Whirlpool WMH76718AS, WMH75520AS, WMH76718AW, GMH3204XV, GMH5205XV Dimensions

...
PRODUCT MODEL NUMBERS PRODUCT DIMENSIONS
VENTING REQUIREMENTS
Electrical: A 120-Volt, 60-Hz, AC-only, 15- or 20-amp fused electrical
supply with a fuse or circuit breaker. A time-delay fuse or time-delay circuit breaker is recommended. It is recommended that a separate circuit serving only this microwave oven be provided.
Microwave Hood Combination
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
Ref. W10247296B
8/15/12
CABINET OPENING DIMENSIONS
A 3¹⁄₄" x 10" (8.3 x 25.4 cm) rectangular or 6" (15.2 cm) round vent should be used. The total length of the vent system including straight vent, elbow(s), transitions and wall
or roof caps must not exceed the equivalent of 140 ft (42.7 m) for either type of vent. For best performance, use no more than three 90° elbows. To calculate the length of the system you need, add the equivalent length for each vent
piece used in the system. See the following examples:
E
D
The grounded 3-prong outlet must be inside the upper cabinet.
A. 2" x 4" wall stud B. Grounded 3-prong outlet
*30" (76.2 cm) is typical for 66" (167.6 cm) installation height.
Exact dimensions may vary depending on type of range/cooktop below.
GMH3204XV GMH5205XV GMH6185XV WMH1162XV WMH1163XV WMH1164XW
WMH2175XV WMH2205XV WMH3205XV WMH31017A WMH32517A WMH53520A
WMH32L19A WMH73L20A WMH75520A WMH76718A
"
17
(43.8 cm)
15
(40.0 cm)
"
29
" (76.0 cm)
"
16
(41.3 cm)
A B C
D E F G
A. Rectangular to round transition piece: 3
(8.3 x 25.4 cm to 15.2 cm = 1.5 m) B. Roof cap: 3 C. 90° elbow: 3 D. 90° elbow: 6" = 10 ft (15.2 cm = 3 m) E. Wall cap: 3 F. 4 5° elbow: 6" = 5 ft (15.2 cm = 1.5 m) G. 90° flat elbow: 3
" x 10" = 24 ft (8.3 x 25.4 cm = 7.3 m)
" x 10" = 25 ft (8.3 x 25.4 cm = 7.6 m)
" x 10" = 40 ft (8.3 x 25.4 cm = 12.2 m)
" x 10" = 10 ft (8.3 x 25.4 cm = 3 m)
" x 10" to 6" = 5 ft
6" (15.2 cm) vent system = 73 ft (22.2 m) total
A B
6 ft (1.8 m)
A B
30"
(76.2 cm)
min.
30"
(76.2 cm)
typical*
66" (167.6 cm) min.
12" (30.5 cm) min. 14" (35.6 cm) max. upper cabinet and
side cabinet depth
2 ft
(0.6 m)
C
straight = 8 ft (2.4 m)
D
3 " x 10" (8.3 x 25.4 cm) vent system = 73 ft (22.2 m) total
A B
6 ft (1.8 m)
2 ft
(0.6 m)
C
A. One 3 " x 10" (8.3 x 25.4 cm) 90° elbow = 25 ft (7.6 m) B. 1 wall cap = 40 ft (12.2 m) C. 2 ft (0.6 m) + 6 ft (1.8 m) straight = 8 ft (2.4 m)
Rectangular to Round Transition for Roof Venting
NOTE: The minimum 3" (7.6 cm) clearance must exist between
the top of the microwave oven and the rectangular to round transition piece so that the damper can open freely and fully.
A
B
C
3" (7.6 cm)
A. Roof cap B. 6" (15.2 cm) min. diameter round vent C. Elbow (for wall venting only) D. Wall cap E. 3
F
" x 10" to 6" (8.3 x 25.4 cm to 15.2 cm)
rectangular to round transition piece
F. Vent extension piece, at least 3" (7.6 cm) high