INSTALLATIONINSTRUCTIONS
30" (76.0 CM) FREESTANDINGGAS RANGES
INSTRUCTIONSD'INSTALLATIONDESCUISINIERESA GAZ
AUTOPORTANTESDE30" (76,0 CM)
Table of Contents/Table des mati_res
RANGE SAFETY ............................................................................. 2
INSTALLATION REQUIREMENTS ................................................ 3
Tools and Parts ............................................................................ 3
Location Requirements ................................................................ 3
Electrical Requirements ............................................................... 5
Gas Supply Requirements ........................................................... 5
INSTALLATION INSTRUCTIONS .................................................. 7
Unpack Range .............................................................................. 7
Install Anti-Tip Bracket ................................................................. 7
Make Gas Connection ................................................................. 8
Verify Anti-Tip Bracket Location .................................................. 9
Level Range .................................................................................. 9
Electronic Ignition System ......................................................... 10
Complete Installation ................................................................. 11
GAS CONVERSIONS .................................................................... 12
LP Gas Conversion .................................................................... 12
Complete Conversion ................................................................ 13
Natural Gas Conversion ............................................................. 14
Complete Conversion ................................................................ 15
SI_CURITI_ DE LA CUISINII_RE ................................................... 16
EXIGENCES D'INSTALLATION ................................................... 18
Outillage et composants ............................................................ 18
Exigences d'emplacement ......................................................... 18
Specifications electriques .......................................................... 20
Specifications de I'alimentation en gaz ..................................... 20
INSTRUCTIONS D'INSTALLATION ............................................. 22
Deballage de la cuisiniere .......................................................... 22
Installation de la bride antibasculement .................................... 22
Raccordement au gaz ................................................................ 23
Verification de I'emplacement de la bride antibasculement ......25
Reglage de I'aplomb de la cuisiniere ......................................... 25
Systeme d'allumage electronique .............................................. 25
Achever I'installation .................................................................. 27
CONVERSIONS POUR CHANGEMENT DE GAZ ....................... 28
Conversion pour I'alimentation au propane ............................... 28
Terminer la conversion ............................................................... 30
Conversion pour I'alimentation au gaz naturel .......................... 30
Terminer la conversion ............................................................... 32
iMPORTANT:
Save for local electrical inspector's use.
iMPORTANT :
,&,conserver pour consultation par I'inspecteur local des installations 61ectriques.
W10200946A
RANGESAFETY
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word "DANGER" or "WARNING."
These words mean:
You can be killed or seriously injured if you don't immediately
follow instructions.
You can be killed or seriously injured if you don't follow
instructions.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can
happen if the instructions are not followed.
WARNING: If the information in this manual is not followed exactly, a fire or explosion
may result causing property damage, personal injury or death,
- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this
or any other appliance,
- WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electrical switch.
• Do not use any phone in your building.
• Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier, call the fire department.
- Installation and service must be performed by a qualified installer, service agency or
the gas supplier,
WARNING: Gas leaks cannot always be detected by smell.
Gas suppliers recommend that you use a gas detector approved by UL or CSA.
For more information, contact your gas supplier.
If a gas leak is detected, follow the "What to do if you smell gas" instructions.
In the State of Massachusetts, the following installation instructions apply:
m Installations and repairs must be performed by a qualified or licensed contractor, plumber, or gasfitter qualified or licensed by
the State of Massachusetts.
m If using a ball valve, it shall be a T-handle type.
m A flexible gas connector, when used, must not exceed 3 feet.
2
A child or adult can tip the range and be killed.
Connect anti=tip bracket to rear range foot.
Reconnect the anti=tip bracket, if the range is moved.
Failure to follow these instructions can result in death or serious burns to children and adults.
INSTALLATIONREQUIREMENTS
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed
here.
Tip Over Hazard
Parts needed
Check local codes and consult gas supplier. Check existing gas
supply and electrical supply. See "Electrical Requirements" and
"Gas Supply Requirements" sections.
Tools Needed
• Level
• 3/8"drive ratchet
• Tape measure
• Flat-blade screwdriver
• Phillips screwdriver
• Hand or electric drill
• Wrench or pliers
• 7 mm combination wrench
• Pipe wrench
• V8"(3.2 mm) drill bit (for wood floors)
• 3/16"(4.8 ram) carbide-tipped masonry drill bit (for concrete/
ceramic floors)
• Pipe-joint compound resistant to LP gas
• Noncorrosive leak-detection solution
Parts supplied
Check that all parts are included.
B
C
A. Anti-tip bracket
B. Plastic anchors (2)
C. #10 x 1/_,,screws (2)
• Bag containing literature.
• Conversion orifice spuds (inside bag containing literature).
• Anti-tip bracket must be securely mounted to subfloor.
Thickness of flooring may require longer screws to anchor
bracket to subfloor. Longer screws are available from your
local hardware store.
IMPORTANT: Observe all governing codes and ordinances. Do
not obstruct flow of combustion and ventilation air.
• It is the installer's responsibility to comply with installation
clearances specified on the model/serial rating plate. The
model/serial rating plate is located on the oven frame behind
the left side of the broiler door.
A
A. Model/serial rating plate location
The range should be located for convenient use in the
kitchen.
Recessed installations must provide complete enclosure of
the sides and rear of the range.
To eliminate the risk of burns or fire by reaching over heated
surface units, cabinet storage space located above the
surface units should be avoided. If cabinet storage is to be
provided, the risk can be reduced by installing a range hood
that projects horizontally a minimum of 5" (12.7 cm) beyond
the bottom of the cabinets.
All openings in the wall or floor where range is to be installed
must be sealed.
Do not seal the range to the side cabinets.
Cabinet opening dimensions that are shown must be used.
Given dimensions are minimum clearances.
The floor anti-tip bracket must be installed. To install the anti-
tip bracket shipped with the range, see "Install Anti-Tip
Bracket" section.
• Grounded electrical supply is required. See "Electrical
Requirements" section.
• Proper gas supply connection must be available. See "Gas
Supply Requirements" section.
• Contact a qualified floor covering installer to check that the
floor covering can withstand at least 200°F (93°C).
• Useaninsulatedpador1¼,,(0.64cm)plywoodunderrangeif
installingrangeovercarpeting.
IMPORTANT:Toavoiddamagetoyourcabinets,checkwithyour
builderorcabinetsuppliertomakesurethatthematerialsused
willnotdiscolor,delaminateorsustainotherdamage.Thisoven
hasbeendesignedinaccordancewiththerequirementsofUL
andCSAInternationalandcomplieswiththemaximumallowable
woodcabinettemperaturesof194°F(90°C).
Mobile Home - Additional Installation Requirements
The installation of this range must conform to the Manufactured
Home Construction and Safety Standard, Title 24 CFR, Part 3280
(formerly the Federal Standard for Mobile Home Construction
and Safety, Title 24, HUD Part 280). When such standard is not
applicable, use the Standard for Manufactured Home
Installations, ANSI A225.1/NFPA 501A or with local codes.
In Canada, the installation of this range must conform with the
current standards CAN/CSA-A240 - latest edition, or with local
codes.
Mobile home installations require:
• When this range is installed in a mobile home, it must be
secured to the floor during transit. Any method of securing
the range is adequate as long as it conforms to the standards
listed above.
Product Dimensions
Cabinet Dimensions
Cabinet opening dimensions shown are for 25" (64.0 cm)
countertop depth, 24" (61.0 cm) base cabinet depth and
36" (91.4 cm) countertop height.
If the cabinet depth is greater than 24" (61.0 cm), oven frame
must extend beyond cabinet fronts by 1/2"(13.0 mm) minimum.
IMPORTANT: If installing a range hood or microwave hood
combination above the range, follow the range hood or
microwave hood combination installation instructions for
dimensional clearances above the cooktop surface.
A
C
A. 36" (91.4 cm)
B. 29 z_,,(75.9 cm)
C. 24¼" (61.6 cm)
D. 253/4" (65.6 cm)
E.46¼" (117.5 cm)
E
A. 18" (45.7 cm) min. clearance upper side cabinet to countertop
B. 13" (33.0 cm) max. upper cabinet depth
C. 30" (76.2 cm) min. cabinet opening width
D. For minimum clearance to top of cooktop, see NOTE*.
E.30%" (76.5 cm) min. opening width
F. This shaded area recommended for installation of electrical outlet.
G. This shaded area recommended for installation of rigid gas pipe.
H. 2" (5.1 cm) min. countertop space to side wall or other combustible
material
I. 24" (61.0 cm)
J. 10" (25.4 cm)
K. 8" (20.3 cm)
L. 5" (12. 7 cm)
M. 2" (5.1 cm)
N. 3" (7.6 cm)
*NOTE: 24" (61.0 cm) minimum when bottom of wood or metal
cabinet is covered by not less than 1/4"(0.64 cm) flame retardant
millboard covered with not less than No. 28 MSG sheet steel,
0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum or
0.020" (0.5 mm) copper.
30" (76.2 cm) minimum clearance between the top of the
cooking platform and the bottom of an uncovered wood or metal
cabinet.
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
IMPORTANT: The range must be electrically grounded in
accordance with local codes and ordinances, or in the absence
of local codes, with the National Electrical Code, ANSI/NFPA 70,
latest edition.
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrical installer determine that
the ground path is adequate.
A copy of the above code standards can be obtained from:
National Fire Protection Association
One Batterymarch Park
Quincy, MA 02269
CSA International
8501 East Pleasant Valley Road
Cleveland, OH 44131-5575
• A 120 volt, 60 Hz., AC only, 15-amp fused, electrical circuit is
required. A time-delay fuse or circuit breaker is also
recommended. It is recommended that a separate circuit
serving only this range be provided.
• This range is equipped with a power supply cord having a
3 prong ground plug. To minimize possible shock hazard the
cord must be plugged into a grounded 3 prong outlet.
• Electronic ignition systems operate within wide voltage limits,
but proper grounding and polarity are necessary. Check that
the outlet provides 120-volt power and is correctly grounded.
This range is equipped with an electronic ignition system that
will not operate if plugged into an outlet that is not properly
polarized.
• The wiring diagram is located on the back of the range in a
clear plastic bag.
NOTE: The metal chassis of the range must be grounded in
order for the control panel to work. If the metal chassis of the
range is not grounded, no keypads will operate. Check with a
qualified electrician if you are in doubt as to whether the
metal chassis of the range is grounded.
Explosion Hazard
Use a new CSA international approved gas supply line.
install a shut=off valve.
Securely tighten all gas connections.
if connected to LP, have a qualified person make sure
gas pressure does not exceed 14" (36 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
Observe all governing codes and ordinances.
IMPORTANT: This installation must conform with all local codes
and ordinances. In the absence of local codes, installation must
conform with American National Standard, National Fuel Gas
Code ANSI Z223.1 - latest edition or CAN/CGA B149 - latest
edition.
IMPORTANT: Leak testing of the range must be conducted
according to the manufacturer's instructions.
Type of Gas
Natural gas:
This range is design-certified by CSA International for use with
Natural gas or, after proper conversion, for use with LP gas.
• This range is factory set for use with Natural gas. See "Gas
Conversions" section. The model/serial rating plate located
behind the broiler door on the left-hand side oven door frame
has information on the types of gas that can be used. If the
types of gas listed do not include the type of gas available,
check with the local gas supplier.
LP gas conversion:
Conversion must be done by a qualified service technician.
No attempt shall be made to convert the appliance from the gas
specified on the model/serial rating plate for use with a different
gas without consulting the serving gas supplier. See "Gas
Conversions" section.
Gas Supply Line
Gas Pressure Regulator
Provide a gas supply line of 3_,,(1.9 cm) rigid pipe to the
range location. A smaller size pipe on longer runs may result
in insufficient gas supply. Pipe-joint compounds that resist
the action of LP gas must be used. Do not use TEFLON ®t
tape. With LP gas, piping or tubing size can be 1/2"(1.3 cm)
minimum. Usually, LP gas suppliers determine the size and
materials used in the system.
Flexible metal appliance connector:
• If local codes permit, a new CSA design-certified,
4 to 5 ft (122 to 152.4 cm) long, 1/2"(1.3 cm) or
3_,,(1.9 cm) I.D., flexible metal appliance connector may
be used for connecting range to the gas supply line.
• A 1/2"(1.3 cm) male pipe thread is needed for connection
to the female pipe threads of the inlet to the appliance
pressure regulator.
• Do not kink or damage the flexible metal tubing when
moving the range.
Rigid pipe connection:
The rigid pipe connection requires a combination of pipe
fittings to obtain an in-line connection to the range. The rigid
pipe must be level with the range connection. All strains must
be removed from the supply and fuel lines so range will be
level and in line.
Must include a shutoff valve:
The supply line must be equipped with a manual shutoff
valve. This valve should be located in the same room but
external to the range. It should be in a location that allows
ease of opening and closing. Do not block access to shutoff
valve. The valve is for turning on or shutting off gas to the
range.
B
The gas pressure regulator supplied with this range must be
used. The inlet pressure to the regulator should be as follows for
proper operation:
Natural gas:
Minimum pressure: 5" WCP
Maximum pressure: 14" WCP
LP gas:
Minimum pressure: 11" WCP
Maximum pressure: 14" WCP
Contact local gas supplier if you are not sure about the inlet
pressure.
Burner Input Requirements
Input ratings shown on the model/serial rating plate are for
elevations up to 2,000 ft (609.6 m).
For elevations above 2,000 ft (609.6 m), ratings are reduced at a
rate of 4% for each 1,000 ft (304.8 m) above sea level (not
applicable for Canada).
Gas Supply Pressure Testing
Gas supply pressure for testing regulator must be at least
1" water column pressure above the manifold pressure shown on
the model/serial rating plate.
Line pressure testing above 1/2psi gauge (14" WCP)
The range and its individual shutoff valve must be disconnected
from the gas supply piping system during any pressure testing of
that system at test pressures in excess of 1/2psi (3.5 kPa).
Line pressure testing at 1/2psi gauge (14" WCP) or lower
The range must be isolated from the gas supply piping system by
closing its individual manual shutoff valve during any pressure
testing of the gas supply piping system at test pressures equal to
or less than 1/2psi (3.5 kPa).
A. Gas supply fine
B. Shutoff valve "open" position
C. To range
t®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.
6
INSTALLATIONINSTRUCTIONS
Excessive Weight Hazard
Use two or more people to move and install range.
Failure to do so can result in back or other injury.
1. Do not use oven door handle to lift or move the range
2. Remove shipping materials, tape and film from range. Keep
cardboard bottom under range.
3. Remove oven racks and parts package from inside oven.
4. To place range on its back, take 4 cardboard corners from the
carton. Stack one cardboard corner on top of another.
Repeat with the other 2 corners. Place them lengthwise on
the floor behind the range to support the range when it is laid
on its back.
5. Using 2 or more people, firmly grasp the range and gently lay
it on its back on the cardboard corners.
6. Pull cardboard bottom firmly to remove.
7. Use an adjustable wrench to loosen the leveling legs. Adjust
the leveling legs to the correct height. Leveling legs can be
loosened to add up to a maximum of 1" (2.5 cm). A minimum
of 3/le" (0.5 cm) is needed to engage the anti-tip bracket.
NOTE: If height adjustment is made when range is standing, tilt
the range back to adjust the front legs, then tilt forward to adjust
the rear legs.
8. Place cardboard or hardboard in front of range. Using 2 or
more people, stand range back up onto cardboard or
hardboard.
2. Place template on the floor in cabinet opening so that the left
edge is against cabinet and top edge is against rear wall,
molding or cabinet.
3. Tape template into place.
4. If countertop is not flush with cabinet opening edge, align
template with overhang.
m
If cabinet opening is wider than that specified in the "Location
Requirements" section, adjust template so range will be
centered in cabinet opening.
5.
To mount anti-tip bracket to wood floor, drill two 1/8"(0.32 cm)
holes at the positions marked on the bracket template.
Remove template from floor and move to Step 7.
To mount the anti-tip bracket to a concrete or ceramic floor,
use a 3/le"(0.5 cm) masonry drill bit to drill 2 holes at the
positions marked on the bracket template. Remove the
template from the floor.
I
f"sskx A' BKsc<e't
Tip Over Hazard
A child or adult can tip the range and be killed.
Connect anti=tip bracket to rear range foot.
Reconnect the anti=tip bracket, if the range is moved.
Failure to follow these instructions can result in death
or serious burns to children and adults.
Contact a qualified floor covering installer for the best procedure
for drilling mounting holes through your type of floor covering.
Before moving range, slide range onto shipping base, cardboard
or hardboard.
1. Remove template from the anti-tip bracket kit (found inside
the oven cavity).
6. Tap plastic anchors into holes with a hammer.
7. Align the anti-tip bracket holes with the holes in the floor.
Fasten the anti-tip bracket with the screws provided.
Depending on the thickness of your flooring, longer screws
may be necessary to anchor the bracket to the subfloor.
Longer screws are available from your local hardware store.
8.
Move range close enough to the opening to allow for final
electrical connection. Remove shipping base, cardboard or
hardboard from under range.
9. Openthebroilerdoor.Usea3/8"driveratchettolowertherear
levelinglegsone-halfturn.Useawrenchorplierstolowerthe
frontlevelingletsone-halfturn.
2=
Using a pipe wrench to tighten, connect the gas supply to the
range.
C
B
A. Rear leveling leg
B. Front leveling leg
10. Adjust the leveling legs to the correct height. Leveling legs
can be loosened to add up to a maximum of 1" (2.5 cm). A
minimum of 3Ad' (0.5 cm) is needed to engage the anti-tip
bracket.
11. Move range into its final location making sure rear leveling leg
slides into anti-tip bracket.
12. If installing the range in a mobile home, you must secure the
range to the floor. Any method of securing the range is
adequate as long as it conforms to the standards in the
"Location Requirements" section.
13. Continue installing your range using the following installation
instructions.
] .....................D
G ...........................................
A. Pressure regulator
connection fitting
B. 90 ° elbow
C. Black iron pipe
D. Union
E.Nipple
F Manual shutoff valve
G. Y2"or 3/4"gas pipe
Typical flexible connection
1. Apply pipe-joint compound made for use with LP gas to the
smaller thread ends of the flexible connector adapters (see B
and F in the following illustration).
2. Attach one adapter to the gas pressure regulator and the
other adapter to the gas shutoff valve. Tighten both adapters.
3. Use a combination wrench and pliers to attach the flexible
connector to the adapters. Check that connector is not
kinked.
A
...................................................................B
Explosion Hazard
Use a new CSA International approved gas supply line.
install a shut=off valve.
Securely tighten all gas connections.
if connected to LP, have a qualified person make sure
gas pressure does not exceed 14" (36 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
Typical rigid pipe connection
A combination of pipe fittings must be used to connect the range
to the existing gas line. Your connections may be different,
according to the supply line type, size and location.
1. Apply pipe-joint compound made for use with LP gas to all
pipe thread connections.
A. Pressure regulator
connection fitting
B. Use pipe-joint compound
C. Adapter
D. Flexible connector
............ D
[]
E ......... ...................
H ...............................
L,d
E.Adapter
F Use pipe-joint compound
G. Manual shutoff valve
H. Y2"or 3/4"gas pipe
F
G
8
CompleteConnection
1. Locate gas pressure regulator inthe broiler.
IMPORTANT: Do not remove the gas pressure regulator.
2. Check that the gas pressure regulator shutoff valve is in the
"on" position.
3. Open the manual shutoff valve in the gas supply line. The
valve is open when the handle is parallel to the gas pipe.
A. Closed valve
B. Open valve
6.
Remove cooktop burner caps and grates from parts
package. Align notches in burner caps with pins in burner
base. Burner caps should be level when properly positioned.
If burner caps are not properly positioned, surface burners
will not light. Place burners, burner caps and grates on the
cooktop.
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
7. Plug into a grounded 3 prong outlet.
Bc: cke$
1.
Check that the anti-tip bracket is installed:
• Look for the anti-tip bracket securely attached to the
floor.
• Slide the range back so the rear range foot is under the
anti-tip bracket.
4. Test all connections by brushing on an approved
noncorrosive leak-detection solution. Bubbles will show a
leak. Correct any leak found.
5. Close the broiler door.
1.
Place rack in oven.
2.
Place level on rack and check levelness of range, first side to
side; then front to back.
3. If range is not level, pull range forward until rear leveling leg is
removed from the anti-tip bracket. Use 3/8"drive ratchet and
wrench or pliers to adjust leveling legs up or down until range
is level.
4. Push range back into position.
5. Check that rear leveling leg is engaged in anti-tip bracket.
NOTE: Range must be level for satisfactory baking performance.
Initial lighting and gas flame adjustments
Cooktop and oven burners use electronic igniters in place of
standing pilots. When the cooktop control knob is turned to the
"LITE" position, the system creates a spark to light the burner.
This sparking continues until the control knob is turned to the
desired setting.
When the oven control is turned to the desired setting, a hot
surface igniter heats to a bright orange and ignites the gas. No
sparking occurs. The glow bar remains on while the burner
operates.
Check Operation of Cooktop Burners
1. If control panel and knobs were removed earlier, reinstall
knobs.
2. Push in and turn each surface unit control knob to "LITE"
position. The flame should light within 4 seconds.
eo 01
oo
If the low flame needs adjusting:
1. Turn control knob to the "Lo" setting and remove control
knob.
2. Insert a small flat-blade screwdriver into the valve stem. Turn
the valve adjusting screw to obtain the smallest flame that will
not go out when the control of a cold burner is quickly turned
from "HI" to "Lo." Turn right to decrease flame height. Turn
left to increase flame height. Repeat for other cooktop
burners as needed.
A. Valve stem
LITE
LO
MED
3.
Turn control knob to "HI" position after burner lights.
4.
Check each cooktop burner for proper flame. The small inner
once should have a very distinct blue flame 1¼,,(0.64 cm) to
1/2"(0.13 cm) long. The outer cone is not as distinct as the
inner cone.
A. Outer cone
B. Inner cone
5. Turn the control knob quickly to the "LO" position after the
burner lights. If the flame goes out, turn the control knob to
the "OFF" position.
6. Check each cooktop burner for proper low flame. The low
flame should be a minimum, steady blue flame. The flame
size should be W' to 3/8' (0.64 cm to 0.95 cm) high.
3. Replace control knob.
Check Operation of Oven/Broil Burner
Electronic oven control (on some models):
1. Open broiler door.
2. Press the "BAKE" pad.
• The "BAKE" indicator will light.
• "350" will appear in the display.
3. Press the START/ENTER pad.
• The "TEMP" and "ON" indicators will appear.
• The display will show the automatic countdown time
(10 minutes) needed to preheat the oven for selected
temperature.
• The oven burner should light in 20-40 seconds; this delay
is normal. The oven valve requires a certain time before it
will open and allow gas to flow. The oven burner will burn
until oven temperature has reached 350°F (177°C). After
20-40 seconds, the oven burner will begin to cycle on and
off to maintain the 350°F (177°C) temperature.
Broil burner and oven burner are the same burner. Check the broil
function as follows:
1. Press the "BROIL" pad.
• "525" will appear in the display.
• The "BROIL" indicator will light.
2. Press the START/ENTER pad.
• The oven burner should light in 20-40 seconds; this delay
is normal. The oven valve requires a certain time before it
will open and allow gas to flow.
To avoid damaging the hot surface igniter, do not insert any
object into the openings of the shield that surrounds the
igniter or clean that area.
3. Check the oven burner for proper flame. The flame should be
1/2"(0.13 cm) long, with inner cone of bluish-green. The outer
mantle should be dark blue and should be clean and soft in
character. No yellow tips (not enough air), blowing or lifting
(too much air) of flame should occur.
10