Whirlpool WPWADRGW249 Dimension manual

29" and 27" Wide Gas Dryers
29
"
27"
3"/3"
(140 mm/0 mm)
PRODUCT MODEL NUMBERS
WGD4890B, WGD4995E, WGD4890B, WGD4985E
29" Wide Models – Dryer Dimensions
223/4"
(578 mm)
13
/4"
(349 mm)
273/4"*
(705 mm)
26"**
(660 mm)
273/4"*
(705 mm)
26"**
(660 mm)
41
(1054 mm)
11/2"
(38 mm)
A
411/2"
(1054 mm)
/2"
29"
(737 mm)
29"
(737 mm)
27" Wide Models – Dryer Dimensions
223/4"
(578 mm)
133/4"
(349 mm)
291/2"
(749 mm)
/
(749 mm)
B
43"
(1092 mm)
11/2"
(38 mm)
A
43"
(1092 mm)
27"
(686 mm)
(686 mm)
NOTE: Leveling legs should be 1/2" (13 mm) (to match height of
3.6 cu. ft. capacity washer) or 1½" (38 mm) (to match height of
3.8 cu. ft. capacity washer).
Installation Spacing
14" max. (356 mm)
51/2"/0"
(25 mm/0 mm)
1"/0"
/2"
(13 mm)
B
18"/18"
(457 mm/
457 mm)
1"/1"
(25 mm/
25 mm)
(76 mm/76 mm)
48 in.2/48 in.
24 in.
3"/3"
(76 mm/76 mm)
* 6.5 or 7.0 cu. ft. capacity models ** 6.0 cu. ft. capacity models
Installation spacing for recessed area or closet
The dimensions shown are for the minimum spacing allowed.
■ Additional spacing should be considered for ease of installation and
servicing.
■ Additional clearances might be required for wall, door, and oor
(310 cm2/ 310 cm
2
/24 in.
(155 cm2/
155 cm2)
2
2
)
2
moldings.
■ Additional spacing of 1" (25 mm) on all sides of the dryer is
recommended to reduce noise transfer.
■ For closet installation, with a door, minimum ventilation openings in
the top and bottom of the door are required. Louvered doors with equivalent ventilation openings are acceptable.
■ Companion appliance spacing should also be considered.
■ Special provisions must be made in mobile homes to introduce outside
air into the dryer. The opening (such as a nearby window) should be at least twice as large as the dryer exhaust opening.
11/2"
(38 mm)
B
A. Wide opening side-swing door B. Wide opening hamper door
W10617665C
02/2016
INSTALLATION REQUIREMENTS
GAS SUPPLY REQUIREMENTS
Gas supply: This dryer is equipped for use with Natural gas. Dryer can be converted to L.P. gas. When rigid pipe is used it should be 1/2" IPS. When acceptable to the gas supplier and local codes, 3/8" approved tubing may be used for lengths under 20 ft (6.1 m). For lengths over 20 ft (6.1 m), larger tubing should be used. Pipe-joint compounds resistant to the action of L.P. gas must be used. An individual manual shutoff valve must be installed within 6 ft (1.8 m) of the dryer in accordance with the National Fuel Gas Code ANSI Z223.1.
ELECTRICAL REQUIREMENTS
A 120-volt, 60 Hz, AC-only, 15 or 20 amp fused electrical supply is required. A time-delay fuse or circuit breaker and a separate circuit are recommended.
WATER (STEAM MODELS ONLY) REQUIREMENTS
The dryer must be connected to the cold water faucet using new inlet hoses. Do not use old hoses. Do not overtighten. Damage to the coupling can result.
VENTING REQUIREMENTS
Exhaust venting: Exhaust your dryer to the outside. 4" (102 mm)
diameter vent is required. Rigid or exible metal exhaust vent must be used. Do not use plastic or metal foil vet. Exhaust hood must be at least 12" (305 mm) from the ground or any object that may be in the path of the exhaust.
Exhaust hoods:
Recommended Styles:
Louvered Hood
Box Hood
Acceptable Style:
Angled Hood
Determine vent path:
■ Select route that will provide straightest and most direct
path outdoors.
■ Plan installation to use fewest number of elbows and turns.
■ When using elbows or making turns, allow as much room
as possible.
■ Bend vent gradually to avoid kinking.
■ Use as few 90° turns as possible.
Determine vent length and elbows needed for best drying performance:
■ Use following Vent System Chart to determine type of vent
material and hood combinations acceptable to use.
The “Vent System Chart” provides venting requirements that will help achieve best drying performance.
Vent System Chart
Number of 90° turns or elbows
0
1
2
3
4
NOTE: Side and bottom exhaust installations for 27" wide
models have a 90º turn inside the dryer. To determine maximum exhaust length, add one 90º turn to the chart.
Type
of vent
Rigid metal
Rigid metal
Rigid metal
Rigid metal
Rigid metal
Box/louvered
hoods
64 ft. (20 m)
54 ft. (16.5 m)
44 ft. (13.4 m)
35 ft. (10.7 m)
27 ft. (8.2 m)
Angled
hoods
58 ft. (17.7 m)
48 ft. (14.6 m)
38 ft. (11.6 m)
29 ft. (8.8 m)
21 ft. (6.4 m)
Vent System Chart
(29" Wide Long Vent Models Only)
Number of
90° turns
or elbows
0 Rigid metal 120 ft. (36.6 m)
1
2
3
Type
of vent
Rigid metal
Rigid metal
Rigid metal
Box/louvered, or
Angled hoods
110 ft. (33.5 m)
100 ft. (30.5 m)
90 ft. (27.4 m)
NOTE: Do not use vent runs longer than those specied in Vent System Chart. Exhaust systems longer than those specied will:
■ Shorten life of dryer.
■ Reduce performance, resulting in longer drying times
and increased energy usage.
Because Whirlpool Corporation policy includes a continuous commitment to improve Dimensions are for planning purposes only. For complete details, see Installation our products, we reserve the right to change materials and specications without notice. Instructions packed with product. Specications subject to change without notice.
4
5 70 ft. (21.3 m)Rigid metal
Rigid metal
80 ft. (24.4 m)