PRODUCT MODEL NUMBERS
WVW75UC0D WVW75UC6D
ELECTRICAL REQUIREMENTS
• A 120 Volt, 60 Hz., AC only, 15-amp, fused electrical circuit is required.
VENTING REQUIREMENTS
This canopy hood is factory set for venting through the roof or wall.
A 6" (15.2 cm) round vent system is needed for installation (not included). The
hood exhaust opening is 6" (15.2 cm) round.
NOTE: Flexible vent is not recommended. Flexible vent creates back pressure and
air turbulence that greatly reduce performance.
Vent system can terminate either through the roof or wall. To vent through a
wall, a 90° elbow is needed.
Rear discharge
A 90° elbow may be installed immediately above the hood.
For Non-Vented (recirculating) Installations
If it is not possible to vent cooking fumes and vapors to the outside, the hood
can be used in the non-vented (recirculating) version, fitting a charcoal filter and
the deflector. Fumes and vapors are recycled through the top grille.
30" and 36" (76.2 cm and 91.4 cm) Wall-Mount
Canopy Range Hood
Because Whirlpool Corporation policy includes a continuous commitment to improve our
products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. W10674116A
12/12/14
Page 1 of 2
Calculating Vent System Length
To calculate the length of the system you need, add the equivalent feet
(meters) for each vent piece used in the system.
Vent Piece Round
45° elbow 2.5 ft (0.8 m)
90° elbow 5.0 ft (1.5 m)
Maximum equivalent vent length is 35 ft (10.7 m).
PRODUCT DIMENSIONS
Example vent system
The following example falls within the maximum recommended vent
length of 35 ft (10.7 m).
1 - 90° elbow
1 - wall cap
8 ft (2.4 m) straight
= 5.0 ft (1.5 m)
= 0.0 ft (0.0 m)
= 8.0 ft (2.4 m)
Length of system = 13.0 ft (3.9 m)
Roof Venting Wall Venting Non-vented
A
B
(recirculating)
A
B
B
A
90 elbow
2 ft
(0.6 m)
6 ft (1.8 m)
Wall cap
A. Roof cap
B. 6" (15.2 cm)
round vent
10⁷⁄₈"
(27.6 cm)
A. Wall cap
B. 6" (15.2 cm)
round vent
13³⁄₁₆"
(33.5 cm)
A. Deflector
B. 6" (15.2 cm)
round vent
**27¹⁄₈" (68.9 cm) min.
**41¹⁄₈" (104.5 cm) max.
*27¹⁄₈" (68.9 cm) min.
*45¹⁄₂" (115.6 cm) max.
17³⁄₁₆" (43.7 cm)
20"
(50.8 cm)
30" (76.2 cm) or
36" (91.4 cm)
*For non-vented (recirculating) installations
**For vented installations
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. W10674116A
12/12/14
Page 2 of 2
CABINET DIMENSIONS
IMPORTANT:
Minimum distance “X”: 24" (61.0 cm) from electric cooking
surface
Minimum distance “X”: 27" (68.6 cm) from gas cooking
surface
Suggested maximum distance “X”: 36" (91.4 cm)
The chimneys can be adjusted for different ceiling heights. See
the following chart.
Vented Installations
Min. ceiling height Max. ceiling height
Electric cooking surface 7' 4" (2.23 m) 9' 5" (2.87 m)
Gas cooking surface 7' 7" (2.31 m) 9' 5" (2.87 m)
Non-vented (recirculating) Installations
Min. ceiling height Max. ceiling height
Electric cooking surface 7' 4" (2.23 m) 9' 9" (2.97 m)
Gas cooking surface 7' 7" (2.31 m) 9' 9" (2.97 m)
*NOTE: The range hood chimneys are adjustable and designed to
meet varying ceiling or soffit heights depending on the distance “X”
between the bottom of the range hood and the cooking surface. For
higher ceilings, a Stainless Steel Chimney Extension Kit Part Number
W10294735 is available from your dealer or an authorized parts
distributor. The chimney extension replaces the upper chimney
shipped with the range hood.
10" (25.4 cm) min.
13" (33.0 cm) max.
9¹⁄₂" (24.1 cm)
10" (25.4 cm) min.
13" (33.0 cm) max.
Side
cabinet
bottom of
to cooking
30" (76.2 cm) or
36" (91.4 cm)
“X”
canopy
surface
2" (5.1 cm) min.
9" (22.9 cm) min.*
20" (50.8 cm)* min.
Centerline
Cooking surface
*For non-vented (recirculating) installations
Vent and power
supply cable
entry location
Side
cabinet