INSTALLATION REQUIREMENTS .............................................. 4
VENTING .................................................................................... 10
Venting Requirements ......................................................... 10
Plan Vent System ................................................................. 11
CONNECT VENT ....................................................................... 14
Para una version de estas instrucciones en español, visite www.Whirlpool.com
INSTALLATION NOTES
Date of purchase: _________________________________ Date of installation: ________________________________ Installer: ________________________________________ Model number: ___________________________________ Serial number: ____________________________________
Table des matières
SÉCURITÉ DE LA SÉCHEUSE .................................................. 23
EXIGENCES D’INSTALLATION .................................................25
Outillage et pièces .............................................................25
EXIGENCES D’EMPLACEMENT ............................................... 26
SÉCHEUSE ÉLECTRIQUE RACCORDEMENT À
L’ALIMENTATION ÉLECTRIQUE – CANADA SEULEMENT ....27
RACCORDEMENT D’UNE SÉCHEUSE À GAZ ........................28
INSTALLATION DES PIEDS DE NIVELLEMENT ......................30
RACCORDEMENT AU GAZ ....................................................... 30
ÉVACUATION .............................................................................31
Exigences concernant l’évacuation .................................31
Planication du système d’évacuation ............................32
Installation du système d’évacuation ............................... 34
RACCORDEMENT DU TUYAU D’ALIMENTATION
(MODÈLE À VAPEUR UNIQUEMENT) ......................................34
RACCORDEMENT DU CONDUIT D’ÉVACUATION .................36
RÉGLAGE DE L’APLOMB DE LA SÉCHEUSE..........................36
ACHEVER L’INSTALLATION LISTE DE VÉRIFICATION ...........37
INVERSION DE LA PORTE (FACULTATIF) ................................ 37
NOTES CONCERNANT L’INSTALLATION
Date d’achat: _____________________________________ Date d’installation: _________________________________ Installateur: ______________________________________ Numéro de modéle: ________________________________ Numéro de série: __________________________________
W11101336A
W11101338A-SP
DRYER SAFETY
2
WARNING:
FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury, death, or property
damage.
Do not store or use gasoline or other ammable vapors and liquids in the vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Clear the room, building, or area of all occupants.
Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s
instructions. If you cannot reach your gas supplier, call the re department.
Installation and service must be performed by a qualied installer, service agency, or the gas supplier.
IMPORTANT: The gas installation must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or the Natural Gas and Propane Installation Code, CSA B149.1.
The dryer must be electrically grounded in accordance with local codes, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, Part 1, CSA C22.1.
In the State of Massachusetts, the following installation instructions apply:
Installations and repairs must be performed by a qualified or licensed contractor, plumber, or gas fitter qualified or licensed by
the State of Massachusetts.
Acceptable Shut-off Devices: Gas Cocks and Ball Valves installed for use shall be listed.
A flexible gas connector, when used, must not exceed 4 feet (121.9 cm).
3
INSTALLATION REQUIREMENTS
Tools and Parts
Gather the required tools and parts before starting installation.
Tools needed for all installations:
Flat-blade screwdriver #2 Phillips screwdriver
Parts supplied (all models):
Leveling legs (4)
Parts package is located in dryer drum. Check that all parts are included.
NOTE: Do not use leveling legs supplied with dryer if installing with a pedestal or a stack kit.
Parts needed (steam models):
1/4" and 5/16" nut driver (recommended)
Tape measure Pliers
Utility knife
Caulking gun and compound (new vent installations)
Level
Tin snips (new vent installations)
Adjustable wrench that opens to 1" (25 mm) or hex-head socket wrench
Tools needed for gas installations:
“Y” connector
Rubber washer
Short inlet hose
Inlet hose
Parts needed (not supplied with dryer):
■ Vent clamps
■ Vent elbows and vent work
Additional parts may be required, depending in your installation. Check local codes. Check existing electrical supply and venting. Read “Electrical Requirements” and “Venting Requirements” before purchasing parts.
Optional Equipment: (Not supplied with dryer)
Refer to your Use and Care Guide for information about accessories available for your dryer.
8" or 10" pipe wrench
Pipe-joint compound
resistant to propane gas
4
8" or 10" adjustable wrench (for gas connections)
LOCATION REQUIREMENTS
DRYER DIMENSIONS
Front view:
383/4" Min.
(984 mm)
39" Max.
(990 mm)
27"
(686 mm)
You will need:
■ A location allowing for proper exhaust installation.
See “Venting Requirements.”
■ A separate 15- or 20-amp circuit for a gas dryer or 30-amp
circuit for an electric dryer.
■ If using power supply cord, a grounded electrical outlet
located within 2 ft. (610 mm) of either side of dryer. See “Electrical Requirements.”
■ Floor must support dryer weight of 200 lbs. (90.7 kg).
Also consider weight of companion appliance.
■ Cold water faucets located within 4 ft. (1.2 m) of the water
ll valves, and water pressure of 20–120 psi (138–827 kPa). You may use the water supply for your washer using the necessary parts as noted (which you will need to purchase).
■ Level oor with maximum slope of 1" (25 mm) under entire
dryer. If slope is greater than 1" (25 mm), install Extended Dryer Feet Kit, Part Number 279810. If not level, clothes may not tumble properly and automatic sensor cycles may not operate correctly.
■ For garage installation, place dryer at least 18" (460 mm)
above oor. If using a pedestal, you will need 18" (460 mm) to bottom of dryer.
■ The dryer must not be installed or stored in an area where
it will be exposed to water and/or weather.
IMPORTANT: Do not operate, install, or store dryer where it will be exposed to water, weather, or at temperatures below 40°F (4°C). Lower temperatures may cause dryer not to shut off at end of automatic sensor cycles, resulting in longer drying times.
Side view:
Back view:
*Approx. measurement
61/4"
(159 mm)
7
29
/8"*
1
/8"*
6
(759 mm)
1
/2"*
3
(89 mm)
53/4"*
(146 mm)
3
/4"*
(18 mm)
Vent
Gas
Water inlet
(Steam Models Only)
3
14
/8"
(365 mm)
253/4"
(654 mm)
(156 mm)
*Approx. measurement
NOTE: Most installations require a minimum of 5" (127 mm) clearance behind dryer for exhaust vent with elbow. See “Venting Requirements.”
5
Installation Clearances
For each arrangement, consider allowing more space for ease of installation and servicing, as well as spacing for companion appliances and clearances for walls, doors, and oor moldings. Space must be large enough to allow door to fully open. Add spacing on all sides of dryer to reduce noise transfer. If a closet door or louvered door is installed, top and bottom air openings in door are required.
Check code requirements. Some codes limit, or do not permit, installation of the dryer in garages, closets, mobile homes, or sleeping quarters. Contact your local building inspector.
NOTE: No other fuel-burning appliance can be installed in the same closet as a dryer.
Mobile home installations require:
■ Metal exhaust system hardware, available for purchase from
your dealer. For further information, see the “Assistance or Service” section in your Use and Care Guide.
■ Special provisions must be made in mobile homes to introduce
outside air into dryer. Openings (such as a nearby window) should be at least twice as large as dryer exhaust opening.
For mobile home installation of gas dryers:
■ Mobile Home Installation Hold-Down Kit Part Number
346764 is available to order. For further information, see the “Assistance or Service” section in your Use and Care Guide.
Installation spacing for recessed area or closet installation
All dimensions show recommended and minimum spacing allowed.
■ Additional spacing should be considered for ease of
installation and servicing.
■ Additional clearances might be required for wall, door, oor
moldings, dryer venting, and gas line.
■ Additional spacing should be considered on all sides
of the dryer to reduce noise transfer.
■ For closet installation, with a door, minimum ventilation
openings in the top and bottom of the door are required. Louvered doors with equivalent ventilation openings are acceptable.
■ Companion appliance spacing should also be considered.
Recommended installation clearances (dryer only):
3"
18" min.
(457 mm)
*
5"
(127 mm)
1"
(25 mm)
*0" (0 mm) spacing is allowed.
*
1"
(25 mm)
(76 mm)
3"
(76 mm)
48 in.2 min.
(310 cm
24 in.2 min.
(155 cm2)
ELECTRIC DRYER POWER HOOKUP – CANADA ONLY
ELECTRICAL REQUIREMENTS
It is your responsibility:
■ To contact a qualied electrical installer.
■ To be sure that the electrical connection is adequate and in
conformance with Canadian Electrical Code, C22.1 – latest
2
)
edition and all local codes. A copy of above codes standard may be obtained from: Canadian Standards Association, 178 Rexdale Blvd., Toronto, ON M9W 1R3 CANADA.
■ To supply the required 4-wire, single-phase, 120-/240-volt,
60 Hz, AC-only electrical supply on a separate 30-amp circuit, fused on both sides of the line. A time-delay fuse or circuit breaker is recommended. Connect to an individual branch circuit.
■ This dryer is equipped with a UL-listed
or CSA International Certied Power Cord intended to be plugged into a standard 14-30R wall receptacle. The cord is 5 ft. (1.52 m) long. Be sure wall receptacle is within reach of dryer’s nal location.
4-wire receptacle
(14-30R)
Mobile home – Additional installation requirements:
This dryer is suitable for mobile home installations. The installation must conform to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile home construction and Safety, Title 24, HUD Part 280) or Standard CAN/CSA-Z240 MH.
6
If using a replacement power supply cord, it is recommended that you use Power Supply Cord Replacement Part Number 8529008.
For further information, please reference service numbers located in “Assistance or Service” section of your Use and Care Guide.
GROUNDING INSTRUCTIONS
For a grounded, cord-connected dryer:
This dryer must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current. This dryer is equipped with a cord having an equipment­grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.
WARNING: Improper connection of the equipment-
grounding conductor can result in a risk of electric shock. Check with a qualied electrician or service representative or personnel if you are in doubt as to whether the dryer is properly grounded. Do not modify the plug provided with the dryer: if it will not t the outlet, have a proper outlet installed by a qualied electrician.
GROUNDING INSTRUCTIONS
For a grounded, cord-connected dryer:
This dryer must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current. This dryer is equipped with a cord having an equipment­grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.
WARNING: Improper connection of the equipment-
grounding conductor can result in a risk of electric shock. Check with a qualied electrician or service representative or personnel if you are in doubt as to whether the dryer is properly grounded. Do not modify the plug provided with the dryer: if it will not t the outlet, have a proper outlet installed by a qualied electrician.
SAVE THESE INSTRUCTIONS
GAS SUPPLY REQUIREMENTS
SAVE THESE INSTRUCTIONS
GAS DRYER POWER HOOKUP
ELECTRICAL REQUIREMENTS
■ 120-volt, 60 Hz, AC-only, 15- or 20- amp fused electrical
supply is required. A time-delay fuse or circuit breaker is recommended. It is also recommended that a separate circuit serving only this dryer be provided.
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to propane, have a qualified person make sure gas pressure does not exceed 13" (330 mm) water column.
Examples of a qualified person include:
licensed heating personnel, authorized gas company personnel, and authorized service personnel.
Failure to do so can result in death, explosion, or fire.
GAS TYPE
Natural Gas:
This dryer is equipped for use with natural gas. It is design­certied by UL for use with propane gas with appropriate conversion.
■ Your dryer must have the correct burner for the type of gas in
your home. Burner information is located on the rating plate in the door well of your dryer. If this information does not agree with the type of gas available, contact your dealer or call the phone numbers referenced in the “Assistance or Service” section of your Use and Care Guide.
Propane Gas Conversion:
IMPORTANT: Conversion must be made by a qualied
technician. No attempt shall be made to convert the appliance from the gas
specied on the model/serial rating plate for use with a different gas without consulting your gas company.
7