Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.”
These words mean:
You can be killed or seriously injured if you don't immediately
DANGER
WARNING
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can
happen if the instructions are not followed.
State of California Proposition 65 Warnings:
WARNING: This product contains one or more chemicals known to the State of California to cause cancer.
WARNING: This product contains one or more chemicals known to the State of California to cause birth defects or other
reproductive harm.
follow instructions.
You
can be killed or seriously injured if you don't
instructions.
follow
3
IMPORTANT SAFETY INSTRUCTIONS
READ AND SAVE THESE INSTRUCTIONS
4
INSTALLATION REQUIREMENTS
Tools and Parts
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed
here.
Tools needed
■ Drill
4
■ 1¹⁄
" (3.0 cm) drill bit
8
■ ¹⁄
" (3.0 mm) drill bit for pilot holes
■ Pencil
■ Wire stripper or utility knife
■ Tape measure or ruler
■ Caulking gun and weatherproof caulking com"und
■ Flat-blade screwdriver
■ Phillips screwdriver
■ Saber or keyhole saw
■ Metal snips
Parts supplied
Remove parts from package. Check that all parts are included.
■ #8-18 x 1" (4.2 mm x 25 mm) flat-head screws (2)
■ #8-18 x
■ Drywall anchors (2)
■ Mounting brackets (2)
9
■
/64" x 13/64" (3.5 mm x 5 mm) T10-head screws (2)
■ T10 TORX
■ 3
■ Regular air damper (1)
Parts needed
■ Wall or roof cap with damper to match vent system
■ 3 - UL Listed wire connectors
■ Vent clamps/duct tape as required
For 7" (17.8 cm) round vented installations:
■ 7" (17.8 cm) round metal vent system
For 3¹⁄4" x 10" (8.3 cm x 25.4 cm) rectangular vented
installations:
■ 3¹⁄
For non-vented (recirculation) installations:
■ Charcoal filter kit. For information on ordering, see the
“Accessories” section.
5
/8" (4.2 mm x 16 mm) truss-head screws (4)
®†
adapter (1)
1
/4" x 10" (8.3 cm x 25.4 cm) rectangular air transition (1)
4
" x 10" (8.3 cm x 25.4 cm) rectangular metal vent system
Location Requirements
IMPORTANT: Observe all governing codes and ordinances.
■ It is the installer’s responsibility to comply with installation
clearances specified on the model/serial/rating plate. The
model/serial/rating plate is located inside the range hood on
the left wall.
■ Range hood location should be away from strong draft areas,
such as windows, doors, and strong heating vents.
■ Cabinet opening dimensions that are shown must be used.
Given dimensions provide minimum clearance. Consult the
cooktop/range manufacturer installation instructions before
making any cutouts.
■ This range hood is recommended for use with cooktops with
a maximum total rating of 55,000 BTUs or less.
■ Grounded electrical outlet is required. See the “Electrical
Requirements” section.
■ All openings in ceiling and wall where range hood will be
installed must be sealed.
■ These range hoods are factory set for vented installations.
Models that are capable of being installed as non-vented
(recirculating) require charcoal filters. See the “Accessories”
section to order charcoal filter kit.
For Mobile Home Installations
The installation of this range hood must conform to the
Manufactured Home Construction Safety Standards, Title 24
CFR, Part 328 (formerly the Federal Standard for Mobile Home
Construction and Safety, title 24, HUD, Part 280) or when such
standard is not applicable, the standard for Manufactured Home
Installation 1982 (Manufactured Home Sites, Communities and
Setups) ANSI A225.1/NFPA 501A, or latest edition, or with local
codes.
Product Dimensions
C
B
A
I
I
H
A. 619/54" (16 cm)
B. 2" (5 cm)
C. 825/64" (21.3 cm)
D. 1" (2.54 cm)
E. 832/32" (22.8 cm)
F. 1911/16" (50 cm)
G. 11/2" (3.8 cm)
H. 36" (91.4 cm)
30" (76.2 cm)
I. 55/64" (2.2 cm)
Centerline
G
D
E
F
†®TORX is a registered trademark of Acument Intellectual Properties, LLC.
5
Installation Clearances
B
A
E
■ Do not install 2 elbows together.
■ Use clamps or duct tape to seal all joints in the vent system.
■ The vent system must have a damper. If roof or wall cap has
a damper, do not use damper supplied with the range hood.
■ Use caulking to seal exterior wall or roof opening around
the cap.
C
Cold Weather Installations
An additional back draft damper should be installed to minimize
backward cold air flow and a thermal break should be installed
D
to minimize conduction of outside temperatures as part of the
vent system. The damper should be on the cold air side of the
thermal break.
The break should be as close as possible to where the vent
system enters the heated portion of the house.
Makeup Air
Local building codes may require the use of makeup air systems
when using ventilation systems greater than specified CFM of
air movement. The specified CFM varies from locale to locale.
Consult your HVAC professional for specific requirements in your
area.
Venting Methods
A. 18" (45.7 cm) min. clearance - upper cabinet to countertop
B. 24" (61.0 cm) minimum - bottom of range hood to cooking surface
C. 30" (76.2 cm) min. cabinet opening width for 30" (76.2 cm) models
36" (91.4 cm) min. cabinet opening width for 36" (91.4 cm) models
D. 12" (30.5 cm) minimum cabinet depth
E. 36" (91.4 cm) base cabinet height
Venting Requirements
■ This range hood is factory set to exhaust the air to
the outside through the wall or the roof. A non-vented
(recirculating) installation will require a Charcoal Filter Kit.
See the “Accessories” section for ordering information.
■ Vent system must terminate to the outdoors, except for
nonvented (recirculating) installations.
■ Do not terminate the vent system in an attic or other
enclosed area.
■ Do not use a 4" (10.2 cm) laundry-type wall cap.
■ Use a 7" (17.8 cm) round metal vent or a 3¹⁄
(8.3 cm x 25.4 cm) rectangular metal vent, depending
on your installation requirements. Rigid metal vent
is recommended. Plastic or metal foil vent is not
recommended.
■ The length of vent system and number of elbows should be
kept to a minimum to provide efficient performance.
For the most efficient and quiet operation:
■ Use no more than three 90° elbows.
■ Make sure there is a minimum of 24" (61 cm) of straight vent
between the elbows if more than 1 elbow is used.
4
" x 10"
Vent system can terminate either through the roof or wall. Use
3¹⁄4" x 10" (8.3 cm x 25.4 cm) rectangular with a maximum vent
length of 35 ft (10.7 m) or 7" (17.8 cm) or larger round vent with
a maximum length of 50 ft (15.2 m) for vent system.
NOTE: Flexible vent is not recommended. Flexible vent creates
both back pressure and air turbulence that greatly reduce
performance.
Roof VentingWall VentingRecirculating
B
A
A
C
C
E
B
D
C
A. 7" (17.8 cm) round vent through roof or 31⁄4" x 10"
(8.3 cm x 25.4 cm) rectangular vent through the roof
or wall (purchased separately)
B. Roof/Wall cap with damper (purchased separately)
C. 24" (61.0 cm) min. above the cooking surface
D. Charcoal Filter Kit (purchased separately)
E. Recirculating grid
6