Whirlpool WHD3090GW User Manual

Heat Pump Dryer
PRODUCT MODEL NUMBERS
WHD3090G WHD5090G
DRYER DIMENSIONS
Front view:
1
331⁄2" Min.
33
(851 mm)
(851 mm)
3
/4" Max.
33
341⁄2" Max.
(857 mm)
(876 mm)
Side view:
1
435⁄16"
41
/2"
(1100 mm)
(1054 mm)
24"
24"
(610 mm)
(610 mm)
(654 mm)
(610 mm)
26"
24"
Back view:
hose from pump
White
to water tank
NOTES:
Allow clearance
behind dryer for proper drain hose
Grey water drain
routing and cooling fan ventilation. Push dryer back as far as possible and make
Cooling
fan
sure drain hose is not crushed or kinked.
Water can be
drained into an alternate location. Remove the top end of the white
1
7
/4 "
(184 mm)
4"
(102 mm)
Power cord/
cable
3
/4"
(18 mm)
hose from the water tank and install, for example, in a floor standpipe (see “Drain System”).
IMPORTANT: Do not block cooling fan as your dryer may not operate properly.
3
/4"
(18 mm)
W10858718B
11/2016
Installation spacing for recessed area or closet installation
All dimensions show recommended and minimum spacing allowed.
Additional spacing should be considered for ease of
installation and servicing.
Additional clearances might be required for wall, door,
floor, moldings, and drain system.
Additional spacing should be considered on all sides
of the dryer to reduce noise transfer.
For closet installation with a door, minimum ventilation
openings in the top and bottom of the door are required. Louvered doors with equivalent ventilation openings are acceptable.
Companion appliance spacing should also be considered.
Custom under-counter installation:
0" Min. (0 mm)
341⁄2" Min.
(876 mm)
1" Min.
(25 mm)
1" Min.
(25 mm)
Recommended installation clearances (dryer only):
3"
(76 mm)
(76 mm)
1"
3"
48 in.2 min.
(310 cm
24 in.2 min.
(155 cm2)
*NOTE: 0"–5" (0 mm–127 mm) spacing is allowed behind dryer, providing drain hose is not kinked or pinched.
0" - 5"*
(0 mm - 127 mm)
18" min.
(457 mm)
1"
(25 mm)
(25 mm)
Mobile home – Additional installation requirements:
This dryer is suitable for mobile home installations. The installation must conform to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile home construction and Safety, Title 24, HUD Part 280) or Standard CAN/CSA-Z240 MH.
2
)
DRAIN SYSTEM
Drain system can be installed by routing the white hose to a floor drain, wall standpipe, floor standpipe, or laundry tub instead of to the water tank. Select the method you need.
IMPORTANT: To avoid siphoning, only 4.5" (114 mm) of drain hose should be inside standpipe; do not force excess hose into standpipe. Always secure drain hose with a cable tie (not supplied).
Floor standpipe drain system
max. 48"
4.5"
4.5"
(114 mm)
(114 mm)
Minimum diameter for a standpipe drain: 2" (51 mm). Top of standpipe must be at least 30" (762 mm) high; install no higher than 36" (910 mm) from bottom of dryer.
max. 36"
(1219 mm)
(910 mm)
min. 30"
min. 30"
(762 mm)
(762 mm)
ELECTRICAL REQUIREMENTS
To supply the required 3- or 4-wire, single-phase, 120-/240-volt, 60 Hz., AC-only electrical supply (or 3- or 4-wire, 120-/208-volt electrical supply, if specied on the serial/rating plate) on a separate 30-amp circuit, fused on both sides of the line. A time-delay fuse or circuit breaker is recommended. Connect to an individual branch circuit. Do not have a fuse in the neutral or grounding circuit. Do not use an extension cord.
Because Whirlpool Corporation policy includes a continuous commitment to improve Dimensions are for planning purposes only. For complete details, see Installation our products, we reserve the right to change materials and specications without notice. Instructions packed with product. Specications subject to change without notice.