Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol.
Thissymbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.”
These words mean:
You can be killed or seriously injured if you don't immediately
DANGER
WARNING
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can
happen if the instructions are not followed.
follow instructions.
can be killed or seriously injured if you don't
You
instructions.
follow
3
IMPORTANT: The gas installation must conform with local codes, or in the absence of local codes, with the National Fuel Gas
Code, ANSI Z223.1/NFPA 54 or the Canadian Natural Gas and Propane Installation Code, CSA B149.1.
The dryer must be electrically grounded in accordance with local codes, or in the absence of local codes, with the National
Electrical Code, ANSI/NFPA 70 or Canadian Electrical Code, CSA C22.1.
WARNING: For your safety, the information in this manual must be followed to minimize
the risk of re or explosion, or to prevent property damage, personal injury, or death.
– Do not store or use gasoline or other ammable vapors and liquids in the vicinity of this
or any other appliance.
– WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
•
Do not touch any electrical switch; do not use any phone in your building.
•
Clear the room, building, or area of all occupants.
•
Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's
•
instructions.
If you cannot reach your gas supplier, call the re department.
•
– Installation and service must be performedby a qualied installer, service agency, or
the gas supplier.
4
WARNING: Gas leaks cannot always be detected by smell.
Gas suppliers recommend that you use a gas detector approved by UL or CSA.
For more information, contact your gas supplier.
If a gas leak is detected, follow the “What to do if you smell gas” instructions.
In the State of Massachusetts, the following installation instructions apply:
■
Installations and repairs must be performed by a qualied or licensed contractor, plumber, or gastter qualied or licensed by
the State of Massachusetts.
■
If using a ball valve, it shall be a T-handle type.
■
A exible gas connector, when used, must not exceed 3 feet.
INSTALLATION INSTRUCTIONS
Parts needed:
Tools and Parts
Gather the required tools and parts before starting installation. Read
and follow the instructions provided with any tools listed here.
■ 8" or 10" pipe wrench
■ 8" or 10" adjustable wrench
(for gas connections)
■ Flat-blade screwdriver
■ Adjustable wrench that
opens to 1" (25 mm) or hexhead socket wrench (for
adjusting dryer feet)
■ Level
■ ¼" nut driver or socket
wrench
■ Knife
■ Vent clamps
■ Pipe-joint compound
resistant to LP gas
■ Caulking gun and compound
(for installing new exhaust
vent)
■ Pliers
Check local codes and consult gas supplier. Check existing gas
supply, electrical supply, and venting, and read “Electrical
Requirements,” “Gas Supply Requirements,” and “Venting
Requirements” before purchasing parts.
Mobile home installations require special parts (listed following) that
may be ordered by calling the dealer from whom you purchased
your dryer. For information on ordering, please refer to the
“Assistance or Service” section. You may also contact the dealer
from whom you purchased your dryer.
■ Mobile home installation kit. Ask for Part Number 346764.
■ Metal exhaust system hardware.
Location Requirements
Parts supplied:
Remove parts package from dryer drum. Check that all parts were
included.
A
B
C
A. Leveling legs (4)
B. “Y” connector
C. Short inlet hose
D. Long inlet hose
E. Rubber washer
D
E
You will need
■ A location that allows for proper exhaust installation. See
“Venting Requirements.”
■ A separate 30-amp circuit.
5
■ A grounded electrical outlet located within 2 ft (610 mm) of either
side of the dryer. See “Electrical Requirements.”
■ A sturdy floor to support the total weight (dryer and load) of
200 lbs (90.7 kg). The combined weight of a companion
applia
nce should also be considered.
■ Cold water faucets located within 4 ft (1.2 m) of the water fill
valves, and water pressure of 20-100 psi (138-690 kPa). You
may use the water supply for your washer using the “Y”
connector and short hose (if needed) which are provided.
■ 20-100 psi (138-690 kPa) for best performance.
■ A level floor with a maximum slope of 1" (25 mm) under entire
dryer.
Do not operate your dryer at temperatures below 45ºF (7ºC). At
lower temperatures, the dryer might not shut off at the end of an
automatic cycle. Drying times can be extended.
The dryer must not be installed or st
ored in an area where it will be
exposed to water and/or weather.
Check code requirements. Some codes limit, or
do not permit,
installation of the dryer in garages, closets, mobile homes, or
sleeping quarters. Contact your local building inspector.
No other fuel-burning appliance can be installed in the same
NOTE:
closet as a dryer.
Installation Clearances
The location must be large enough to allow the dryer door to open
fully.
Dryer Dimensions
1
43
/2"
(1105 mm)
■ Additional spacing is required if you exhaust out the rear of the
dryer to either the right or left side.
14" máx.*
18"*
(457 mm)
1"
(25 mm)
29"
(737 mm)
A
(356 mm)
1"
(25 mm)
A. Recessed area
B. Side view - closet or confined area
C. Closet door with vents
1
/4"
29
(743 mm)
B
48 in.2*
(310 cm2)
2
24 in.
*
(155 cm2)
5"
(127 mm)
3"*
(76 mm)
3"*
(76 mm)
C
*Required spacing
Mobile home - Additional installation requirements
This dryer is suitable for mobile home installations. The installation
must conform to the Manufactured Home Construction and
Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal
Standard for Mobile Home Construction and Safety, Title 24, HUD
Part 280) or Standard CAN/CSA-Z240 MH.
Mobile home installations require:
■ Metal exhaust system hardware, which is available for
purchase from your dealer.
■ Mobile home Installation Kit Part Number 346764. See “Tools
and Parts” section for information on ordering.
■ Special provisions must be made in mobile homes to
introduce outside air into the dryer. The opening (such as a
nearby window) should be at least twice as large as the dryer
exhaust opening.
1
/4"
1
29
/4"
(743 mm)
29"
(737 mm)
22
(565 mm)
*Most installations require a minimum 5" (127 mm) clearance
behind the dryer for the exhaust vent with elbow. See “Venting
Requirements.”
Installation spacing for recessed area or closet installation
The following spacing dimensions are recommended for this dryer.
This dryer has been tested for spacing of 0" (0 mm) clearance on the
sides an
following reasons:
■ Additional spacing should be considered for ease of installation
■ Additional clearances might be required for wall, door, and floor
■ Additional spacing should be considered on all sides of the dryer
■ For closet installation, with a door, minimum ventilation openings
■ Companion appliance spacing should also be considered.
d rear. Recommended spacing should be considered for the
and servicing.
moldings.
to reduce noise transfer.
in the top and bottom of the door are required. Louvered doors
with equivalent ventilation openings are acceptable.
Electrical Requirements
WARNING
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
re, or electrical shock.
■ 120 Volt, 60 Hz., AC only, 15- or 20-amp fused electrical supply
is required. A time-delay fuse or circuit breaker is recommended.
6
It is also recommended that a separate circuit serving only this
dryer be provided.
GROUNDING INSTRUCTIONS
■
For a grounded, cord-connected dryer:
This dryer must be grounded. In the event of malfunction or
breakdown, grounding will reduce the risk of electric shock
by providing a path of least resistance for electric current.
This dryer is equipped with a cord having an equipmentgrounding conductor and a grounding plug. The plug must
be plugged into an appropriate outlet that is properly
installed and grounded in accordance with all local codes
and ordinances.
WARNING: Improper connection of the equipment-
grounding conductor can result in a risk of electric shock.
Check with a qualied electrician or service representative
or personnel if you are in doubt as to whether the dryer is
properly grounded. Do not modify the plug provided with
the dryer: if it will not t the outlet, have a proper outlet
installed by a qualied electrician.
SAVE THESE INSTRUCTIONS
Gas Supply Requirements
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualied person make sure
gas pressure does not exceed 13" (330 mm) water
column.
Examples of a qualied person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or re.
Gas Type
LP gas conversion:
Conversion must be made by a qualified technician.
No attempt shall be made to convert
the appliance from the gas
specified on the model/serial rating plate for use with a different gas
without consulting your gas company. For information on ordering
an LP conversion kit, please refer to the “Assistance or Service”
section. Ask for Part Number 49572.
Gas Supply Line:
■ Must include
test gauge connection, immediately upstream of the gas
connection to the dryer (see illustration).
1
■
/2" IPS pipe is recommended.
3
■
/8" approved aluminum or copper tubing is acceptable for
lengths under 20 ft (6.1 m) if local codes and gas supplier
permit.
■ If you are using Natural gas, do not use copper tubing.
3
■
/8" flare x 3/8" NPT adapter fitting between dryer pipe and 3/8"
approved tubing.
■ Lengths over 20 ft (6.1 m) should use larger tubing and a
different size adapter fitting.
■ If your dryer has been converted to use LP gas,
compatible copper tubing can be used. If the total length of the
supply line is more than 20 ft (6.1 m), use larger pipe.
NOTE:
must be used. Do not use TEFLON
■ Must include a shutoff valve:
In the U.S.A.:
An individual manual shutoff valve must be installed within
six (6) feet (1.8 m) of the dryer in accordance with the National
Fuel Gas
In Canada:
An individual manual
accordance with the B149.1, Natural Gas and Propane
Installation Code. It is recommended that an individual
manual shutoff valve be installed within six (6) feet (1.8 m) of
the d
ryer.
The location should be easy to reach for opening and closing.
1
/8" NPT minimum plugged tapping accessible for
3
/8" LP
Pipe-joint compounds that resist the action of LP gas
®†
tape.
Code, ANSI Z223.1.
shutoff valve must be installed in
A
C
E
D
B
A.3/8" flexible gas connector
3
B.
/8" pipe to flare adapter fitting
1
/8" NPT minimum plugged tapping
C.
1
/2" NPT gas supply line
D.
E. Gas shutoff valve
Natural Gas:
This dryer is equipped for use with Natu
ral gas. It is design-certified
by CSA International for LP (propane or butane) gases with
appropriate conversion.
■ Your dryer must have the correct burner for the type of gas in
your home. Burner information is located on the rating plate in
the door well of your dryer. If this information does not agree
with the type of gas available, contact your dealer or call the
phone numbers referenced on the front page of this manual.
Gas supply connection requirements
■ Use an elbow and a
between the flexible gas connector and the dryer gas pipe, as
needed to avoid kinking.
■ Use only pipe-joint compound. Do not use TEFLON
■ This dryer must be connected to the gas supply line with a
listed flexible gas connector that complies with the standard
for connectors for gas appliances, ANSI Z21.24 or CSA 6.10.
†
®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.
3
/8" flare x 3/8" NPT adapter fitting
®†
tape.
7
Burner Input Requirements:
If this is a new vent system
Elevations above 10,000 ft (3,048 m):
■ When installed above 10,000 ft (3,048 m) a 4% reduction of
the burner Btu rating shown on the model/serial number plate
is required for each 1,000 ft (305 m) increase in elevation.
Gas Supply Pressure Testing
■ The dryer must be disconnected from the gas supply piping
system during pressure testing at pressures greater than ½ psi.
Dryer Gas Pipe
■ The gas pipe that comes out through the rear of your dryer has a
1
/8" male pipe thread.
2"
(51 mm)
3
A
A.3/8" NPT dryer pipe
/4"
(19 mm)
Venting Requirements
WARNING
Fire Hazard
Use a heavy metal vent.
Do not use a plastic vent.
Do not use a metal foil vent.
Failure to follow these instructions can result in death
or re.
Vent material
■ Use a heavy metal vent. Do not use plastic or metal foil vent.
■ 4" (102 mm) heavy metal exhaust vent and clamps must be
used. DURASAFE™ venting products are recommended.
4" (102 mm) heavy metal exhaust vent
DURASAFE™ vent products can be purchased from your dealer
or by calling Whirlpool Parts and Accessories. For more
information, see the “Assistance or Service” section.
Rigid metal vent
■ For best drying performance, rigid metal vents are
recommended.
■ Rigid metal vent is recommended to avoid crushing and kinking.
Flexible metal
■ Flexible metal vents are acceptable only if accessible for
cleaning.
■ Flexible metal vent must be fully extended and supported when
the dryer is in its final location.
■ Remove excess flexible metal vent to avoid sagging and kinking
that may result in reduced airflow and poor performance.
■ Do not install flexible metal vent in enclosed walls, ceilings, or
floors.
■ The total length of flexible metal duct shall not exceed 7
(2.4 m).
Elbows
45° elbows provide better airflow than 90° elbows.
vent
3
/4 ft
WARNING:To reduce the risk of fire, this dryer MUST BE
EXHAUSTED OUTDOORS.
IMPORTANT: Obse
The dryer exhaust must not be connected into any gas vent,
imney, wall, ceiling, attic, crawlspace, or a concealed space of a
ch
building.
If using an existing vent system
■ Clean lint from the entire length of the system and make sure
exhaust hood is not plugged with lint.
■ Replace any plastic or metal foil vent with rigid heavy metal or
flexible metal vent.
■ Review Vent system chart. Modify existing vent system if
necessary to achieve the best drying performance.
8
rve all governing codes and ordinances.
GoodBetter
Clamps
■ Use clamps to seal all joints.
■ Exhaust vent must not be connected or secured with screws or
other fastening devices that extend into the interior of the duct
and catch lint. Do not use duct tape.
Clamp
Exhaust
A
Recommended hood styles are shown here.
B
A
4"
(102 mm)
4"
(102 mm)
A. Louvered hood style
B. Box hood style
The angled hood style (shown here) is acceptable.
4"
(102 mm)
■ An exhaust hood should cap the vent to keep rodents and
C
2½"
(64 mm)
insects from entering the home.
■ Exhaust hood must be at least 12" (305 mm) from the ground or
any object that may be in the path of the exhaust (such as
flowers, rocks, or bushes, snow line, etc.).
■ Do not use an exhaust hood with a magnetic latch.
Improper venting can cause moisture and lint to collect
indoors, which may result in:
Moisture damage to woodwork, furniture, paint, wallpaper,
carpets, etc.
Housecleaning problems and health problems.
Plan Vent System
Choose your exhaust installation type
Recommended exhaust installations
Typical installations vent the dryer from the rear of the dryer.
B
C
D
E
F
G
Standard exhaust installation with rigid metal or flexible
metal vent
Alternate installations for close clearances
Venting systems come in many varieties. Select the type best for
your installation. Two close-clearance installations are shown. Refer
to the manufacturer’s instructions.
A
A. Over-the-top installation (also available with one offset elbow)
B. Periscope installation
C. Rear exhaust installation
to left or right side
NOTE: The following kits for close clearance alternate installations
are available for purchase. Please see the “Assistance or Service”
section to order.
■ Over-the-Top Installation:
Part Number 4396028
■ Periscope Installation (For use with dryer vent to wall vent
mismatch):
Part Number 4396037 - 0" (0 mm) to 18" (457 mm) mismatch
Part Number 4396011 - 18" (457 mm) to 29" (737 mm)
mismatch
Part Number 4396014 - 29" (737 mm) to 50" (127 mm)
mismatch
■ Rear exhaust installation to left or right side:
Part Number 49611
■ Rear Exhaust installation to left side
Part Numbers 8544761 and 8212504
Special provisions for mobil
e home installations
The exhaust vent must be securely fastened to a noncombustible
portion of the m
obile home structure and must not terminate
beneath the mobile home. Terminate the exhaust vent outside.
B
C
A. Dryer
B. Elbow
C. Wall
D. Exhaust hood
E. Clamps
F. Rigid metal or flexible metal vent
G. Vent length necessar
H. Exhaust outlet
B
H
y to connect elbows
9
Determine vent path
■ Select the route that will provide the straightest and most direct
path outdoors.
■ Plan the installation to use the fewest number of elbows and
turns.
■ When using elbows or making turns, allow as much room as
possible.
■ Bend vent gradually to avoid kinking.
■ Use the fewest 90° turns possible.
Determine vent length and elbows needed for best
drying performance
■ Use the following Vent system chart to determine type of vent
material and hood combinations acceptable to use.
NOTE: D
Vent system chart. Exhaust systems longer than those specified
will:
■ Shorten the life of the dryer.
■ Reduce performance, resulting in longer drying times and
The Vent system chart provides venting r
to achieve the best drying performance.
o not use vent runs longer than those specified in the
increased energy usage.
equirements that will help
Install Leveling Legs
WARNING
Excessive Weight Hazard
Use two or more people to move and install dryer.
Failure to do so can result in back or other injury.
1. To avoid damaging the floor, use a large flat piece of cardboard
from the dryer carton. Place cardboard under the entire back
edge of the dryer.
2. F
irmly grasp the body of the dryer (not the top or console panel).
Gently lay the dryer on the cardboard. See illustration.
3. Examine the leveling legs. Find the diamond marking.
Vent system chart
NOTE: Performance of rear exhaust to either side of the dryer is
equivalent to adding one elbow. To determine maximum exhaust
length, add one elbow to the chart.
Number of
90º turns
or elbows
0Rigid meta
1Rigid meta
2Rigid meta
3Rigid meta
4Rigid meta
Type of
ven
Box or
t
l64 ft (20 m)58 ft (17.7 m)
l54 ft (16.5 m) 48 ft (14.6 m)
l44 ft (13.4 m)38 ft (11.6 m)
l35 ft (10.7 m)29 ft (8.8 m)
l27 ft (8.2 m)21 ft (6.4 m)
Louvered
hoods
Angled
hoods
Install Vent System
1. Install exhaust hood. Use caulking compound to seal exterior wall
opening around exhaust hood.
onnect vent to exhaust hood. Vent must fit inside exhaust hood.
2. C
Secure vent to exhaust hood with 4" (102 mm) clamp.
3. Run
vent to dryer location. Use the straightest path possible. See
“Determine vent path” in “Plan Vent System.” Avoid 90º turns.
Use clamps to seal all joints. Do not use duct tape, screws, or
other fastening devices that extend into the interior of the vent to
secure vent, because they can catch lint.
4. Screw the legs into the leg holes by hand. Use a wrench to finish
turning the legs until the diamond marking is no longer visible.
5. Place a carton corner post from dryer packaging under each of
the 2 dryer back corners. Stand the dryer up. Slide the dryer on
the corner posts until it is close to its final location. Leave enough
room to connect the exhaust vent or gas line.
For mobile home use
Gas dryers must be securely fastened to the floor.
Mobile home installations require a Mobile Home Installation Kit.
See “Tools and Parts” section for information on ordering.
Make Gas Connection
1. Remove the red cap from the gas pipe.
2. Using a wr
Use pipe-joint compound on the threads of all non-flared male
fittings. If flexible metal tubing is used, be sure there are no kinks.
ench to tighten, connect the gas supply to the dryer.
10
A. Flared male thread
B. Non-flared male thread
NOTE: For LP gas connections, you must use pipe-joint
compound resistant to the action of LP gas. Do not use
TEFLON
†
®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.
®†
tape.
A combination of pipe fittings must be used to connect the dryer
to the existing gas line. Shown is a recommended connection.
Your connection may be different, according to the supply line
type, size, and location.
A
B
A.3/8" flexible gas connector
3
/8" dryer pipe
B.
3
/8" to 3/8" pipe elbow
C.
3
D.
/8" pipe-to-flare adapter fitting
C
3. Open the shutoff valve in the supply line. The valve is open when
the handle is parallel to the gas pipe.
A
B
4. Using
pliers, tighten the couplings with an additional two-thirds
turn.
D
NOTE: Do not overtighten. Damage to the coupling can result.
5. Attach “Y” connector
to brass male end of small hose. Screw on
coupling by hand until it is seated on connector.
6. One end of the long hose has a wire mesh strainer inside the
coupling. Attach this end to the “Y” connector.
7. Attach washer cold inlet hose to ot
her end of “Y” connector.
Screw on coupling by hand until it is seated on connector.
8. Using
pliers, tighten the couplings with an additional two-thirds
turn.
A
A. Closed valve
B. Open valve
4. Test all connections by brushing on an approved noncorrosive
leak-detection solution. Bubbles will show a leak. Correct any leak
found.
Connect Vent
1. Using a 4" (102 mm) clamp, connect vent to exhaust outlet in
dryer. If connecting to existing vent, make sure the vent is clean.
The dryer vent must fit over the dryer exhaust outlet and inside the
exhaust hood. Check that the vent is secured to exhaust hood
with a 4" (102 mm) clamp.
ve dryer into its final location. Do not crush or kink vent.
2. Mo
3. Check that ther
e are no kinks in the flexible gas line.
4. Once the exhaust vent connection is made, remove the corner
posts and cardboard.
Connect Inlet Hose
The dryer must be connected to the cold water faucet using the new
inlet hoses. Do not use old hoses.
urn cold water faucet off and remove washer inlet hose.
1. T
2. Remove old rubber washer fr
rubber washer provided. If space permits, attach the brass female
end of the “Y” connector to the cold water faucet.
If “Y” connector can be attached directly to cold water
NOTE:
faucet, go to Step 6. If “Y” connector cannot be attached
directly to the cold water faucet, the short hose must be used.
Continue with Step 3.
3. A
ttach short hose to cold water faucet. Screw on coupling by
hand until it is seated on faucet.
om inlet hose and replace with new
A. Inlet to cold water
NOTE: Do not overtighten. Damage to the coupling can result.
tach other end of long hose to fill valve at bottom of dryer back
9. At
panel. Screw on coupling by hand until it is seated on fill valve
connector.
10. Using
pliers, tighten the coupling with an additional two-thirds
turn.
NOTE: Do not overtighten. Damage to the coupling can result.
eck that the water faucets are on.
11. Ch
eck for leaks around “Y” connector, faucet, and hoses.
12. Ch
11
Level Dryer
Check the levelness of the dryer by first placing a level on the top of
the dryer near the console.
3. Loosen the top screw from each of the 2 hinges in Step 2.
A
B
A
Then, by placing a level in the crease on the side of the dryer
between the top of the dryer and the dryer cabinet, check the
levelness from front to back.
If the dryer is not level, prop up the dryer using a wood block. Use a
wrench to adjust the legs up or down and check again for levelness.
Reverse Door Swing
You can change your door swing from a right-side opening to a leftside opening, if desired.
1. Place a towel or soft cloth on top of the dryer or work space to
avoid damaging the surface.
Remove the door assembly
1. Open the dryer door
2. Remove the
the dryer door to the front panel of the dryer.
.
bottom screw from each of the 2 hinges that attach
B
A. Loosen these screws.
B. Remove these screws.
4. Remove the dryer door and the hinges by lifting upward on the
door. Lay the door on a flat, protected surface, with the inside of
the door facing up. Remove remaining 2 loose screws from dryer
front panel.
5. Remove the 4 plastic plugs located outside the dryer door
opening.
6. Install 4 plastic plugs into screw holes in the dryer left where the
hinges were removed in Step 4.
12
Reverse the strike
A
A
1. Remove the door strike from the dryer door opening.
2. Remo
ve the cosmetic screw opposite the door strike.
B
A. Door strike
B. Cosmetic screw
3. Reinstall the door strike and cosmetic screw on the opposite side
of the dryer door opening from where they were removed.
NOTE: Door strike and plugs must be on the s
ame side of the
dryer door opening.
Reinstall the door
1. Remove the
4 screws and 2 hinges from the dryer door.
2. Replace the 4 screws in the same holes.
5. Install scr
ews in the top hinge holes in the door. Do not tighten
screws. Leave approximately ¼" (5 mm) of screw exposed.
A
A. Install these screws first.
6. Hang door by placing screw heads into top slotted holes of
hinges and slide door down. Align bottom screw holes in hinge
and door. Install two bottom screws. Tighten all hinge screws.
3. Remove the 4 screws from the opposite side of the door.
4. Install the 2 hinges to the front panel of the dryer using 4 screws.
Use the non-slotted side to attach the hinge to the front panel.
7. Close door to engage door strike.
Complete Installation
1. Check that all parts are now installed. If there is an extra part, go
back through the steps to see which step was skipped.
2. Ch
eck that you have all of your tools.
3. Dispose of/r
4. Be su
eck for leaks around “Y” connector, faucet, and hoses.
5. Ch
eck the dryer’s final location. Be sure the vent is not crushed or
6. Ch
kinked.
ecycle all packaging materials.
re the water faucets are on.
13
7. Check that the dryer is level. See “Level Dryer.”
WARNING
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
re, or electrical shock.
8. Plug into a grounded 3 prong outlet. Turn on power.
9. Remo
10. Read “Dryer Use.”
11. Wipe the dry
ve any film or tape remaining on the dryer.
NOTE: G
lass door models have a film on the window that
should be removed.
er drum interior thoroughly with a damp cloth to
remove any dust.
12. If you live in a har
d water area, use of a water softener is
recommended to control the buildup of scale through the water
system in the dryer. Over time, the buildup of lime scale may clog
different parts of the water system, which will reduce product
performance. Excessive scale buildup may lead to the need for
certain part replacement or repair.
13. Test dryer operation by selecting a Timed Dry heated cycle and
starting the dryer. For this test, do not select the Air Only modifier.
If the dryer
■ Dryer is plugged into a grounded 3 prong outlet.
■ Electrical supply is connected.
■ Household fuse is intact and tight, or circuit breaker has not
will not start, check the following:
tripped.
■ Dryer door is closed.
14. When the dryer has been running for 5 minutes, open the dryer
door and feel for heat. If you feel heat, cancel cycle and close
door. If you do not feel heat, turn off the dryer and check that the
gas supply line shutoff valve is open.
■ If the gas supply line shutoff valve is closed, open it, then
repeat the 5-minute test as outlined above.
■ If the gas supply line shutoff valve is open, contact a
qualified technician.
14
DRYER USE
Starting Your Dryer
WARNING
Explosion Hazard
Keep ammable materials and vapors, such as
gasoline, away from dryer.
Do not dry anything that has ever had anything
ammable on it (even after washing).
Failure to follow these instructions can result in death,
explosion, or re.
This manual covers several different models. Your dryer may not
have all of the cycles and features described.
Follow these basic steps to start your dryer. Please refer to
speci
fic sections of this manual for more detailed information.
1. Clean lint screen before each load. See “Cleaning the Lint
Screen.”
2. Place laun
ess POWER.
3. Pr
urn the knob to the selected cycle. The preset settings for
4. T
Automatic Cycles or Timed Cycles will illuminate. The estimated
(automatic cycle) or actual (timed) cycle time (in minutes) will show
in the display.
NOTE: A de
selected. During the first few minutes of the drying process,
the cycle time may automatically vary from the default time
based on the size and fabric type of the load. Toward the end
of the drying process, the estimated time display will adjust
again, showing the final drying time.
To use an Automatic Cycle
■ Press POWER.
■ Turn the knob to desired Automatic Cycle.
dry into dryer and shut door.
fault time is displayed when an automatic cycle is
WARNING
Fire Hazard
No washer can completely remove oil.
Do not dry anything that has ever had any type of oil on
it (including cooking oils).
Items containing foam, rubber, or plastic must be dried
on a clothesline or by using an Air Cycle.
Failure to follow these instructions can result in death
or re.
■ Select DRYNESS to adjust how dry you want the load. As
the cycle runs, the control senses the dryness of the load
and adjusts the time automatically for the selected dryness
level.
The default dryness setting is Normal when an Automatic
Cyc
le is selected. You can select a different dryness level,
depending on your load, by pressing Dryness and
choosing More, Less, or Damp. Selecting More, Less, or
Damp automatically adjusts the sensed time needed.
Once a dryness level is set, it cannot be changed without
stopping the cycle.
■ Select the desired Options.
To make changes during an
■ Press PAUSE/CANCEL.
Automatic Cycle:
15
■ Adjust Dryness.
NOTE: Dryness selections can be made only while using
Automatic Cycles.
How the AccelerCare
Moisture-sensing strips and temperatur
®
Drying System Works
e sensors inside the
dryer drum monitor how fast the load is drying, how hot the air
should be and when clothes are dry. The system automatically
stops the cycle to help save time and avoid overdrying.
To use a Timed Cycle
■ Turn knob to desired Timed Cycle.
■ Press the TIME ADJUST up or down arrows until the
desired drying time is displayed. Press the up or down
arrows and the time will change by 1-minute intervals.
Press and hold the up or down arrows and the time will
change by 5-minute intervals.
NOTE: The Time Adjust features can be used only with
the Timed Dry and the Enhanced Touch Up cycles.
■ Press the TIME ADJUST up or down arrows until the desired
drying time is displayed. Press the up or down arrows and
the time will change by 1-minute intervals. Press and hold
the up or down arrows and the time will change by 5-minute
intervals.
NOTE:
The Time Adjust features can be used only with
the Timed Dry and the Enhanced Touch Up cycles.
■ Press TEMP until the desired temperature illuminates.
NOTE: The Temp feature can be used only with the Timed
Dry and the Enhanced Touch Up cycles. Only the Medium
and High temperature settings can be used for the
Enhanced Touch Up Cycle.
NOTE: D
uring the Enhanced Touch Up cycle, you can change
the settings for Time Adjust and Temp. Open the door or press
PAUSE/CANCEL once to pause the cycle, or press PAUSE/
CANCEL twice to cancel a cycle.
■ Press TEMP until the desired temperature illuminates.
NOTE: The Temp feature can be used only with the Timed
Dry and the Enhanced Touch Up cycles.
NOTE:
During the Timed Dry Cycle, you can change the
settings for Time, Temp, the WRINKLE SHIELD™ setting, and
the End of Cycle Signal.
5. (O
PTIONAL STEP) If desired, select OPTIONS. For more details,
see “Options.”
TIONAL STEP) If desired, press END OF
6. (OP
CYCLE SIGNAL. A
signal will sound to alert you when a cycle ends. For more details,
see “End of Cycle Signal.”
7. Press START. Be sure the door is closed.
■ If you do not press Start within 5 minutes of selecting the
cycle, the dryer automatically shuts off.
■ If you wish to end your drying cycle after pressing Start,
press PAUSE/CANCEL twice.
To use a Steam Cycle
(Quick Refresh and Enhanced T
■ Press POWER.
■ Turn the knob to select either the Enhanced Touch Up or
ouch Up)
the Quick Refresh cycles.
Stopping, Pausing, or Restarting
To stop or pause your dryer at any time
Open the door or press PAUSE/CANCEL once. Press PAUSE/
CANCEL twice to cancel a cycle.
To restart the dryer
Close the door. Press START until dryer starts.
NOTE:
if you close the door and press Start within 5 minutes. If the cycle
is interrupted for more than 5 minutes, the dryer will shut off.
Select new cycle settings before restarting the dryer.
Drying will continue from where the cycle was interrupted
Drying and Cycle Tips
Select the correct cycle and dryness level or temperature for your
load. If an Automatic Cycle is running, the display shows the
estimated cycle time when your dryer is automatically sensing the
dryness level of your load. If a Timed Cycle is running, the display
shows the exact number of minutes remaining in the cycle.
Cool Down tumbles the load without
minutes of all cycles. Cool Down makes the loads easier to handle
and reduces wrinkling. The length of the Cool Down depends on the
load size and dryness level.
Drying tips
■ Follow care label directions when they are available.
■ If desired, add a fabric softener sheet. Follow package
instructions.
■ To reduce wrinkling, remove the load from the dryer as soon as
tumbling stops. This is especially important for permanent
press, knits, and synthetic fabrics.
■ Avoid drying heavy work clothes together with lighter fabrics.
This could cause overdrying of lighter fabrics and lead to
increased shrinkage or wrinkling.
heat during the last few