30" (76 cm) Freestanding Gas Range
PRODUCT MODEL NUMBERS
PRODUCT DIMENSIONS
WFG231LV
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. W10477539B
8/13/13
Gas Supply Line
●
Provide a gas supply line of ³⁄₄" (1.9 cm) rigid pipe to the range location. A smaller
size pipe on longer runs may result in insufficient gas supply. With LP gas, piping or
tubing size can be ¹⁄₂" (1.3 cm) minimum. Usually, LP gas suppliers determine the
size and materials used in the system.
NOTE: Pipe-joint compounds that resist the action of LP gas must be used. Do not
use TEFLON
®†
tape.
Flexible metal appliance connector:
●
If local codes permit, a new CSA design-certified, 4 to 5 ft (122 to 152.4 cm) long, ¹⁄₂"
(1.3 cm) or ³⁄₄" (1.9 cm) I.D., flexible metal appliance connector may be used for
connecting range to the gas supply line.
●
A ¹⁄₂" (1.3 cm) male pipe thread is needed for connection to the female pipe threads of
the inlet to the appliance pressure regulator.
●
Must include a shutoff valve:
The supply line must be equipped with a manual shutoff valve. This valve should be
located in the same room but external to the range opening, such as an adjacent
cabinet. It should be in a location that allows ease of opening and closing. Do not
block access to shutoff valve. The valve is for turning on or shutting off gas to the
range.
Electrical: A 120-volt, 60 Hz, AC-only, 15 amp, fused electrical circuit is required. A
time-delay fuse or circuit breaker is also recommended. It is recommended that a
separate circuit serving only this range be provided.
†®
TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.
CABINET OPENING DIMENSIONS
Cabinet opening dimensions shown are for 25" (64.0 cm) countertop depth, 24"
(61.0 cm) base cabinet depth and 36" (91.4 cm) countertop height.
If the cabinet depth is greater than 24" (61.0 cm), oven frame must extend beyond
cabinet fronts by ¹⁄₂" (13.0 mm) minimum.
IMPORTANT: If installing a range hood or microwave hood combination above the
range, follow the range hood or microwave hood combination installation instructions
for dimensional clearances above the cooktop surface.
*NOTE: 24" (61.0 cm) minimum when bottom of wood or metal cabinet is covered by
not less than ¹⁄₄" (0.64 cm) flame retardant millboard covered with not less than
No. 28 MSG sheet steel, 0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum
or 0.020" (0.5 mm) copper.
30" (76.2 cm) minimum clearance between the top of the cooking platform and the
bottom of an uncovered wood or metal cabinet.
B
A
A. Gas supply line
B. Shutoff valve “open” position
C. To range
C
A
B
A. 36" (91.4 cm)
⁷⁄₈
" (75.9 cm)
B. 29
C. 24¼" (61.6 cm)
D. 25¾" (65.6 cm)
E. 46¼" (117.5 cm)
D
E
C
A. 18" (45.7 cm) min. clearance upper side cabinet to countertop
B. 13" (33.0 cm) max. upper cabinet depth
C. 30" (76.2 cm) min. cabinet opening width
D. For minimum clearance to top of cooktop, see NOTE*.
" (76.5 cm) min. opening width
E. 30
¹⁄₈
F. This shaded area recommended for installation of electrical outlet.
G. This shaded area recommended for installation of rigid gas pipe.
H. 2" (5.1 cm) min. countertop space to side wall or other combustible
material
I. 24" (61.0 cm)
J. 10" (25.4 cm)
K. 8" (20.3 cm)
L. 5" (12.7 cm)
M. 2" (5.1 cm)
N. 3" (7.6 cm)
B
D
C
A
E
H
I
F
L
N
G
J
K
M
L