Whirlpool WVI51UC6LS, WVI51UC0LS PRODUCT SPECIFICATIONS

0 (0)
Whirlpool WVI51UC6LS, WVI51UC0LS PRODUCT SPECIFICATIONS

30" (76.2 cm) and 36" (91.4 cm) Island-Mount Range Hood

PRODUCT MODEL NUMBERS

WVI51UC0L WVI51UC6L

ELECTRICAL REQUIREMENTS

A 120 volt, 60 Hz., AC only, 15-amp, fused electrical circuit is required.

CABINET DIMENSIONS

B

CD

A

A.Countertop height

B.Hood height from ceiling to bottom

of the range hood filter surface: D-A-C=B

C.Hood height: 24" (61 cm) min. from electric cooking surface, 27" (68.6 cm) min. from gas cooking surface, suggested 36" (91.4 cm) max.

D. Ceiling height

* For non-vented (recirculating) installations

IMPORTANT:

 

 

 

Minimum distance “X”: 24" (61

from electric cooking surface

Minimum distance “X”: 27" (68

cm) from gas cooking surface

Suggested maximum distance

36" (91.4 cm)

 

The chimneys can be adjusted for different ceiling heights. See the

following chart.

 

 

 

 

Min. ceiling height

Max. ceiling height

 

 

 

Electric cooking surface

7' 8" (2.34 m)

9' 10" (3 m)

Gas cooking surface

7' 11" (2.41 m)

9' 10" (3 m)

Non-Vented (Recirculating) Installations

 

 

 

 

Min. ceiling height

Max. ceiling height

 

 

 

Electric cooking surface

7' 8" (2.34 m)

10' 3" (3.12 m)

Gas cooking surface

7' 11" (2.41 m)

10' 3" (3.12 m)

NOTE: The range hood chimneys are adjustable and designed to meet varying ceiling or soffit heights depending on the distance “C” between the bottom of the range hood and the cooking surface. For higher ceilings, a Stainless Steel Chimney Extension Kit is available from your dealer or an authorized parts distributor. The chimney extension replaces the upper chimney shipped with the range hood.

PRODUCT DIMENSIONS

AB

C

D E

A.121/8"(30.8 cm)

B.133/16"(33.5 cm)

C.*285/8"(72.7 cm) min. 493/8"(125.4 cm) max. **281/16"(71.3 cm) min. 441/2"(113.1 cm)

max. D. 2511/16"(65.3 cm)

E.30"(76 cm) or 36"(91.2 cm)

* For non-vented (recirculating) installations

**For vented installations.

VENTING REQUIREMENTS

Vent system must terminate to the outdoors except for non-vented (recirculating) installations.

Do not terminate the vent system in an attic or other enclosed area.

Do not use 4" (10.2 cm) laundry-type wall cap.

metal foil vent is not recommended.

The length of vent system and number of elbows should be kept to a minimum to provide efficient performance.

For the Most Efficient and Quiet Operation:

Use no more than three 90° elbows.

Make sure there is a minimum of 24" (61 cm) of straight vent between the elbows if more than 1 elbow is used.

Do not install 2 elbows together.

Use clamps to seal all joints in the vent system.

The vent system must have a damper. If the roof or wall cap has a damper, do not use the damper supplied with the range hood.

Use caulking to seal exterior wall or roof opening around the cap.

The size of the vent should be uniform.

Because Whirlpool Corporation includes a continues commitment to improve our products, we reserve the right to change materials and specifications without notice.

Dimensions are for planning purposes only. For complete details, see Installation

Page 1 of 4

Instructions packed with product. Specifications subject to change without notice.

 

VENTING METHODS

This island hood is factory set for venting through the roof or wall.

A 6" (15.2 cm) round vent system is needed for installation (not included). The hood exhaust opening is 6" (15.2 cm) round.

NOTE: Flexible vent is not recommended. Flexible vent creates back pressure and air turbulence that greatly reduce performance.

Vent system can terminate either through the roof or wall. To vent through a wall, a 90° elbow is needed.

Rear Discharge

A 90° elbow may be installed immediately above the hood.

For Non-Vented (Recirculating) Installations

If it is not possible to vent cooking fumes and vapors to the outside, the hood can be used in the non-vented (recirculating) version, fitting a

charcoal filter and the deflector. Fumes and vapors are recycled through the top grille.

Non-Vented (Recirculating)

A

B

Roof Venting

A

B

A.

Deflector

A.

Roof cap

B.

6" (15.2 cm) round vent

B.

6" (15.2 cm) round vent

Calculating Vent System Length

To calculate the length of the system you need, add the equivalent feet (meters) for each vent piece used in the system.

Vent Piece

6" (15.2 cm) Round

45° elbow

2.5 ft (0.8 m)

90° elbow

5 ft (1.5 m)

Maximum equivalent vent length is 35 ft (10.7 m).

Example Vent System

90 elbow

 

 

6 ft (1.8 m)

 

 

 

Wall cap

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2 ft

(0.6 m)

The following example falls within the maximum recommended vent length of 35 ft (10.7 m).

1

- 90° Elbow

= 5 ft (1.5 m)

1

- Wall cap

= 0 ft (0 m)

8 ft (2.4 m) straight

= 8 ft (2.4 m)

 

 

Length of system

= 13 ft (3.9 m)

Because Whirlpool Corporation includes a continues commitment to improve our products, we reserve the right to change materials and specifications without notice.

Dimensions are for planning purposes only. For complete details, see Installation

Page 2 of 4

Instructions packed with product. Specifications subject to change without notice.

 

Loading...