Whirlpool WFW9500T User Manual

®
Duet Washer
PRODUCT MODEL NUMBERS OVERALL DIMENSIONS
DRAIN SYSTEM OPTIONS
WFW9500T
Electrical: 120-volt, 60 Hz, AC-only, 15 or 20 amp electrical supply. A time-delay fuse or circuit breaker is recommended. It is recommended that a separate circuit serving only this appliance be provided.
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
Ref. W10158196
02-08-08
UNDERCOUNTER INSTALLATION
(
)
( )
6
Recessed or Closet Installation Washer on Pedestal
Dimensions shown are for minimum spacing.
Standpipe drain system - wall or floor (view A & B)
The standpipe drain requires a minimum diameter standpipe of 2" (5 cm). The minimum carry-away capacity can be no less than 17 gal. (64 L) per minute.
The top of the standpipe must be at least 30" (76.2 cm) high and no higher than 96" (2.4 m) from the bottom of the washer.
Laundry tub drain system (view C)
The laundry tub needs a minimum 20 gal. (76 L) capacity. The top of the laundry tub must be at least 30" (76.2 cm) above the floor.
Floor drain system (view D)
The floor drain system requires a siphon break that may be purchased separately.
The siphon break must be a minimum of 28" (71 cm) from the bottom of the washer. Additional hoses might be needed.
*Min. top and
bottom air openings for closet door.
**External exhaust
elbow requires additional space.
***Wall, door amd
floor molding may require additional spacing.
Stacked Washer and Dryer
Recommended installation spacing for cabinet installation
For cabinet installation, with a door, the minimum ventilation openings in the top are required.
RECESSED AREA AND CLOSET INSTALLATIONS
For closet installation, with a door, the minimum ventilation openings in the top and bottom of the door are required (view 2). Louvered doors with equivalent air ventilation openings in the top and bottom are acceptable.
AB
A. Recessed area B. Side view — closet or confined area
AB
CD
"
(7.6 cm)
"
(7.6 cm)
1"
(2.5 cm)
(
86.4
31 ¹⁄₂"
(80 cm)
34
"
cm)
4"
(10.2 cm)
2
48 in.
(310 cm
2
24 in.
(155 cm
*
2
)
*
2
)
AB
A. Side view - closet or confined area B. Closet door with vents
1"
(2.5 cm)
48 in.2 *
(310 cm
27"
(68.6 cm)
2
)
39" min
(99.0 cm)
1"
(2.5 cm)
27"
(68.6 cm)
1"
(2.5 cm)
24 in.
155 cm
2
*
2
18 min."
(45.7 cm)
31¹⁄₂ "
1"
(2.5 cm)
1"
(2.5 cm)
(80 cm)
4"
(10.2 cm)
3" (7.6 cm)
3" (7.6 cm)
1" (2.5 cm)
27"
51"
(129.5 cm)
(68.6 cm)
31¹⁄₂"
(80.0 cm)
38"
(96.5 cm)
5¹⁄₂"**
(14 cm)
7" (17.8 cm)
7" (17.8 cm)
4"
(1
0.2 cm
" (15.2 cm)
76"
193 cm)
1"***
(2.5 cm)
31¹⁄₂"
)
27"
(68.6 cm)
1"
(2.5 cm)1"(2.5 cm)
(2.5 cm)
1"***
9" (22.9 cm)
27"
1"
(2.5 cm)
30" min.
(76.2 cm)
28" min.
30" min.
(76.2 cm)
(71 cm)