enough 1/2" (1.3 cm) conduit and
wires from the fused disconnect (or circuit breaker) box to
make the connection in the hood’s electrical terminal box.
NOTE: Do not reconnect power until installation is complete.
4. Use caulk to seal all openings.
7
Install Range Hood
A
B
C
A
B
1. Remove screws from wooden shipping supports. Properly
dispose of shipping materials.
2. Using 2 or more people, hang range hood on 2 mounting
screws through the mounting slots on back of hood.
For non-vented (recirculating) installation only:
1. Assemble the air deector with the duct cover bracket using
(4) 4.2 x 8 mm T20
®
screws. Use a T20® Torx® drive (or T20®
adapter provided) to tighten.
A
B
C
A. Assembly screws
B. Air deector
C. Duct cover bracket
2. Measure from the bottom of the air deector to the bottom of
the hood outlet.
A
B
A. Mounting screws
B. Mounting slots
C. Lower mounting screws
3. Remove the grease lter. See “Range Hood Care” section.
4. Level the range hood and tighten upper mounting screws.
5. Install (2) 5 x 45 mm #2 Phillips lower mounting screws and
tighten. Use the optional wall anchors if needed.
Connect Vent System
1. Install vent transition (A) on top of hood (if removed for
shipping) with (2) 3.5 x 9.5 mm T10 sheet metal screws. Use
T10 Torx
®
drive (or T10 adapter provided) to tighten.
C
D
X
E
A. Air deector
B. Vent clamp
C. X = length to cut vent duct
D. Vent duct
E. Exhaust outlet
3. Cut the duct to the measured size “X.”.
4. Remove the air deector.
5. Slide the duct onto the bottom of the air deector.
6. Place the assembled air deector and duct over the exhaust
outlet from the hood.
7. Reassemble the air deector to the duct cover bracket with
the 4 assembly screws.
8. Seal connections with vent clamps.
A. Vent transition
B. 3.5 x 9.5 mm screw location
For vented installations only:
1. Fit vent system over transition piece.
3. Check that back draft dampers work properly.
2. Seal connection with clamps.
8
Make Electrical Connection
A
B
C
A
B
C
D
F
E
A
B
C
D
6. Use UL listed wire connectors and connect white wires (E)
together.
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
1. Disconnect power.
2. Remove terminal box cover (Unscrew “C”).
3. Remove the knockout in the terminal box cover and install a
UL listed or CSA approved 1/2" (1.3 cm) strain relief.
WARNING
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire
in terminal box.
Failure to do so can result in death or electrical shock.
7. Connect green (or bare) ground wire from home power
supply to yellow-green ground wire (F) in terminal box using
UL listed wire connectors.
8. Tighten strain relief screw.
9. Install terminal box cover.
10. Check that all light bulbs are secure in their sockets.
11. Reconnect power.
Install Vent Covers
When using both upper and lower vent covers, push lower
cover down onto hood and lift upper cover to ceiling. Install with
(2) 4.2x8 mm T20
adapter provided) to tighten.
NOTE: For vented installations, upper vent cover may be
reversed to hide slots.
®
screws using a T20® Torx® drive (or T20®
A. Knockout
B. Terminal box cover
C. Screws (7)
4. Run home power supply cable through strain relief into
terminal box.
A. 4.2 x 8 mm screws
B. Bracket
C. Upper vent cover
D. Lower vent cover
A. Home power supply cable
B. UL listed or CSA approved
strain relief
C. Black wires
D. UL listed wire connectors
E. White wires
F. Green (or bare) and yellow green
ground wires
5. Use UL listed wire connectors and connect black wires (C)
together.
9