Whirlpool WOD51ES4EW, WOS51ES4EB, KODC304EBL, WOD51ES4ES, KODC304EWH Installation Instructions

INSTALLATION INSTRUCTIONS
24" (61.0 CM) ELECTRIC SINGLE AND DOUBLE
BUILT-IN OVEN
INSTRUCTIONS D’INSTALLATION
FOUR ENCASTRÉ SIMPLE ET DOUBLE
ÉLECTRIQUE DE 24" (61,0 CM)
Table of Contents/Table des matières
BUILT-IN OVEN SAFETY .......................................................... 1
INSTALLATION REQUIREMENTS .......................................... 2
INSTALLATION INSTRUCTIONS ........................................... 4
SÉCURITÉ DU FOUR ENCASTRÉ ........................................ 8
EXIGENCES D’INSTALLATION ............................................. 8
INSTRUCTIONS D’INSTALLATION. .................................... 11
BUILT-IN OVEN SAFETY
IMPORTANT:
Save for local electrical inspector’s use.
IMPORTANT :
À conserver pour consultation par l’inspecteur local des installations électriques.
W10758285A
INSTALLATION REQUIREMENTS
A
B
Tools and Parts
Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here.
Tools Needed
Phillips screwdriver
Measuring tape
Level
Parts Needed
UL-listed or CSA-approved conduit connector
UL-listed wire connectors
Parts Supplied
Four# 8-14 x 1" screws
Right and left side trim
Bottom vent (supplied on some models)
Bottom vent trim
Two # 8-18 x ³⁄8" screws – bottom vent
Check local codes. Check existing electrical supply. See “Electrical Requirements.”
It is recommended that all electrical connections be made by a licensed, qualified electrical installer.
Hand or electric drill (for
wall cabinet installations)
1" (25 mm) drill bit (for wall
cabinet installations)
Product Dimensions – Single Oven
E
D
A. 22³⁄8" (56.8 cm) max. recessed width B. 29" (73.7 cm) max. overall height C. 23³⁄4" (60.3 cm) overall width D. 23" (58.4 cm) max. recessed depth E. 27¹⁄2" (69.9 cm) recessed height
C
B
Cabinet Dimensions – Single Oven
Single Oven Undercounter (without cooktop installed above)
A
Location Requirements
IMPORTANT: Observe all governing codes and ordinances.
Cabinet opening dimensions that are shown must be used.
Given dimensions provide minimum clearance with oven.
Recessed installation area must provide complete
enclosure around the recessed portion of the oven.
Grounded electrical supply is required. See “Electrical
Requirements” section.
Electrical supply junction box should be located 3"
(7.6 cm) maximum below the support surface when the oven is installed in a wall cabinet. A 1" (2.5 cm) minimum diameter hole should have been drilled in right rear or the left rear corner of the support surface to pass the appliance cable through to the junction box.
NOTE: For undercounter installation, it is recommended
that the junction box be located in the adjacent right or left cabinet. If you are installing the junction box on rear wall behind oven, the junction box must be recessed and located in the upper or lower right or left corner of the cabinet; otherwise, the oven will not t into the cabinet opening.
Oven support surface must be solid, level, and ush with
bottom of cabinet cutout. Floor must be able to support a single oven weight of 140 lbs (63.5 kg) or a double oven weight of 245 lbs (111.1 kg).
Undercounter Installation (with cooktop installed above):
Ovens approved for this type of installation have an approval label located on the top of the oven. Refer to undercounter installation instructions for cutout dimensions and approved oven cooktop combinations (separate sheet).
E
D
A. 24" (61 cm) min. cabinet width B. 1¹⁄2" (3.8 cm) min. top of cutout
to underside of countertop C. 5¹⁄4" (13.3 cm) bottom of cutout to floor D. 225⁄8" (57.5 cm) cutout width E. 27³⁄4" (70.5 cm) min. cutout height
C
2
Single Oven Installed in Cabinet
A
A
E
Cabinet Dimensions – Double Oven
Double Oven Installed in Cabinet
B
B
F
D
E
A. 24" (61 cm) min. cabinet width B. 1" (2.5 cm) top of cutout to bottom
of upper cabinet door
C. 32" (81.3 cm) bottom of cutout
to floor D. 225⁄8" (57.5 cm) cutout width E. 1¹⁄2" (3.8 cm) min. bottom of cutout
to top of cabinet door F. 27³⁄4" (70.5 cm) min. cutout height
Product Dimensions – Double Oven
A
F
D
C
E
C
A. 24" (61 cm) min. cabinet width B. 1" (2.5 cm) top of cutout to bottom of upper
cabinet door C. 14³⁄4" (37.5 cm) bottom of cutout to floor D. 225⁄8" (57.5 cm) cutout width E. 1¹⁄2" (3.8 cm) min. bottom of cutout to top
of cabinet door F. 49³⁄4" (126.4 cm) min. cutout height
Cabinet Side View – Double or Single Oven
A
B
B
E
D
A. 23¹⁄4" (59.1 cm) min. cutout depth B. 23" (58.4 cm) recessed oven depth
D
A. 22³⁄8" (56.8 cm) max. recessed width B. 51" (129.5 cm) max. overall height C. 23³⁄4" (60.3 cm) overall width D. 23" (58.4 cm) max. recessed depth E. 49¹⁄2" (125.7 cm) recessed height
C
C. Oven front D. Recessed oven E. Cabinet
C
3
Electrical Requirements
If codes permit and a separate ground wire is used, it is recommended that a qualied electrical installer determine that the ground path and wire gauge are in accordance with local codes.
Check with a qualied electrical installer if you are not sure the oven is properly grounded.
This oven must be connected to a grounded metal, permanent wiring system.
Be sure that the electrical connection and wire size are adequate and in conformance with the National Electrical Code, ANSI/NFPA 70 – latest edition or CSA Standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No. O-M91 – latest edition, and all local codes and ordinances.
A copy of the above code standards can be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
CSA International
8501 East Pleasant Valley Road
Cleveland, OH 44131-5575
Electrical Connection
To properly install your oven, you must determine the type of electrical connection you will be using and follow the instructions provided for it here.
Oven must be connected to the proper electrical voltage
and frequency as specied on the model/serial number rating plate. The model/serial number rating plate is located on the right mounting rail. See the following illustration.
A
A
Single oven
A. Model/serial/rating plate
Models rated from 7.3 to 9.6 kW at 240 volts (5.5 to
7.2 kW at 208 volts) require a separate 40-amp circuit. Models rated at 7.2 kW and below at 240 volts (5.4 kW and below at 208 volts) require a separate 30-amp circuit.
A time-delay fuse or circuit breaker is recommended.
Connect directly to the fused disconnect (or circuit breaker
box) through exible, armored, or nonmetallic sheathed, copper cable (with grounding wire). See “Make Electrical Connection” section.
Flexible cable from the oven should be connected directly
to the junction box.
Fuse both sides of the line.
Do not cut the conduit. The length of conduit provided
is for serviceability of the oven.
A UL-listed or CSA-approved conduit connector must
be provided.
Double oven
A. Model/serial/rating plate
If the house has aluminum wiring, follow the procedure
below:
1. Connect a section of solid copper wire to the pigtail
leads.
2. Connect the aluminum wiring to the added section
of copper wire using special connectors and/or tools designed and UL listed for joining copper to aluminum.
Follow the electrical connector manufacturer’s recommended procedure. Aluminum/copper connection must conform with local codes and industry-accepted wiring practices.
INSTALLATION
INSTRUCTIONS
Prepare Built-In Oven
1. Decide on the nal location for the oven. Locate existing
wiring to avoid drilling into or severing wiring during installation.
WARNING
Excessive Weight Hazard
Use two or more people to move and install oven.
Failure to do so can result in back or other injury.
2. To avoid oor damage, set the oven onto cardboard prior
to installation. Do not use handle or any portion of the front frame for lifting.
On models with shipping feet attached: To avoid product damage, do not remove the shipping feet
at the front lower corners of the oven. The shipping feet will protect the lower oven trim until the oven is inserted into cabinet.
3. Remove the shipping materials and tape from the oven.
4. Remove the hardware package from inside the bag
containing literature.
5. Remove and set aside racks and other parts from inside
the oven.
6. Move the oven and cardboard close to the oven’s nal
location.
Remove Oven Door(s)
IMPORTANT: Use both hands to remove oven doors.
1. Open the oven door.
2. Locate the oven door latches in both corners of the oven
door, and rotate the latches forward to the unlocked position.
A
B
A. Oven door latch in locked
position
A. Oven door latch in unlocked
position
4
A
(1.3 cm)
(1.3 cm)
A
D
C
3. Grasp the edges of the oven door with both hands and close
the oven door until it will no longer close. Lift and pull oven door toward you and remove. Set the oven door aside on a covered work surface.
Electrical Connection Options Chart
If your home has: Go to section:
4-wire
4-Wire Cable from Home Power Supply
Make Electrical Connection
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Use 8 gauge solid copper wire.
Electrically ground oven.
Failure to follow these instructions can result in death, fire, or electrical shock.
3-wire
½"
3-Wire Cable from Home Power Supply
½"
4-Wire Cable from Home Power Supply
IMPORTANT: Use the 4-wire cable from home power supply
in the U.S. where local codes do not allow grounding through neutral, New Branch circuit installations (1996 NEC), mobile homes and recreational vehicles, new construction and in Canada.
B
E
F
G
H
I
The oven is manufactured with a neutral (white) power supply wire and a cabinet-connected green (or bare) ground wire twisted together.
1. Disconnect power.
2. Feed the exible conduit from the oven through the opening
in the cabinet.
3. Remove junction box cover if it is present.
4. Install a UL-listed or CSA-approved conduit connector
to the junction box.
A. Cable from home power supply B. Black wires C. Red wires D. 4-wire exible cable from oven E. Junction box
F. White wires G. UL-listed wire connectors H. Green (or bare) ground wires I. UL-listed or CSA-approved
conduit connector
1. Connect the 2 black wires (B) together using a UL-listed wire
connector.
2. Connect the 2 red wires (C) together using a UL-listed wire
connector.
3. Untwist white wire from green (or bare) ground wire coming
from the oven.
4. Connect the 2 white wires (F) together using a UL-listed wire
connector.
A. UL-listed or CSA-approved conduit connector
5. Connect the green (or bare) ground wire (H) from the oven
cable to the green (or bare) ground wire (in the junction box) using a UL-listed wire connector.
5. Route the exible conduit from the oven to the junction box
through a UL-listed or CSA-approved conduit connector.
6. Tighten screws on conduit connector.
7. See “Electrical Connection Options Chart” to complete
6. Install junction box cover.
installation for your type of electrical connection.
5