Whirlpool WHCF-DWHV Owner's Manual

04/04 INSTR7022 1203 Whirlpool Water Products 8562176 Meriden CT, 06450
Model
WHCF-DWHV
Filter Replacement:
The contaminants or other substances removed or reduced by this water filter are not necessarily in all users’ water.
Filter life depends on local water conditions and the volume of water used.We recommend you change the WHCF-GD05 fil­ter every 6 months.However, it can be replaced earlier if there is a drop in water pressure.
Do not use with water that is microbiologically unsafe or of unknown quali­ty without adequate disinfection before or after the system. Systems certified for Cyst reduction may be used on disinfected water that may contain filterable cysts.EPA Establishment #070595-CT-001
Filter Cartridge Replacement Instructions:
NOTE: Before changing cartridge, turn off or bypass incom-
ing water supply. Place a bucket under filter to catch the small amount of water that will run out after housing removal.
1. Shut off water by turning valve on filter head to the “OFF” or “BYPASS” position.
2. Unscrew housing and remove old cartridge.Wash housing thoroughly with mild soap and water.
3. Insert new cartridge and re-install housing. Be sure cartridge is seated in the housing before tightening onto head.
4. Use filter wrench to fully seat the cartridge. Tighten to make a water tight seal.
5. Turn on water by turning valve on filter head to the “FILTER” position. If any leaks appear, tighten housing as needed.
6. Flush system for five (5) minutes.
Troubleshooting Guide
Water Leaks at Fittings: Tighten slightly more until leak stops.
Water leaks at connections: Refer to section “Using Push-In Fittings.” Push pipe in as far as it will go.If leaking continues, shut off water at the incoming valve and remove water line by pushing in on the connector collar while pulling the pipe away.Inspect pipe for cracks and scratches. If pipe is cracked or scratched, simply cut that portion away and reinsert pipe into fitting.
Accessories:
To order accessories, ask for the appropriate part number list­ed below or contact the Help Line listed below:
WHCF-GRND Grounding kit for metallic piping WHCF-B6 Bracket for pipe support
Help Line 1-866-245-9474
Monday Through Friday
8:00 a.m. to 9:00 p.m. EST
or write us at
Whirlpool Water Products
PO Box 765
Meriden, CT 06450
WHOLE HOUSE
PREFILTRATION
Standard System with Shut-Off Valve
Installation, Use & Care Guide
8562176/INSTR7022 1203
® Registered trademark/TM Trademark of Whirlpool, USA,
used under license.
© 2004 Whirlpool Corporation. All r ights reser ved.
TEFLON is a registered trademark of E.I. Dupont
® Marca registrada/TM Marca de comercio de Whirlpool, USA,
usado bajo licencia. Todos los derechos reservados. TEFLON es una marca registrada de E.I. Dupont
1 Y ear Limited Warranty
CUNO Incorporated warrants the original purchaser-consumer of its Product that is free of defects in materials and workmanship.Any defect, malfunction, or other failure of the Product to conform to this warranty will be remedied by Warrantor in the manner provided below.
This Warranty, together with any warranties implied by law, shall be limited to a duration of one (1) year from the original date of purchase by the consumer.
This Warranty does not apply to defects that result from abuse, misuse, alter­ation or damage not caused by CUNO Incor porated.
THIS WARRANTY DOES NOT COVER, AND IS INTENDED TO EXCLUDE ANY LIABILITY ON THE PART OF WARRANTOR, WHETHER UNDER THIS WAR­RANTY OR UNDER ANY WARRANTY IMPLIED BY LAW, FOR ANY INDIRECT OR CONSEQUENTIAL DAMAGES FOR BREACH HEREOF OR THEREOF.
Note: Some states prohibit limitations on the duration of implied warranties and on the exclusion of indirect or consequential damages; and so the limitation on implied warranties and on incidental and consequential damages may not be applicable to you.
RESPONSIBILITY OF WARRANTOR
CUNO Incorporated’s responsibility under this warranty shall be to repair at its expense, at no charge to the original purchaser-consumer any product that is actually defective, malfunctioning or otherwise in violation of this warranty.If CUNO Incorporated for any reason cannot repair a Product covered hereby within two (2) weeks after receipt of the original purchaser-consumer’s notifica­tion of a Warranty claim and the Product, then CUNOIncorporated’s responsi­bility shall be, at its option, either to replace the defective Product with a compa­rable new unit at no charge to the consumer or to refund the full purchase price. CUNO Incorporated’s obligations of repair, replacement, or refund are condi­tioned upon the return of the defective product to CUNO Incor porated.
If any Product hereby is actually defective within the terms of this Warranty, then CUNO Incorporated will bear all the reasonable and proper shipping and mail­ing charges actually incurred in the consumer’s return of the Product set forth herein. If the Product proves not to be defective within the terms of this Warranty, then all costs and expenses in connection with the processing of the consumer’s claim hereunder shall be borne by the consumer.
RESPONSIBILITY OF THE CONSUMER The original purchaser-consumer’s sole responsibility in the instance of a war­ranty claim shall be to notify CUNO Incorporated of the defect, malfunction or other manner in which the terms of this Warranty are violated.You may secure performance or obligations hereunder by (in writing):
1. Identifying the Product involved (by model or serial number or other sufficient description that will allow Warrantor to determine which product is defective).
2. Specifying where, when and from whom the Product was purchased.
3. Describing the nature of the defect, malfunction or other violation of this Warranty.
4. Return the Product, with the above information to:
CUNO Incorporated, 400 Research Parkway,Meriden, CT 06450, U.S.A.
THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS, AND YOU MAY
ALSO HAVE OTHER RIGHTS, WHICH VARY FROM STATE TO STATE.
Ground Clamp Ground Clamp
Ground Wire
Ground Clamp Ground Clamp
Ground Wire
Parts and Material Included:
1. Filter Head
2. Clear Housing
3. Sediment Filter
4. Housing Wrench
5. Two 3/4” MNPT* x 3/4” Fitting for Copper Pipe
Tools and Parts Needed:
Gather the required tools before starting installation. Read and follow the instructions provided with any tools listed here.
• Teflon®Tape • Adjustable Wrench
Installation Requirements:
• Properly tighten all fittings to ensure a leak-free assembly.
• Filter housing is intended for use on cold water line.
• Install in a location that is not susceptible to freezing temperatures as damage to the housing could occur.
• Install away from direct sunlight as prolonged exposure to light can weaken plastic components.
• Allow a minimum of 2” (5.1 cm) clear space below unit to facili­tate filter change.
• Some local codes may require the use of a licensed plumber or certified installer when disrupting a potable water line. Determine and follow any and all local codes and requirements.
• Pipe and filter need to be properly supported with either pipe hangers or optional Whirlpool bracket (WHCF-B6).
• For metal water piping systems a grounding connection is required (Whirlpool Grounding Kit WHCF-GRND).
Installation Instructions:
For Use With Cold Water Only
1. Shut off main water supply.Drain water from water lines.
2. Remove clear housing from filter head and set aside.
3.Wrap Teflon®tape (2 1/2 wraps) around the 3/4” MNPT x 3/4” fitting for copper pipe in a clockwise direction (see Figure 1) and firmly assemble into filter head. Do not use pipe sealant (dope), as solvents in some types of pipe dope may cause damage to plastic fittings. Do not over­tighten, overtightening can cause damage to filter head.
Figure 1
4. Calculate proper spacing of components (approximately 3/4" of existing pipe inserts into each fitting). (See Figure 2.)
Assure Proper Spacing
Figure 2
5. Install Whirlpool Grounding Kit WHCF-GRND (see Figure 3) in metal water piping systems.
IMPORTANT: Metal water piping systems are required to be connected to the electrical ground.To maintain the ground connection, obtain kit WHCF-GRND by contacting location where filter head was purchased.Ground Kit Installation:
Figure 3
a. Install one ground clamp on the incoming metal water pipe section and one on the outgoing metal water pipe section. Be sure that the filter head, fittings and valves are between the two ground clamps.
b.Connect the ground wire to the two ground clamps, using the wire screw terminal on each grounding clamp.Tighten securely.
6. Cut pipe and clean ends of pipe. Ensure there are no burrs, sharp edges or deep scratches.
7. Referring to “Using Push-In Fittings” section, insert pipe into filter head fitting making sure end of pipe is firmly seat­ed to backstop.Connect pipe from water supply to "IN" port. (See Figure 4.)
Figure 4
8. Repeat Step 7 for the pipe leading from the “OUT” port to the house. It may be necessary to carefully spread pipe apart in order to connect pipes. Keep filter head horizontal.
9. Lubricate housing o-ring with water. Firmly screw housing, with filter inside, to filter head.Tighten with wrench to seal properly.
10.Turn filter head valve to "FILTER" mode (see Figure
5) and slowly turn on main water sup­ply and check for leaks. Run water for 5 minutes with an open faucet to flush out air.
Figure 5
“Using Push-In Fittings”
To Attach Tubing
Push tubing in as far as it will go. Tubing must be inserted past o-ring and hit backstop. Pull tube to ensure it is secured.
To Release Tubing
Push in grey collet to release tubing. With collet held, pull tubing straight out.
Collet
Backstop
* MNPT - Male Nominal Pipe Thread
Loading...
+ 2 hidden pages